Use and Care Manual

Table Of Contents
Fig. 9
u
Close upper door.
u
Pull cover
Fig. 9 (10)
forward and upwards to remove.
u
Lift off cover
Fig. 9 (11)
.
CAUTION
Risk of injury if the door tips out!
u
Keep a steady grip on the door.
u
Set the door down carefully.
u
Unscrew upper bearing bracket
Fig. 9 (12)
(2 x Torx®
25)
Fig. 9 (13)
and pull it upwards to remove.
u
Lift the upper door up and off and set it to the side.
4.3.3 Remove lower soft stop damper
Fig. 10
u
Open the lower door.
NOTICE
Risk of damage!
If the door seal is damaged the door may not close prop-
erly and the level of cooling is insufficient.
u
Do not damage the door seal with the screwdriver!
u
Release panel
Fig. 10 (20)
using a slotted screwdriver
and remove.
w
The panel hangs above the damper bracket
Fig. 11
u
Push panel forward over the damper bracket
Fig. 11 (24)
in the direction of the appliance.
u
Engage locking device
Fig. 11 (22)
into place inside
oblong hole.
w
The locking device prevents the hinge from snapping
shut
u
Lift off cover
Fig. 11 (21)
from the outside using a screw-
driver and remove by pulling outwards.
u
Tip the appliance rearwards with the help of a second
person if needed.
u
Push bolt
Fig. 11 (23)
out from below.
u
Press damper bracket
Fig. 11 (24)
in the direction of the
door.
u
Remove panel
Fig. 11 (20)
.
u
Unscrew entire soft stop unit (2 x Torx® 15)
Fig. 11 (25)
.
u
Slightly pull out soft stop unit, push it towards the
handle side and open it out
u
Set soft stop unit to the side
4.3.4 Removing the lower door
u
Close the lower door.
u
Pull center bearing pin
Fig. 12 (32)
and disc
Fig. 12 (34)
out of the bearing bracket and the lower door.
u
Remove plastic cap
Fig. 12 (33)
.
CAUTION
Risk of injury if the door tips out!
u
Keep a steady grip on the door.
u
Set the door down carefully.
u
Open the lower door.
u
Unscrew center bearing bracket
Fig. 12 (31)
(2 x Torx®
25).
u
Lift lower door upwards to remove and set it to the side
Start-up
8 * Depending on model and options