Lifecycle 9500HR/9100 Series Recumbent Exercise Bikes Customer Support Services SERVICE MANUAL
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes INTRODUCTION HOW TO USE SERVICE MANUAL AND CONTACT CUSTOMER SUPPORT SERVICES This service manual is applicable to Lifecycle Model 9500HR (heart rate function via Lifepulse and Telemetry) and Lifecycle Model 9100 (heart rate function via Telemetry) belt-drive recumbent exercise bikes. Note: Information represents typical configuration and may differ slightly from actual equipment.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes THEORY OF OPERATION The Lifecycle recumbent bikes are stationary exercise bicycles that provide a scientific method of improving body fitness and endurance through its unique “12 or 24 MINUTE RIDE TO VIGOROUS HEALTH.” Computerized state-of-the-art electronics have been engineered to satisfy a range of personalized fitness needs of the beginner to the needs of the most advanced fitness enthusiast.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes TABLE OF CONTENTS SECTION I TROUBLESHOOTING GUIDES PAGE NO POWER ...............................................................................................................................................2 DISPLAY CONSOLE INITIALIZES THEN FAILS ......................................................................................2 ERRATIC DISPLAY CONSOLE LEDs.........................................................................................
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes TABLE OF CONTENTS (continued) SECTION III How To… REPLACE THE… ALTERNATOR ...........................................................................................................................................2 ALTERNATOR BELT ................................................................................................................................3 FREE-WHEEL PULLEY ASSEMBLY ..................................................................
©2001 Brunswick Corporation. All rights reserved. Life Fitness is a registered trademark of Brunswick Corporation. Zone Trainer and Heart Rate Zone Training are trademarks of Brunswick Corporation. Any use of these trademarks, without the express written consent of Brunswick Corporation, is forbidden.
Section I Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes SECTION I TROUBLESHOOTING GUIDES 1
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes TROUBLESHOOTING GUIDE Malfunction No Power. Display Console LEDs do not illuminate. Display Console initializes then fails. 2 Probable Cause Corrective Action Pedaling too slowly. Pedal faster than 45 RPM then press the START button. Insufficient battery voltage. LC95R battery voltage output should be: 5.8 6.3 VDC. LC91R battery voltage output should be: 9.0 VDC.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes TROUBLESHOOTING GUIDE Erratic Display Console LEDs. Display Console LEDs remain illuminated. Probable Cause Corrective Action Pedaling too slowly. Pedal faster than 45 RPM. Insufficient battery voltage. LC95R battery voltage output should be: 5.8 6.3 VDC. LC91R battery voltage output should be: 9.0 VDC. Loose connections at the alternator Power Control Board (PCB) and/or at the Alternator Terminals. Damaged wiring harness.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes TROUBLESHOOTING GUIDE Malfunction Prompt persists and information entry not allowed. Prompt goes OFF when the START key is released and information entry not allowed. Display Console keys (except START key) do not function. 4 Probable Cause Corrective Action Attempting to enter improper duration of time. Refer to Operation Manual for time duration requirements. Malfunctioning Display Console. Test with known good Display Console.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes TROUBLESHOOTING GUIDE Excessive resistance load at start of program. Excessive resistance load during program. Probable Cause Corrective Action Pedaling too slowly. Pedal faster than 45 RPM. Loose connections at the alternator Power Control Board (PCB) and/or at the Alternator Terminals. Damaged wiring harness. Make sure that all connections are secure.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes TROUBLESHOOTING GUIDE Malfunction Resistance varies during manual program. Resistance is constant during random or hill programs. Probable Cause Corrective Action Pedaling too slowly. Pedal faster than 45 RPM. Loose connections at the alternator Power Control Board (PCB) and/or at the Alternator Terminals. Damaged wiring harness. Make sure that all connections are secure.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes TROUBLESHOOTING GUIDE Difficult or no pedaling movement. Pedaling too easy. Probable Cause Corrective Action Malfunctioning Pulley Clutch assembly. Inspect Pulley for free backward and forward rotation. Replace malfunctioning Pulley. Alternator belt excessively tight. Inspect belt deflection. Adjust as necessary. Alternator belt deflection: 1/4 inch (6mm). Left side Crank Nut excessively tight. Loosen nut 1/16 of a turn.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes TROUBLESHOOTING GUIDE Malfunction Battery over-heating. Exercise bike not stable. 8 Probable Cause Corrective Action Reverse polarity. RED wire to positive (+) lead and BLACK wire to negative (-) lead. Battery cable insulation worn and contacting frame. Inspect Wires and replace as necessary. Malfunctioning Display Console. Test with known good Display Console. Replace malfunctioning Display Console.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes TROUBLESHOOTING GUIDE Emitting loud noise. Probable Cause Corrective Action Non-carpeted, hard floor. Place bike on softer surface floor or carpeted area to deaden sound. Leaning excessively to either side. Do not lean. Crank bearings not adjusted properly or worn. Inspect, adjust, and/or replace as necessary. Alternator belt loose. Inspect belt deflection. Adjust the Alternator Belt to 1/4 inch (6mm) deflection. Alternator Belt worn.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes TROUBLESHOOTING GUIDE Malfunction No heart rate or display reads no heart rate (Lifepulse). Probable Cause Corrective Action Heart rate digital signal processor (DSP) board. Verify that the DSP board is communicating. Execute the diagnostic Mode. Faulty cable connection. Verify heart-rate cable is properly connected, then verify for continuity using an ohmmeter. Handlebar/Lifepulse Grip Assembly worn or damaged.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes Section I NOTES: 11
Lifecycle 9500 / 9100 Series Recumbent Exercise Bikes Section II SECTION II DIAGNOSTICS 1
Lifecycle 9500 / 9100 Series Recumbent Exercise Bikes Display Console Layout LC9500 Message Center Profile Window Message Center LC9100 Profile Window 2 Numeric Keypad Arrow Keys
Lifecycle 9500 / 9100 Series Recumbent Exercise Bikes HOW TO ENTER DIAGNOSTIC MODES Section II LC9500 While pedaling the bike over 45 RPMs, diagnostics can be entered by holding the 5 key or the down ARROW key and pressing the START key. LC9100 While pedaling the bike over 45 RPMs, diagnostics can be entered by holding the ‘DOWN ARROW’ key and pressing the ‘START’ key.
