Service Manual
4
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes
TROUBLESHOOTING GUIDE
Malfunction Probable Cause Corrective Action
Prompt persists and
information entry not
allowed.
Attempting to enter improper
duration of time.
Refer to Operation Manual for time duration
requirements.
Malfunctioning Display
Console.
Test with known good Display Console.
Replace malfunctioning Display Console.
Prompt goes OFF when the
START key is released and
information entry not
allowed.
Malfunctioning Display
Console.
Test with known good Display Console.
Replace malfunctioning Display Console.
Malfunctioning Alternator
Control Board.
Test with known good ACB. Replace defective
Alternator Control Board.
Malfunctioning Alternator. Test Alternator output, or test with known good
Alternator. Replace malfunctioning Alternator.
Display Console keys
(except START key) do not
function.
Attempting to enter program
not available.
Refer to Operation Manual for program
availability.
Display Console connection
loose.
Make sure that the connections at the Display
Console are secure. Remove, then reinstall.
Malfunctioning Display
Console.
Test with substitute Display Console. Replace
malfunctioning Display Console.
Numeric keys disabled. Refer to Diagnostic State 14 to enable numeric
keys.