Verify the following:
• Floors can support appliance’s weight plus approximately 
1200 pounds (544 kg) of food weight. 
• Finished kitchen floor height is level. Refrigerator must be 
shimmed to the floor level or leveled to make sure air vents 
are not obstructed.
• Remove anything attached to the rear or side walls that 
can obstruct appliance opening.
• Cut out dimensions are accurate.
• Electrical outlet is in correct location.
Do not install this unit next to any other refrigerator or freezer 
except another Liebherr model. Liebherr models are designed to  
allow for Side-by-Side installation. They are equipped with a  
heating system to eliminate condensation when units are installed 
Side-by-Side. Installing this unit next to any other refrigerator  
or freezer can cause condensation or cause damage to the  
Liebherr unit.
IMPORTANT
To protect the refrigerator from possible damage, allow the 
appliance to stand 1 hour in place before turning the electricity 
on. This allows the refrigerant and lubrication system to reach 
equilibrium.
Blocking For Safety
The anti-tipping bracket must be installed to prevent the unit
from tipping after it is installed. Refer to chapter “Blocking
For Safety” in the installation instructions.
Safety Regulations 
The appliances are designed to cool, freeze, store food as well 
as make ice (if equipped). 
The appliances are manufactured to operate within specific 
ambient temperature limits according to its climate rating. 
The climate rating indicates the ambient temperature at which 
the appliance may be operated in order to deliver optimal 
refrigeration performance. 
The climate rating for Monolith columns is SN-T.
IMPORTANT
Do not operate the appliance outside the specified ambient 
temperature range.
•  Refrigerant circuits are tested for leaks.
•  The appliances complies with current safety regulations
CAN/CSA C22.2 No.60335-1-11
UL 60335-1 Fifth Edition
CAN/CSA C22.2 No. 60335-2-24-06
UL 60335-2-24 First Edition
 Climate Rating  Ambient Temperature
SN 50 °F to 90 °F (10 °C to 32 °C)
N 61 °F to 90 °F (16 °C to 32 °C)
ST 61 °F to 100 °F (16 °C to 38 °C)
T 61 °F to 109 °F (16 °C to 43 °C)
SN-ST 50 °F to 100 °F (10 °C to 38 °C)
SN-T  50 °F to 109 °F (10 °C to 43 °C)
Electrical Requirements & Safety 
A 15 amp or 20 amp, 110-120 VAC, circuit which is grounded 
and protected by a circuit breaker or fuse is required.
We recommend using a dedicated circuit for each appliance 
to prevent circuit overload and the chance of interruption to the 
appliance.
The appliances are equipped with a three-prong (grounding) 
polarized plug for protection against possible shock hazards.
Comply with the National Electrical Code as well as local codes 
and ordinances when installing the receptacle.
 WARNING!
Electrocution hazard.
Electrical grounding required.
• Do not remove the round grounding 
prong from the plug. 
• Do not use extension cords or ungrounded 
(two-prong)   adapters. 
• Do not use a power cord that is frayed or 
damaged. 
• Do not use a power strip.
Failure to follow these instructions may 
result in fire, electrical shock or death.
 WARNING!
The refrigerant R600a contained within the appliances is 
environmentally friendly, but flammable. Leaking refrigerant 
can ignite.
To prevent possible ignition, designed ventilation is required.
Internal Water Dispenser and IceMaker 
(if equipped)
Monolith appliances that are equipped with an internal water 
dispenser or an IceMaker must be connected to a water supply.
The water supply pressure requirements are different based 
on whether or not the supplied Liebherr water filter is installed. 
With the filter installed, the pressure must be in the range  
of 40–90 psi (2.8–6.2 bar). Without the filter installed the  
acceptable pressure range is 22–87 psi (1.5–6 bar).
Use a braided style IceMaker hose with 1/4" compression
end or a 1/4" OD copper line to connect the water supply
with the solenoid valve of the appliance. This is not supplied
with the appliance.
If you have hard water, we recommend you install a water 
 softener. Also, a filter must be installed if the water contains solids 
such as sand. 
All equipment and devices used to supply the water to the  
appliance must comply with the current regulations for your  
geographical area.
All models equipped with an internal water dispenser or IceMaker 
include a water filter located in the front base of the product. 
Water filters must be replaced periodically. An alarm in the  
InfinitySwipe will indicate when the water filter must be replaced.
Safety Instructions and Warnings
• Do not attach the water source while the appliance is connect-
ed to an electrical outlet.
• A shut-off valve must be installed between the hose line and  
the main water supply so that the water supply can be  
stopped if necessary. Do not install the shut-off valve behind  
the appliance.
• The connection to the water supply may only be made by a 
trained and licensed plumber.
• The water quality must comply with the drinking water  
regulations for the geographical area where the appliance  
is located.
• The IceMaker is designed exclusively to make ice cubes in 
quantities needed by a household, and may only be operated 
with water appropriate for this purpose.
• All repairs and work on the IceMaker may only be done by 
Customer Service personnel or other trained personnel.
• The manufacturer cannot accept liability for damage caused  
by equipment or water lines between the solenoid valve and  
the water supply.