Lifecycle 9500 / 9100 Series Recumbent Exercise Bikes DIAGNOSTICS DIAGNOSTICS STATE 1 - ALL LEDS and KEYPAD TEST Diagnostics is entered by holding the ‘DOWN ARROW’ key and depressing the ‘Start’ key while pedaling 45 RPM or faster. On entry to this state, all of the LEDs will turn on. Pressing keys will result in a beep sound and, for all but the START/ENTER’ and ‘CLEAR\PAUSE’ keys, a character repeated across the message center display.
Lifecycle 9500 / 9100 Series Recumbent Exercise Bikes Section II DIAGNOSTICS DIAGNOSTICS STATE 2: INDIVIDUAL LED TEST On entry to this state, the individual LEDs and display segments will be tested. Indicator LEDs, message center segments, and profile LEDs will all animate independently. Press the ‘CLEAR/PAUSE’ key to return to DIAGNOSTICS STATE 1. Press the ‘START/ENTER’ key to advance to DIAGNOSTICS STATE 3.
Lifecycle 9500 / 9100 Series Recumbent Exercise Bikes DIAGNOSTICS P1.31 HR 52 0 DIAGNOSTICS STATE 3 - VERSION#: RPM, HR, and LOAD TESTS The PROGRAM VERSION NUMBER (ex. P1.01) will be displayed in the ELAPSED TIME window. The present RPM will be displayed in the RPM window. The HEART RATE, if present, will be displayed in the LEVEL/HEART RATE window. The present LOAD DUTY CYCLE applied to the alternator will be displayed in the CALORIES/HOUR window if the LIFEPULSE GAIN display has not been selected.
Lifecycle 9500 / 9100 Series Recumbent Exercise Bikes DIAGNOSTICS NONE 0 Section II PX.XX 62 DIAGNOSTICS STATE 3 - VERSION#: RPM, NETWORK STATUS, AND LOAD TESTS (Integrated PCB Only) The PROGRAM VERSION NUMBER (ex. P1.01) will be displayed in the ELAPSED TIME window. The present RPM will be displayed in the LEVEL and HEART RATE windows. The NETWORK STATUS will be displayed in the RPM window. The present LOAD DUTY CYCLE applied to the alternator will be displayed in the CALORIES/HOUR window.
Lifecycle 9500 / 9100 Series Recumbent Exercise Bikes DIAGNOSTICS P 1. 80 P3.90 OFF DIAGNOSTICS STATE 4 - LIFEPULSE and NETWORK STATUS TESTS The PROGRAM VERSION NUMBER of the HEART RATE DSP board ‘05 software (ex. P1.60, if present) will be displayed in the ELAPSED TIME window. The PROGRAM VERSION NUMBER of the HEART RATE DSP board DSP software (ex. P3.80, if present) will be displayed in the HEART RATE window.
Lifecycle 9500 / 9100 Series Recumbent Exercise Bikes DIAGNOSTICS L HR G99 Section II C-0 R DIAGNOSTICS STATE 4 - LIFEPULSE TESTS (Integrated PCB Only) Upon entry to this diagnostic state, the LIFEPULSE software version number is displayed for 2 seconds. After this , the LP Comm Status is displayed for 2 seconds, which will either display 'LP PC COMM ON' or 'LP PC COMM OFF'. Make sure 'LP PC COMM OFF' appears, or CSAFE will not function correctly.
Lifecycle 9500 / 9100 Series Recumbent Exercise Bikes DIAGNOSTICS OFF DIAGNOSTICS STATE 5 - LOOPBACK TEST Within this state, the RS232 port is tested. A shorting jumper must be connected for the result of this test to be correct. If functioning correctly, “RS232 PASS” will be displayed. If not-functioning correctly , “RS232 OFF” will be displayed. Press the ‘CLEAR/PAUSE’ key to return to DIAGNOSTICS STATE 4. Press the ‘START/ENTER’ key to advance to DIAGNOSTICS STATE 6.
Lifecycle 9500 / 9100 Series Recumbent Exercise Bikes DIAGNOSTICS Section II CVA ENABLED DIAGNOSTICS STATE 5 - CVA ENABLE/DISABLE (Integrated PCB Only) Within this state, CVA support can be turned ON or OFF. The "UP" and "DOWN" arrow keys toggle between CVA ENABLED and CVA DISABLED. The ENTER key LED will indicated when the value is at the default setting of CVA DISABLED. This value is stored in EEROM and is kept when the LifeCycle is not in use.
Lifecycle 9500 / 9100 Series Recumbent Exercise Bikes DIAGNOSTICS MAX DURATION 60 DIAGNOSTICS STATE 6 - MAXIMUM PROGRAM DURATION Within this state, the MAXIMUM PROGRAM DURATION is displayed and can be adjusted from a range of 10-99 minutes. The ‘DOWN ARROW’ will decrease the value by 1 minute. The key will Auto-Repeat if held. The ‘UP ARROW’ will increase the value by 1 minute. The key will Auto-Repeat if held. The ENTER key LED indicates when the value is at the default of 60 minutes.
Lifecycle 9500 / 9100 Series Recumbent Exercise Bikes DIAGNOSTICS ON Section II TELEMETRY DIAGNOSTICS STATE 7 - TELEMETRY ENABLE/DISABLE Within this state, the TELEMETRY can be turned ON or OFF. If a telemetry heart rate is detected, it will be displayed when telemetry is set to ON. The Heart Rate LED will also be flashed every time a telemetry pulse is received. By default, the LifeCycles will have TELEMETRY ON. The ‘DOWN ARROW’ will turn off the telemetry.
