The cross section of the ventilation gap below the
ceiling must be at least 46.5 in
2
(300 cm
2
).
-
The bigger the ventilation gap, the more energy-saving
the operation of the appliance.
If the appliance is installed with the hinges next to a wall
Fig. 33 (4)
, the gap between the appliance and the wall
must be at least 1-9/16 '' (40 mm). This is how far the
handle protrudes when the door is open.
4.7 Anti-tip device
The screws for fastening the anti-tip device are not
supplied with the appliance. Appropriate screws must be
used for the material (wood, concrete, etc.) in which the
safety device is mounted.
WARNING
Risk of injury if the appliance tips over!
u
Install the anti-tip device to prevent the appliance from
tipping over when the fully loaded door is open.
NOTICE
Risk of damage due to leaking water!
If the tilt safety device has been fitted in another position
than the one given, the water hoses may be damage
when pushing the appliance into the niche.
u
Only fit the tilt safety device in the position shown in the
diagram.
Fig. 34
u
Mark the installation position for the anti-tip device on
the wall or back of the unit.
u
Install the anti-tip device
Fig. 34 (1)
using appropriate
screws
Fig. 34 (2)
.
4.8 Installing the water filter*
The water filter ensures optimum water
quality and is available as an accessory. It
should be installed near the appliance in
the cabinet, for example in the adapter
cabinet above the appliance. To connect
the filter to the appliance, it may be neces-
sary to make an opening (C) in the floor of
the adapter cabinet through which the
hoses will be routed. Depending on your
installation setup, you can route the two
water filter hoses either through the rear
panel or through the base of the cabinet.
The maximum length of the water hose
is118-1/8 '' (3 m).
Alternatively, the appliance can also be
operated without the water filter.
Fig. 35
(A) 13/16 in (20mm) (C) 1-3/16in. x 3/8in.
( 30mm x 10mm )
(B) 3-15/16 in (100mm) (D) min. 4 in (100mm)
The filter cover must be installed during assembly, so
leave sufficient space around the filter module. Maintain
the dimensions shown in
Fig. 35
so that the filter can be
replaced and the cover can be removed.
Flow rate 0.5 gpm (1.89 lpm)
Water connection Drinking water
Water pressure 40 psi - 90 psi ( 2.8 bar - 6.2 bar/ 0.28 MPa
- 0.62 MPa )
Water temperature 33 °F - 100 °F ( 0.6 °C - 37 °C )
Capacity 300 gal. (1.14 l)
WARNING
Consuming contaminants can be harmful to your health!
u
If there is a chance the water may contain harmful
bacteria or if the water quality is unknown, do not use
this system without appropriate disinfection measures
upstream or downstream of the system.
Start-up