User Manual
4.3.3 Changing the bearing parts
Fig. 7
u
Using the accompanying Allen key, unscrew the threaded
pin
Fig. 7 (40)
by about 1 turn.
u
Turn and lift out the bearing pin
Fig. 7 (22)
together with
washer
Fig. 7 (23)
and adjustable-height foot
Fig. 7 (24)
.
u
Lift off the stopper
Fig. 7 (21)
.
u
Unscrew the turn hinge
Fig. 7 (25)
.
u
Fully unscrew the threaded pin
Fig. 7 (40)
and screw it in on
the opposite side, at the turn hinge, until it is flush outside
with the turn hinge.
u
Unscrew the bearing element
Fig. 7 (28)
, turn it through
180° and screw it firmly back into place .
u
Re-insert the stopper
Fig. 7 (21)
into the other hole.
u
Carefully lift off the cover on the handle side
Fig. 7 (27)
and
transfer it to the opposite side.
u
Screw the turn hinge
Fig. 7 (25)
firmly into place on the new
hinge side, possibly using a cordless screwdriver (with
4 Nm).
u
Re-insert the bearing pin
Fig. 7 (22)
together with washer
and adjustable-height foot.
u
Tighten the threaded pin
Fig. 7 (40)
.
4.3.4 Transferring the handle
Fig. 8
u
Lift the stopper
Fig. 8 (30)
out of the door bearing bush and
transfer it.
u
Dismantle the door handle
Fig. 8 (31)
, stoppers
Fig. 8 (32)
and pressure plates*
Fig. 8 (33)
and transfer to the opposite
side.
u
When fitting the pressure plates on the opposite side, make
sure they snap properly into place.*
4.3.5 Fitting the door
u
Place the door from above onto the lower bearing pin
Fig. 7 (22)
.
u
Close the door.
u
Insert the upper turn hinge
Fig. 6 (12)
in the door on the new
hinge side.
u
Screw the upper turn hinge
Fig. 6 (12)
firmly into place (with
4 Nm)(2x Torx® 25)
Fig. 6 (13)
. Possibly make preliminary
holes with a bradawl or use a cordless screwdriver.
u
Snap the cover
Fig. 6 (10)
and cover
Fig. 6 (11)
into place at
the opposite side.
4.3.6 Fitting the soft stop unit
Fig. 9
u
Remove the cover
Fig. 9 (7)
from the faceplate
Fig. 9 (1)
and
re-insert it at the other side.
u
Engage the soft stop unit with the joint pointing to the hinge
side (A) and swivel into place (B).
w
The screw holes at the left and right have to register.
u
Screw down the soft stop unit (2x Torx® 15)
Fig. 9 (6)
.
Fig. 10
u
Attach the faceplate
Fig. 10 (1)
to the soft stop bracket so
that the catches face forwards and the front faces the appli-
ance.
u
Draw the soft stop bracket
Fig. 10 (5)
towards the bearing
part
Fig. 10 (26)
and re-insert the pin
Fig. 10 (4)
from above
so that the square sits in the recess.
u
Attach and engage the cover
Fig. 10 (2)
.
w
Pay attention that the cover fits properly so that the door
closes properly and the pin is secured.
u
Twist the safety lock
Fig. 10 (3)
for removal.
u
Snap the faceplate
Fig. 10 (1)
onto the door.
u
Close the door.
4.3.7 Aligning the door
u
Align the door to the appliance housing by way of the two
oblong holes in the bottom turn hinge
Fig. 7 (25)
. To do so,
unscrew the middle screw.
Putting into operation
* Depending on model and options 7