Lifecycle 9500 / 9100 Series Recumbent Exercise Bikes DIAGNOSTICS ENGLISH UNITS DIAGNOSTICS STATE 8 - ENGLISH/METRIC UNITS Within this state, ENGLISH or METRIC units can be selected. The ‘DOWN ARROW’ will select METRIC units. The ‘UP ARROW’ will select ENGLISH units. The ENTER key LED indicates when the value is at the default setting of ENGLISH UNITS. This value is stored in EEROM and is kept when the unit is not in use. Press the ‘CLEAR/PAUSE’ key to return to DIAGNOSTICS STATE 7.
Lifecycle 9500 / 9100 Series Recumbent Exercise Bikes DIAGNOSTICS Section II RECUMBENT DIAGNOSTICS STATE 9 - MODEL SELECTION Within this state, configuration as an upright or a recumbent LifeCycle can be selected. The ‘DOWN ARROW’ will configure as a Recumbent. The ‘UP ARROW’ will configure as a Upright. The ENTER key LED indicates when the value is at the default setting of UPRIGHT. This value is stored in EEROM and is kept when the unit is not in use.
Lifecycle 9500 / 9100 Series Recumbent Exercise Bikes DIAGNOSTICS WATT PROGRAM ON DIAGNOSTICS STATE 10 - WATTS PROGRAM ENABLE/DISABLE Within this state, WATTS can be turned ON or OFF. By default, the LifeCycle will have the WATTS PROGRAM ON. The ‘DOWN ARROW’ will turn OFF the WATTS PROGRAM. The ‘UP ARROW’ will turn ON the WATTS PROGRAM. The ENTER key LED indicates when the value is at the default setting of WATTS PROGRAM ON. The value is stored in EEROM and is kept when the bike is not in use.
Lifecycle 9500 / 9100 Series Recumbent Exercise Bikes DIAGNOSTICS PROGRAM ON Section II METS DIAGNOSTICS STATE 11 - METS PROGRAM ENABLE/DISABLE Within this state, METS PROGRAM can be turned ON or OFF. By default, the LifeCycle will have the METS PROGRAM ON. The ‘DOWN ARROW’ will turn OFF the WATTS PROGRAM. The ‘UP ARROW’ will turn ON the WATTS PROGRAM. The ENTER key LED indicates when the value is at the default of METS PROGRAM ON. This value is stored in EEROM and is kept when the bike is not in use.
Lifecycle 9500 / 9100 Series Recumbent Exercise Bikes DIAGNOSTICS 6V BATTERY DIAGNOSTICS STATE 12 - POWER SUPPLY CONFIGURATION Within this state, the power supply selection can be made. The arrow keys will scroll through the selections of '6 VOLT BATTERY', 'EXTERNAL SUPPLY', or '9 VOLT BATTERY'. NOTE: LC9100 uses a 9 volt battery. LC9500 uses a 6 volt battery. The ENTER key LED indicates when the value is the default of 6V battery. This value is stored in EEROM and is kept when the unit is not in use.
Lifecycle 9500 / 9100 Series Recumbent Exercise Bikes DIAGNOSTICS 12 Section II HOURS= DIAGNOSTICS STATE 13 - TOTAL HOURS and STATISTICS Upon entry to this state, TOTAL HOURS are displayed. STATISTICS can be displayed using the UP and DOWN arrow keys. The ‘UP ARROW’ allows scrolling through the available programs and shows the number of times each program has been selected. The ‘DOWN ARROW’ backs up through the list of available programs and back to the total hours displayed.
Lifecycle 9500 / 9100 Series Recumbent Exercise Bikes DIAGNOSTICS NUMERIC KEYS ON DIAGNOSTICS STATE 14- NUMERIC KEYS CONFIGURATION Within this state, the unit can be configured as to the presence of numeric keys. The ‘DOWN ARROW’ will display “NUMERICS OFF”. The ‘UP ARROW’ will display “NUMERICS ON”. The ENTER key LED indicates when the value is at the default of NUMERIC KEYS ON. This value is stored in EEROM and is kept when the unit is not in use.
Lifecycle 9500 / 9100 Series Recumbent Exercise Bikes DIAGNOSTICS 135 82 725 Section II 28:45 DIAGNOSTICS STATE 15 PHOTO SHOOT This state is solely intended to be used for PHOTO SHOOTS. None of the data items displayed are real. Press the ‘CLEAR/PAUSE’ key to return to DIAGNOSTICS STATE 14. Press the ‘START/ENTER’ key to advance to DIAGNOSTICS STATE 16.
Lifecycle 9500 / 9100 Series Recumbent Exercise Bikes DIAGNOSTICS DIAGNOSTICS STATE 15 PROGRAMS ENABLE/DISABLE (Integrated PCB Only) Enable or disable HEART RATE HILL, HEART RATE INTERVAL, HEART RATE EXTREME, or REAL WORLD BIKE. The DOWN ARROW will display PROGRAMS OFF. The UP ARROW will display PROGRAMS ON. The ENTER key LED indicates when the value is set to default of PROGRAMS OFF. This value is stored in EEROM and is kept when the unit is not in use.
Lifecycle 9500 / 9100 Series Recumbent Exercise Bikes Section II DIAGNOSTICS DIAGNOSTICS STATE 16 LANGUAGE SELECTION (ntegrated PCB Only) Within this state, the LANGUAGE can be changed to nay one of 7 languages, including English, German, French, Italian, Dutch, Spanish or Portuguese. The UP ARROW will display the next language in the list. The DOWN ARROW will display the previous language in the list. The ENTER key LED indicates when the language is set to the default of ENGLISH.
Lifecycle 9500 / 9100 Series Recumbent Exercise Bikes DIAGNOSTICS DIAGNOSTICS STATE 17 EEPROM TEST (Integrated PCB Only) Within this state, EEPROM can be tested. This diagnostic state tests the Display Console EEPROM by reading, writing, and replacing all used locations in the Display Console EEPROM. The EEPROM location being tested will appear in the display message center. Pressing the DOWN ARROW will initiate the EEPROM test. If the test completes successfully, the message EEPROM GOOD will appear.
