Specifications Sheet
Unit Dimensions
Cabinet Opening Dimensions
Ventilation Requirements
Top Door Hinge Clearance
A
B
C
B - Side view
Cabinet
Refrigerator
A. 2-7/32" (56.5 mm)
B. 71-9/16" (1817 mm)
C. 23-5/8" (600 mm)
D. 25-3/16" (640 mm)
E. 24-3/16" (614 mm)
F. 24-13/16" (630 mm)
G. 46-1/2" (1180 mm)
3"
(76 mm)
*The given cabinet opening height dimension includes space 
for top air vent. If you choose to place the vent above the 
cabinet or in a so t, you will need to adjust the height 
dimensions accordingly. Please refer to Ventilation 
Requirements.
When installing CS units into a row of cabinets or 
wall units: Use these dimensions to achieve a custom 
look with the cabinetry while providing the necessary 
clearance for the top door hinge.
This type of cabinet must be carefully constructed using the correct dimensions and it must provide suitable 
ventilation to ensure proper appliance operation.
Kitchen Cabinet Airfl ow
The following ventilation dimensions must be observed: There must be a ventilation space at least 31 in.² 
(200 cm²) per appliance at the airfl ow inlet (1) and at the airfl ow outlet (2). 
The top ventilation space can be directed in one of the following ways:
A) Directly over the appliance (2) with a gap between the ceiling of the unit and the cabinet.
B) Above the cabinet and below the ceiling (3).
C) Through a vent installed in a so t (4).
The refrigerator is designed to allow proper air fl ow when the appliance is installed up against the wall. 
A minimum space of 1 1/2" (38mm) is required behind any cabinet above the appliance if ventilating 
above that cabinet.
The appliance can be integrated into the kitchen 
units. To adapt the appliance to the height of the 
row of kitchen units, a suitable top cupboard can 
be fi tted above the appliance.
Unit Venting
DO NOT restrict the air fl ow. A cross-sectional 
air fl ow of at least 31" square (200cm ²) must be 
provided. The opening can either be directly over 
the appliance or behind of the cabinet on top of the 
unit (see ventilation requirements). 
The CS models can be installed in standard 24" 
(609mm) deep cabinets. You will only have to make 
sure that the door swing clearance is enough. It is 
possible to push all CS models to the rear wall of the 
cabinet without modifi cation. 
When installing the appliance next to a wall, a distance 
on the hinge side of 1 13/32 inches (36 mm) minimum 
is required between the appliance and the wall to allow 
for the door handle projection when the door is open. 
Minimum Cabinet Opening Dimensions:
A. 23-7/8" (606 mm)
B. 24" (609 mm)
C. 85-29/32" (2182 mm)
D. 78 1/4" (1988)*
24"
Diagrams
Liebherr CS 1210
Freestanding/Semi Built-in