Specification Sheet

home.liebherr.com/monolith
Subject to modifi cation. For up-to-date information, visit home.liebherr.com/monolith.
Specifi cations are for planning purposes only. For more detailed information refer to installation instructions or Design Guide.
IMPORTANT!
Stated minimum height dimensions include
when the leveled feet are fully inserted.
Height can be increased by a maximum of
.teef elba tsujda eht gninrut yb )mm 62( "1
When the appliance is fitted in the recess,
the appliance must be raised by turning the
adjustable feet so that the appliance top
has contact with the anti-tipping bracket.
This results in a 4" (102 mm) Toe Kick height.
Product Dimensions
Inset
A = 15 3/4" (400 mm)
B = 1/2" (12.5 mm)
C = 37 7/8" (962 mm)
Frameless
A = 16" (406 mm)
B = 1/2" (12.5 mm)
C = 38 3/8" (975 mm)
Dimension A = without
mounted door handle
36" recess
Inset installation style
H = 79 7/8" (2029 mm)
W = 35 3/4" (908 mm)
Frameless installation style
H = 80" (2032 mm) Add overlapping
dimension to the panel on the top.
W = 36" (914 mm) Add overlapping
dimension to the panel on both sides.
Panel thickness: Min. 5/8" (16 mm)* / Max. 1" (25.4 mm)
Panel and handle weight: Max. 88 lbs. (40 kg)
Individual Toe Kick
Cut out Dimensions
Door Panel Dimensions
and dimensions of free length for power
Continuous Toe Kick
84"
(2134 mm)
4"
(102 mm)
36"
(914 mm)
A
B
13 3
2
/16" - 4
/16"
(72 - 106 mm)
3"
(76 mm)
3"
(76 mm)
DD
C
E1
E1
84"
(2134 mm)
36"
(914 mm)
A
B
3"
(76 mm)
3"
(76 mm)
DD
C
W
H
~
8.8 ft (2400 mm)
~
5 ft (1550 mm)
* If a shaker style panel is used, which is thinner than the minum panel thickness, shorter screws than those supplied in the accessory pack must be used.
C
A
Cabinet depth frameless installation style = 25" (635 mm)
Cabinet depth inset installation style = 25" (635 mm) +
panel thickness
B
This is the point where the power cord exits from the
appliance rear. 3/4" (19 mm) from the left and 5"
(127 mm) from the floor. Free length of the power cord
is 98" (2.5 m). We recommend power outlet to be placed
outside of the appliance opening.
A 15 or 20 A,
110 -120 VAC circuit grounded and protected by a circuit
breaker or fuse is required.
C
The appliance has a recess in this area for cable and
waterline laying. 1" (25 mm) in depth and 5 1/2"
(140 mm) in height
The water pressure must be in the range of 40 - 90 psi.
over the whole width of the appliance.
A shut-off valve must be installed between the water line and
the main water supply. It must be easily accessible so the
water supply can be stopped immediately if necessary.
D
This surface is visible when the appliance door is open.
Designed finish is required.
E1, E2
Depending on the appliance, the anti-tipping bracket is
positioned at the top (E1) or base (E2) of the appliance
and must be secured to the wall or to the floor, please
refer to the installation manual for more information.
E2
E2
36"