Lifecycle 9500 / 9100 Series Recumbent Exercise Bikes DIAGNOSTICS 135 82 725 Section II 28:45 DIAGNOSTICS STATE 18 PHOTO SHOOT (Integrated PCB Only) This state is solely intended to be used for PHOTO SHOOTS. None of the data items displayed are real. Press the ‘CLEAR/PAUSE’ key to return to DIAGNOSTICS STATE 17.
Lifecycle 9500 / 9100 Series Recumbent Exercise Bikes NOTES: 26
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes SECTION III Section III How To...
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes How To...REPLACE THE ALTERNATOR Tools Required: Combination wrenches, belt tension gage, and Phillips screwdriver 1. See “How To…Replace Shrouds” in this section. Alternator Tensioning Bolt 2. Disconnect all terminal wires noting their colors and tagging their locations. 3. Mark the ALTERNATOR position at the TENSIONING BOLT BRACKET, then remove the TENSIONING BOLT. 4. Remove the PIVOT BOLT and hardware from the ALTERNATOR. Red Torque 25-30 IN.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes How To...REPLACE THE ALTERNATOR BELT Tools Required: Combination wrenches, pliers, screwdrivers, e-ring tool, center punch, and belt tensioning gage 1. See “How To…Replace Shrouds” in this section. Idler Bracket 2. Mark the position of the ALTERNATOR TENSIONING BOLT at the MOUNTING BRACKET, then remove TENSIONING BOLT. Tensioning Bolt Torque 5-7 FT. LBS. Mounting Bolt (Loosen) Torque 27-33 IN. LBS. 3.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes How To...REPLACE THE ALTERNATOR BELT (Continued) 6. Remove the RETAINER BOLT and RETAINER from the end of the PULLEY shaft. 7. Remove the left E-RING from the left side of the PULLEY first, then remove the right E-RING. 8. From the belt side, tap out the SHAFT from the unit. 9. Remove the ALTERNATOR BELT. Pulley Shaft Retainer Bolt E-Ring Washer Washer Washer Freewheel Pulley 10. Install the new alternator in the reverse order.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes How To...REPLACE THE FREEWHEEL/PULLEY ASSEMBLY Tools Required: Combination wrenches, pliers, screwdrivers, e-ring tool, center punch, and belt tensioning gage 1. See “How To…Replace Shrouds” in this section. 2. Mark the position of the ALTERNATOR TENSIONING BOLT at the MOUNTING BRACKET, then remove TENSIONING BOLT. Idler Bracket Tensioning Bolt Torque 5-7 FT. LBS. 3.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes How To...REPLACE THE FREEWHEEL/PULLEY ASSEMBLY (Continued) 6. Remove the RETAINER BOLT and RETAINER from the end of the SHAFT. 7. Remove the left E-RING from the left side of the PULLEY first, then remove the right E-RING. 8. From the belt side, tap out the SHAFT from the unit. 9. Pull the FREEWHEEL/PULLEY ASSEMBLY forward and out of the bike. 10. Slide the FREEWHEEL off the SHAFT noting location of washers.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes How To...REPLACE THE POWER GRIP BELT Tools Required: Combination wrenches, pliers, screwdrivers, e-ring tool, center punch, and belt tensioning gage 1. See “How To…Replace Shrouds” in this section. Idler Bracket 2. Mark the position of the ALTERNATOR TENSIONING BOLT at the MOUNTING BRACKET, then remove TENSIONING BOLT. Tensioning Bolt Torque 5-7 FT. LBS. Mounting Bolt (Loosen) Torque 27-33 IN. LBS. 3.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes How To...REPLACE THE POWER GRIP BELT (Continued) 6. Remove the RETAINER BOLT and RETAINER from the end of the SHAFT. 7. Remove the left E-RING from the left side of the PULLEY first, then remove the right E-RING. 8. From the belt side, tap out the SHAFT from the unit. 9. Pull the FREEWHEEL/PULLEY ASSEMBLY forward and out of the bike and remove the POWER GRIP BELT.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes How To...REPLACE THE SEAT LOCKING MECHANISM ASSEMBLY Tools Required: 5/32 inch hex key wrench 1. Disengage the LOCKING MECHANISM and slide the seat to its most forward position. 2. Remove the two 5/32 inch hex key screws from the LOCKING MECHANISM. 4. Install new LOCKING MECHANISM in reverse order. Locking Mechanism Section III 3. Remove the LOCKING MECHANISM.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes How To... REPLACE THE CRANK ARM BEARINGS Tools Required: Special crank arm wrench required (available from Life Fitness), FT LBS. torque wrench, standard screwdriver, hex key set, and clean rag. Bearing Retaining Screw 1. See “How To…Replace Shrouds” in this section. 2. Loosen the POWER GRIP BELT. See “How To…Replace Power Grip Belt.” 3. Remove the left BEARING RETAINER SCREWS (2). 4.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes How To... REPLACE THE CRANK ARM BEARINGS (Cont.) 13. Install the LEFT BEARING NUT assembly over the left CRANKARM, and hand-thread (counterclockwise). Using torque wrench, initially tighten 9-12 FT. LBS. seating torque, then back off the bearing nut and re-torque to 4 FT. LBS. 14. Install a new TAB WASHER on the left crank arm.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes How To... REPLACE THE SEAT ASSEMBLY and EXTRUSION Tools Required: 1/2 inch wrench, Standard screwdriver, and 5/32 inch Hex key wrench 1. See “How To…Replace Shrouds” in this section. 2. Remove the SEAT STOP in front of the seat support by removing two screws from the top and front of the seat assembly. 3.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes How To...REPLACE THE MAIN WIRE HARNESS Tools Required: 1/4, 5/16, and 3/8 inch wrenches, side cutters, and standard screwdriver Main Wire Harness (in handle bar) 1. Refer to “How To…Replace Display Console and Handle Bar” in this section to remove the HANDLEBAR ASSEMBLY and disconnect the MAIN WIRE HARNESS connectors. 2. Refer to “How To…Replace Shrouds” in this section to remove the right SHROUD. 3.