WARNING
Poisoning Hazard!
u
The water quality must comply with the drinking water
regulations for the geographical area where the appli-
ance is located.
u
Connect to potable water supply only.
u
The IceMaker is designed exclusively to make ice
cubes in quantities needed by a household and must
only be operated with water appropriate for this
purpose.
Water pressure:
psi MPa (bars)
21.76 to 87.02 0.15 to 0.6 (1.5 to 6)
If a water filter is used, the instructions on water pressure
in the Installing the water filter section apply.
- Water must be supplied to the appliance through a cold
water pipe that complies with hygiene standards and
can withstand the operating pressure.
- All devices and equipment used to supply water must
comply with the regulations in force in the respective
country.
- The solenoid valve is located at the bottom of the back
of the appliance. It has a metric R3/4 connecting
thread.
Fig. 32
u
Remove the cap
Fig. 32 (1)
from the solenoid valve
Fig. 32 (2)
.
u
Ensure that the gasket
Fig. 32 (3)
is inserted in the
elbow connection
Fig. 32 (4)
supplied.
u
Connect the elbow adapter
Fig. 32 (4)
to the solenoid
valve
Fig. 32 (2)
and tighten with an open-ended
wrench, for example.
NOTICE
Risk of thread damage!
u
Do not overtighten.
u
Connect the domestic water supply
Fig. 32 (5)
(e.g.
copper pipe) to the elbow connector
Fig. 32 (4)
.
Before fitting into the cabinet:
u
Check the whole water system for leaks.
Before using for the first time:
u
Have the water line bled (remove air) by a competent
professional.
NOTICE
Malfunction of the water intake!
If the water intake is shut off during operation but the
IceMaker remains in operation, the water intake pipe may
ice up.
u
Switch off the IceMaker if the water supply is inter-
rupted (e.g. holiday).
4.6 Installation into a fitted kitchen
Fig. 33
(1) Top cupboard (3) Kitchen cabinet
(2) Appliance (4) Wall
The appliance can be built into the range of kitchen units.
To bring the appliance
Fig. 33 (2)
up to the height of the
fitted kitchen units, a suitable top cupboard
Fig. 33 (1)
can
be added above the appliance.
When installing with kitchen cabinets (max.
depth. 22-27/32 '' (580 mm)) the appliance can be
installed right next to the kitchen cabinet
Fig. 33 (3)
. The
appliance door projects 1-11/32 '' (34 mm) at the side and
in the center of the appliance 1-31/32 '' (50 mm) from the
front of the kitchen cabinet. This allows it to open and
close properly.
Ventilation requirements:
-
There must be a ventilation shaft at least 1-31/32 ''
(50 mm) deep at the back of the top cupboard over the
entire width of the top cupboard.
Start-up