Have the water line bled (remove air) by a competent
professional.
NOTICE
Malfunction of the water intake!
If the water intake is shut off during operation but the
IceMaker remains in operation, the water intake pipe may
ice up.
u
Switch off the IceMaker if the water supply is inter-
rupted (e.g. holiday).
4.6 Installation into a fitted kitchen
Fig. 32
(1) Top cupboard (3) Kitchen cabinet
(2) Appliance (4) Wall
The appliance can be built into the range of kitchen units.
To bring the appliance
Fig. 32 (2)
up to the height of the
fitted kitchen units, a suitable top cupboard
Fig. 32 (1)
can
be added above the appliance.
When installing with kitchen cabinets (max.
depth. 22-27/32 '' (580 mm)) the appliance can be
installed right next to the kitchen cabinet
Fig. 32 (3)
. The
appliance door projects 1-11/32 '' (34 mm) at the side and
in the center of the appliance 1-31/32 '' (50 mm) from the
front of the kitchen cabinet. This allows it to open and
close properly.
Important for ventilation:
-
There must be a ventilation shaft at least 1-31/32 ''
(50 mm) deep at the back of the top cupboard over the
entire width of the top cupboard.
-
The cross section of the ventilation gap below the
ceiling must be at least 46.5 in
2
(300 cm
2
).
-
The bigger the ventilation gap, the more energy-saving
the operation of the appliance.
If the appliance is installed with the hinges next to a wall
Fig. 32 (4)
, the gap between the appliance and the wall
must be at least 1-9/16 '' (40 mm). This is how far the
handle protrudes when the door is open.
4.7 Anti-tip device
The screws for fastening the anti-tip device are not
supplied with the appliance. Appropriate screws must be
used for the material (wood, concrete, etc.) in which the
safety device is mounted.
WARNING
Risk of injury if the appliance tips over!
u
Install the anti-tip device to prevent the appliance from
tipping over when the fully loaded door is open.
NOTICE
Risk of damage due to leaking water!
If the tilt safety device has been fitted in another position
than the one given, the water hoses may be damage
when pushing the appliance into the niche.
u
Only fit the tilt safety device in the position shown in the
diagram.
Fig. 33
u
Mark the installation position for the anti-tip device on
the wall or back of the unit.
u
Install the anti-tip device
Fig. 33 (1)
using appropriate
screws
Fig. 33 (2)
.
Start-up
14 * Depending on model and options