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes How To...ADJUST SEAT ROLLER ADJUSTMENT Tools Required: Two torque wrenches, combination wrench set 1. The SEAT ROLLERS are adjusted to a specified resistance load. If the seat moves too freely with excessive side-to-side movement, then the seat rollers must be adjusted as follows. 2. Using a ½ inch wrench, loosen all four(4) SEAT ROLLER CLAMP NUTS, then retighten by hand. 3.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes How To... REPLACE THE BATTERY(LC9500HR) Tools Required: Standard screwdriver 1. Tilt the bike on its side. 2. Disconnect the BLACK (neg) wire from the (-) post on the BATTERY then the RED (pos) wire from the (+) post. 3. Remove the two SCREWS securing the BATTERY to the bracket. Remove the BATTERY and discard. 4. Install new BATTERY and secure with the two SCREWS. Battery Bracket 6V battery 6.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes How To... REPLACE THE BATTERY(LC9100) Tools Required: Phillips screwdriver 1. Locate and remove the SCREW from the BATTERY DOOR located on the rear of the CONSOLE. Console 9 Volt Alkaline Battery 2. Disconnect the 9 VOLT ALKALINE BATTERY from the WIRE HARNESS and replace with a new 9 VOLT ALKALINE BATTERY. 3. Carefully insert 9 VOLT ALKALINE BATTERY and WIRE HARNESS into the back of the display console. 4.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes How To... REPLACE THE CONSOLE AND HANDLEBAR ASSEMBLY Tools Required: Phillips screwdriver and Allen wrench set 1. Remove four PHILLIPS SCREWS from the SUPPORT BRACKET. 2. Lift the DISPLAY CONSOLE off the support bracket to view wiring cables, then disconnect the MAIN CABLE, LIFEPULSE CABLE (LC9500HR), and TELEMETRY CABLE from the back of the DISPLAY CONSOLE. 3. Remove two HEX SCREWS from the front of the HANDLE BAR COLUMN. 4.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes How To... REPLACE THE ALTERNATOR CONTROL BOARD Tools Required: Standard screwdriver 1. Remove the right SHROUD. Refer to See How To...Replace Shrouds” in this section. 2. Note the WIRE HARNESS position and disconnect the ALTERNATOR (P2) and MAIN WIRE HARNESSES (P1) from the ALTERNATOR CONTROL BOARD. Control Board Mounting Screws(4) 3. Remove four mounting SCREWS securing the ALTERNATOR CONTROL BOARD to its mounting bracket. 4.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes How To... REPLACE THE FOOT STRAP Tools Required: None NOTE: THE STRAP HAS BEEN INITIALED “L” FOR LEFT AND “R” FOR RIGHT TO SHOW PEDAL LOCATION. 1. Grasp the outside of the worn STRAP and pull AWAY and DOWN from the knob on the PEDAL. 2. Grasp the inside of the worn STRAP and pull AWAY and DOWN from the knob on the PEDAL. 3. Insert the outside of the new STRAP with the slit on the outside knob of the PEDAL. Pull the STRAP UP until it locks in place.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes How To... REPLACE THE FRONT WHEEL Tools Required: Phillips screwdriver 1. Remove the SCREW and WASHER at the end of the WHEEL. 2. Remove and discard WHEEL. 3. Install new wheel in reverse order. 4. If the wheel inserts require replacement, remove the two INSERT SCREWS and slide INSERT out and replace with new INSERT. Insert Screws Washer Insert Wheel 20 Screw 20-25 IN. LBS.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes How To... REPLACE THE DIGITAL HEART RATE SENSORS (LC9500HR) Tools Required: Phillips screwdriver, standard screwdriver, 5/64” hex key wrench KIT # GK20-00002-0002 NOTE: The kit you have received will come equipped with either 5/64” hex key button head screws or Phillips head pan screws. Either can be used for sensor replacement procedures on all models of Life Fitness exercise equipment equipped with Lifepulse digital heart rate sensors.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes How To... REPLACE THE DIGITAL HEART RATE SENSORS (continued) Installing the new Lifepulse digital heart rate sensors: 4. Plug the Faston connector (red or white wire) to the back of the new, pre-assembled signal output sensor assembly (this will be the assembly without the screw access holes in the sensor) and locate it into position. This sensor will be the sensor on which the palm rests during use. 5.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes How To... REPLACE THE DIGITAL HEART RATE PC BOARD (LC9500HR) Tools Required: Phillips screwdriver, pliers 1. Remove the four SCREWS securing the DISPLAY CONSOLE to the DISPLAY CONSOLE BRACKET. 2. Unplug the 10-PIN CONNECTOR, 4-PIN CONNECTOR, and the 3-PIN CONNECTOR from the back of the DISPLAY CONSOLE. 3. Remove the SCREWS securing the back of the DISPLAY CONSOLE to the OVERLAY FACE-PLATE. Set the OVERLAY face down on a non-abrasive, flat surface.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes How To... REPLACE SIDE SHROUDS Tools Required: 5/8 inch open-end wrench, standard screwdriver, torx wrench set 1. Remove the LEFT PEDAL in a clockwise rotation. 2. Remove the 2 screws securing the ENDCAP and remove. Torque Shroud Screws 6-10 IN. LBS. Right Shroud End Cap 3. Remove 7 screws from the RIGHT SHROUD. Left Shroud 4. Remove the RIGHT SHROUD.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes How To... REPLACE THE PEDALS Tools Required: 5/8 inch open end wrench 1. To remove the LEFT PEDAL, place a 5/8 inch open end wrench on the PEDAL BOLT and turn the wrench clockwise. 3. Install the new PEDALS onto the CRANK ARMS. To tighten the PEDALS, place a 5/8 inch open end wrench on the PEDAL BOLT. Move the wrench counterclockwise for the LEFT PEDAL and clockwise for the RIGHT PEDAL.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes How To... REPLACE THE SEAT BACK Tools Required: 5/32 inch hex key wrench 1. Remove the four SCREWS from the SEAT BACK and remove the seat back. 2. Position the new SEAT BACK against the SEAT FRAME and secure with four mounting SCREWS. NOTE: MAKE SURE THE SEAT IS PROPERLY SECURE BEFORE RIDING.