Design Guide

20
Fully Integrated
Cabinet Opening Dimensions HC/HCB 2060, HC/HCB 2061, HC 2062, HCB 2062
IMPORTANT
With 24" cabinets, the water line outlet must be in the
location as shown.
With cabinets deeper than 24" there is room to fit the
pipe behind the appliance and the wall so there are no
requirements for the water line lead out position.
The free length of the water supply line must be at least
31 - 1/2" (800 mm) when the tube comes out of the
prescribed opening.
Do not install the shut-off valve for the
water line behind the appliance.
Water line outlet
Water supply line
Inset cabinet Depth D Frameless cabinet Depth D
24" + panel thickness 24"
Concerning the refrigerator compartment there is the op-
tion to choose between stainless steel panels for a 80”
or a 84” installation situation.
When using your own custom overlay panels, only the
80" opening minimum would apply. Opening height can
be taller than the 80" minimum by any amount but be
sure to adjust panel height accordingly.
IMPORTANT
Factory available stainless steel panels are designed for
an inset installation only and require a cabinet / gable
depth of 24 - 3/4".
36" Single
72" Side by Side
Use a braided style ice maker hose with 1/4" compression
end or a 1/4" OD copper line to connect the water supply
with the solenoid valve of the appliance.
This is not supplied with the appliance.
The supplied brass fitting must be used
to connect to the solenoid as the plastic
threads on the solenoid are metric.