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes How To... REPLACE THE STABILIZER BAR Tools Required: 1/2 inch wrench, short length of 2x4 board or a small box of same size to support bike 1. Raise the rear of the bike and support it with a piece of 2x4 board under the rear of the bike and in front of the STABILIZER BAR. 2. Remove the two STABILIZER BOLTS from the bottom of the STABILIZER BAR. Remove the STABILIZER BAR from the bike frame. 3.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes How To... REPLACE THE TELEMETRY RECEIVER Tools Required: Phillips Screwdriver 1. Remove LABEL from front of cover. 2. Remove the two SCREWS and COVER under the HANDLEBAR. 3. Disconnect TELEMETRY RECEIVER from the wire cable. Removing the receiver from foam insulator. INSTALL NEW TELEMETRY RECEIVER IN REVERSE ORDER. Cable Foam Protector Receiver Unit Cover Screws 6-8 IN. LBS.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes How To... REPLACE THE SEAT PAD and HANDLEBAR ASSEMBLY Tools Required: Allen wrench set, Torx wrench set, and torque wrench 1. Remove the four ALLEN SCREWS and WASHERS securing the SEAT PAD to the SEAT ASSEMBLY. 2. Remove the SEAT PAD from the SEAT ASSEMBLY. 3. Replace the SEAT PAD and secure with ALLEN SCREWS and WASHERS. Torque ALLEN SCREWS to 55-60 IN. LBS. 4.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes How To... REPLACE THE LOCKING RACK Tools Required: Allen wrench set, torque wrench 1. Disengage LOCKING MECHANISM and slide SEAT ASSEMBLY to the rear of the EXTRUSION. 2. Remove ALLEN SCREW from the front of the LOCKING RACK. 3. Disengage LOCKING MECHANISM and carefulley slide SEAT ASSEMBLY to the front of the EXTRUSION. 4. Remove ALLEN SCREW from the rear of the LOCKING RACK and remove LOCKING RACK. 5.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes How To... REPLACE THE ACCESSORY TRAY Tools Required: Phillips screwdriver and 5/32” Hex Key wrench Recumbent Models Kit Required 9500HR AK51-00072-0000 9100, 5500HR, 4500 AK51-00074-0000 1. Using a Hex Key wrench remove the four SCREWS (A) and WASHERS (B) securing the SEAT BACK (C). Remove the SEAT BACK and set it aside. 2. Slide the ACCESSORY TRAY (D) over the user right SEAT BACK POST (E) and down to make contact with the SEAT HANDLEBAR (F).
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes NOTES 32
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes SECTION IV Section IV ELECTRONICS OVERVIEW AND WIRING BLOCK DIAGRAMS 1
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes ELECTRONICS OVERVIEW - LC9100 AND LC9500HR DISPLAY CONSOLE BOARD (Equipped with DSP Heart Rate PCB) Functional Description Connector P5 The Display Console Board is designed to work in conjunction with the Alternator Control Board. It reads the keypad input for changes or updates by the user, and refreshes the status LEDs, data display, and profile display matrix.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes ELECTRONICS OVERVIEW – LC91 AND LC95HR DISPLAY CONSOLE (Equipped with DSP Heart Rate PCB) Location Pin Functional Description P5 is an 8 pin connector that connects the Life Pulse Board to the Console Board. Equipped for LC9500HR only. 1 2 3 4 5 6 7 8 HR-ENABLE (3.8 VDC) KEY VSYS (7-8 VDC) VSYS (7-8 VDC) GROUND GROUND HR-D0 (4.5 VDC) HR-D1 (4.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes ELECTRONICS OVERVIEW - DISPLAY CONSOLE BOARD (Equipped with Integrated PCB) Functional Description P9 and P10 The Display Console Board is designed to work in conjunction with the Alternator Control Board. It reads the keypad input for changes or updates by the user, and refreshes the status LEDs, data display, and profile display matrix.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes ELECTRONICS OVERVIEW - DISPLAY CONSOLE BOARD (Equipped with Integrated PCB) Location Pin 1 2 3 4 Functional Description Right + Right Left Left + P9 and P10 are 8 pin connectors that connect to the CSAFE and Cardio Theater interface 1 2 3 4 5 6 7 8 N/U - not used N/U - not used Receive Data Transmit Data +8 Vdc CTS Ground N/U - not used P7 is a 3 pin connector that connects the polar receiver to the console 1 2 3 +VCC (5VDC) POLAR SIGNAL GROUN
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes ELECTRONICS OVERVIEW - LC9100 ALTERNATOR CONTROL BOARD Functional Description The Alternator Control Board is designed to regulate the alternator voltage by modulating the field current. It regulates the pass current (RPM signal) from the Alternator to the Console, and the pass current from the alternator to the load resistor while providing supply voltage for the console while charging the system battery.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes ELECTRONICS OVERVIEW - LC9500HR ALTERNATOR CONTROL BOARD Functional Description The Alternator Control Board is designed to regulate the alternator voltage by modulating the field current. It regulates the pass current (RPM signal) from the Alternator to the Console, and the pass current from the alternator to the load resistor while providing supply voltage for the console while charging the system battery.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes ELECTRONICS OVERVIEW - ALTERNATOR Functional Description The 12 volt, 35 amp Alternator is designed to provide electrical power to the product, supply load resistance while providing electrical power, and provide the RPM signal from the AC TAP to the Alternator Control Board.
KEYPAD 3 *BLACK UP ENTER START WATTS/METS CLEAR/PAUSE DISPLAY LOCK RACE 13 14 15 16 17 5 6 7 9 10 11 12 P1 1 GND POLAR +VCC *ORANGE *BROWN *BLUE 3 5 6 *BLUE *GREEN *ORANGE 4 9 2 MOLEX MINI-FIT JR. 10 POS. *YELLOW *WHITE 8 7 *BLACK *RED 6 3 *BROW N 9VDC ALKALINE BATTERY 1 P2 **RED **BLACK *GREEN MOLEX MINI-FIT JR. 8 POS.
5 8 0 4 7 RACE DOWN 2 1 UP DSPLY ENTER START N/U CLR/PAUSE WATTS/METS 9 6 3 2 3 *WHITE *BLACK MOLEX MINI-FIT JR. 3 POS. 1 *RED 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 P1 GND POLAR +VCC CON17LIF P7 4 4 *BLACK POLAR RECEIVER 2 2 3 GREEN 3 1 1 RED 10 WHITE CON8S156K2 VBAT VBAT ALTREGLO VSYS GND GND RPM VBAT FLDCMD LOAD 2 3 4 *WHITE *RED *BLACK .100 CENTERLINE 4 POS. 1 *GREEN MOLEX MINI-FIT JR. 4 POS.
5 8 0 4 7 RACE DOWN 2 1 UP DSPLY ENTER START N/U CLR/PAUSE WATTS/METS 9 6 3 2 3 *BLACK MOLEX MINI-FIT JR. 3 POS.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes NOTES: 12
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes SECTION V Section V PARTS IDENTIFICATION 1
Lifecycle 9100 Series Recumbent Exercise Bikes LC91R-0100-26 SN 476098-Up Display Console SK51-00073-0001(R) Eng/Met AK51-00073-0003 Ger/Met AK51-00073-0004 Spn/Met AK51-00073-0007 Frn/Met AK51-00073-0008 Itl/Met AK51-00073-0009 Dut/Met Battery Cover(Black) OK36-01035-0006 Overlay Bezel SK51-00035-0001Eng/Met AK51-00035-0003 Ger/Met AK51-00035-0004 Spn/Met AK51-00035-0007 Frn/Met AK51-00035-0008 Itl/Met AK51-00035-0009 Dut/Met Polar HR Kit SK40-00045-0001 Console Case(Black) OK36-01034-0006 Grips OK
Lifecycle 9100 Series Recumbent Exercise Bikes LC91R-0100-26 SN 4763098-Up Bearing w/ Cranknut (LT) AK18-00029-0001 Crankarm OK18-01281-0000 Crankarm Bearing(RT) w/Cranknut AK18-00116-0001 Crank Bearing Set GK51-00002-0001 Tabbed Lockwasher OK18-01280-0001 Left Cranknut OK18-01059-0002 Bearing Retainer Screw 0017-00101-1615 Idler Arm Bracket OK51-01022-0000 Extruded Tube Assembly SK51-00036-0000 Console Wire harness AK51-00060-0000 Grip OK14-01124-0000 Crank Arm w/Pulley SK51-00024-0000 Locking Rac
Lifecycle 9100 Series Recumbent Exercise Bikes LC91R-0100-26 SN 476098-Up End Cap OK19-01208-0000 Seat Assembly w/o Back SK51-00027-0000 Locking Mechanism SK51-00053-0000 Front Stop Bracket OK51-01062-0000 Plastic Shield OK19-01185-0000 Roller Guard OK51-01059-0000 Shroud Bracket OK51-01027-0000 Shroud w/ Decal(RT) SK51-00059-0001 Shroud Decal(RT) OK51-01051-0000 Shroud Screw(11) 0017-00101-0991 4 Wheel Assembly SK51-00054-0000 Wheel Bearing Assembly SK18-00016-0000 Wheel Inserts OK51-01017-0000 Wh
Lifecycle 9100 Series Recumbent Exercise Bikes LC91R-0100-29 Overlay Bezel AK49-00033-0001Eng/Met Battery Cover(Black) OK36-01035-0006 Display Console AK51-00081-0001 AK49-00033-0003 Ger/Met AK49-00033-0004 Spn/Eur AK49-00033-0005 Spn/Met AK49-00033-0007 Frn/Met AK49-00033-0008 Itl/Met AK49-00033-0009 Dut/Met AK49-00033-0010 Frn/Met Polar HR Kit SK40-00045-0001 Console Case(Black) OK36-01034-0006 Grips OK14-01124-0000 Pedal w/Strap(L) AK17-00026-0015 Seat Back Assembly OK51-01056-0000 Console Post
Lifecycle 9100 Series Recumbent Exercise Bikes LC91R-0100-29 Bearing Kit GK51-00002-0001 Bearing w/Cranknut (LT) AK18-00029-0001 Crankarm OK18-01281-0000 Crankarm Bearing(RT) w/Cranknut AK18-00116-0001 Crank Bearing Set GK51-00002-0001 Tabbed Lockwasher OK18-01280-0001 Left Cranknut OK18-01059-0002 Bearing Retainer Screw 0017-00101-1615 Idler Arm Bracket OK51-01022-0000 Extruded Tube Assembly SK51-00014-0000 Console Wire harness AK51-00013-0000 Heart Rate Electrode Kit GK20-00002-0002 Crank Arm w/Pul
Lifecycle 9100 Series Recumbent Exercise Bikes LC91R-0100-29 End Cap 0K19-01208-0000 Seat Assembly w/o Back SK51-00011-0000 Locking Mechanism SK51-00053-0000 Front Stop Bracket 0K51-01062-0000 Plastic Shield 0K19-01185-0000 Roller Guard 0K51-01059-0000 Shroud Bracket 0K51-01027-0000 Shroud w/ Decal(RT) AK51-00085-0001 Shroud Screw(11) 0017-00101-0991 Wheel Assembly SK51-00054-0000 Wheel Bearing Assembly SK18-00016-0000 Wheel Inserts 0K51-01017-0000 Wheel Washers 0K17-01029-0000 Wheel Screw 0017-0010
Lifecycle 9500HR Series Recumbent Exercise Bikes LC95R-0100-26 SN 638144-Up Display Console SK51-00010-0001(R) Eng/Met SK51-00010-0003 Ger/Met AK51-00010-0004 Spn/Eur AK51-00010-0005 Spn/Met AK51-00010-0006 Jap/Met AK51-00010-0007 Frn/Eur AK51-00010-0008 Itl/Met AK51-00010-0009 Dut/Met AK51-00010-0010 Frn/Met Battery Cover(Black) OK36-01035-0006 Grips OK14-01124-0000 Pedal w/Strap(L) AK17-00026-0015 Seat Back Assembly OK51-01055-0000 AK51-00069-0003 Ger/Met AK51-00069-0004 Spn/Eur AK51-00069-0005 Spn
Lifecycle 9500HR Series Recumbent Exercise Bikes LC95R-0100-26 SN 638144-Up Bearing Kit GK51-00002-0001 Bearing w/ Cranknut (LT) AK18-00029-0001 Crankarm OK18-01281-0000 Crankarm Bearing(RT) w/Cranknut AK18-00116-0001 Crank Bearing Kit GK51-00002-0001 Tabbed Lockwasher OK18-01280-0000 Left Cranknut OK18-01059-0002 Bearing Retainer Screw 0017-00101-1615 Idler Arm Bracket OK51-01022-0000 Heart Rate Electrode Kit GK20-00002-0002 Handle Bar w/Inser SK19-00108-0000 Crank Arm w/Pulley AK51-00024-0000 Loc
Lifecycle 9500HR Series Recumbent Exercise Bikes LC95R-0100-26 SN 638144-Up End Cap OK19-01208-0000 Seat Assembly w/o Back SK51-00011-0000 HR Wire Harness AK19-00081-0001 Locking Mechanism SK51-00053-0000 Front Stop Bracket OK51-01062-0000 Plastic Shield OK19-01185-0000 Roller Guard OK51-01059-0000 Shroud Bracket OK51-01027-0000 Shroud w/ Decal(RT) SK51-00015-0001 Shroud Decal(RT) OK51-01041-0000 Shroud Screw(11) 0017-00101-0991 10 Wheel Assembly SK51-00054-0000 Wheel Bearing Assembly SK18-00016-
Lifecycle 9500HR Series Recumbent Exercise Bikes LC95R-0100-29 Display Console AK51-00087-0001(R) Eng/Met AK51-00087-0003 Ger/Met AK51-00087-0004 Spn/Eur AK51-00087-0005 Spn/Met AK51-00087-0006 Jap/Met AK51-00087-0007 Frn/Eur AK51-00087-0008 Itl/Met AK51-00087-0009 Dut/Met AK51-00087-0010 Frn/Met Battery Cover(Black) OK36-01035-0006 Polar HR Kit SK40-00045-0001 Console Case(Black) OK36-01187-0008 AK51-00069-0003 Ger/Met AK51-00069-0004 Spn/Eur AK51-00069-0005 Spn/Met AK51-00069-0007 Frn/Eur AK51-00069
Lifecycle 9500HR Series Recumbent Exercise Bikes LC95R-0100-29 Bearing Kit GK51-00002-0001 Bearing w/ Cranknut (LT) AK18-00029-0001 Crankarm OK18-01281-0000 Crankarm Bearing(RT) w/Cranknut AK18-00116-0001 Crank Bearing Kit GK51-00002-0001 Tabbed Lockwasher OK18-01280-0000 Left Cranknut OK18-01059-0002 Bearing Retainer Screw 0017-00101-1615 Idler Arm Bracket OK51-01022-0000 Heart Rate Electrode Kit GK20-00002-0002 Extruded Tube Assembly SK51-00014-0000 Console Wire harness AK51-00013-0000 Handle Bar
Lifecycle 9500HR Series Recumbent Exercise Bikes LC95R-0100-29 End Cap OK19-01208-0000 Seat Assembly w/o Back SK51-00011-0000 HR Wire Harness AK19-00081-0001 Locking Mechanism SK51-00053-0000 Front Stop Bracket OK51-01062-0000 Plastic Shield OK19-01185-0000 Roller Guard OK51-01059-0000 Shroud Bracket OK51-01027-0000 Shroud w/ Decal(RT) SK51-00015-0001 Shroud Screw(11) 0017-00101-0991 Wheel Assembly SK51-00054-0000 Wheel Bearing Assembly SK18-00016-0000 Wheel Inserts OK51-01017-0000 Wheel Washers OK
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes NOTES: 14
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes SECTION VI Section VI MISCELLANEOUS INFORMATION 1
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes MODEL IDENTIFICATION and SERIAL NUMBER LOCATION Serial Number Location 2
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes PREVENTIVE MAINTENANCE TIPS Preventive Maintenance Schedule DAILY MONTHLY BI-ANNUALLY HOUSING Clean Clean ALTERNATOR CONTROL Heatsink Connectors Board Belt (Power Grip) Crank Bearings Pedals Freewheel Pulley Alternator Flywheel Locking Mechanism Top Surface Rollers Tension Wear Lifepulse sensors Clean Inspect Inspect Inspect Inspect Clean/Inspect Clean/Inspect Clean/Inspect Inspect SEAT ASSEMBLY Clean Inspect ALTERNATOR BELT Inspect Inspect Clea
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes Unpacking Instructions IMPORTANT SAVE YOUR PACKING MATERIALS IN CASE OF RETURN Seat Back Handlebar Assembly Accessory Tray (model R9i only) Display Console Operation Manual Installation Instructions Parts Bag Note: Console assembly is not included with media platform bike.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes COMMUNICATING BY FAX Section VI If you would like to submit a parts order, or if you need help troubleshooting a problem, we have included, for your convenience, a FAX form on the following page. Simply make a copy (or copies) of the FAX sheet and fill in the necessary information. You may FAX us at any time, 24 hours a day, to either of the numbers shown.
CUSTOMER SUPPORT SERVICES PARTS ORDER SALE ( IF BOTH PLEASE INDICATE ) PRODUCT TROUBLESHOOTING WARRANTY NAME: CUSTOMER NO: DATE: PHONE: FAX: CONTACT NAME: METHOD OF SHIPMENT: 1 DAY 2 DAY GROUND PARTS ORDER FORM ITEM NO. 1 PART NUMBER DESCRIPTION QUANTITY 2 3 4 5 6 PRODUCT TROUBLESHOOTING PRODUCT NAME: SERIAL NO. DETAILED DESCRIPTION OF PROBLEM: PRODUCT NAME: SERIAL NO.
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes Section VI NOTES: 7