Product Data Sheet / Brochure
6
Vertiv™ Liebert® GXT5 | 750 - 3000VA 230V UPS
Technical Specifications
GXT5-750IRT2UXLE GXT5-1000IRT2UXLE GXT5-1500IRT2UXLE GXT5-2000IRT2UXLE GXT5-3000IRT2UXLE
Ratings (VA/W) 750VA/750W 1000VA/1000W 1500VA/1500W 2000VA/2000W 3000VA/3000W
Dimensions, mm
Unit (W x D x H) 430 x 400 x 85 430 x 400 x 85 430 x 470 x 85 430 x 470 x 85 430 x 540 x 85
Weight, kg
Unit 21 21 21 21 28.20
Input AC Parameters
Range
Typical 230V
Range: 115-288V
Typical 230V
Range: 115-288V
Typical 230V
Range: 115-288V
Typical 230V
Range: 115-288V
Typical 230V
Range: 115-288V
Frequency 40-70Hz; Auto Sensing 40-70Hz; Auto Sensing 40-70Hz; Auto Sensing 40-70Hz; Auto Sensing 40-70Hz; Auto Sensing
Input Power Cord IEC 60320 C14 input socket IEC 60320 C14 input socket IEC 60320 C14 input socket IEC 60320 C20 input socket IEC 60320 C20 input socket
Output AC Parameters
Output Receptacles IEC60320-C13 × 8 IEC60320-C13 × 8 IEC60320-C13 × 8 IEC60320-C13 × 8
IEC60320-C13 × 6
IEC60320-C19 × 1
Typical 230V
User selectable output
200/208/220/230/240VAC
(user-configurable); ±3%
200/208/220/230/240VAC
(user-configurable); ±3%
200/208/220/230/240VAC
(user-configurable); ±3%
200/208/220/230/240VAC
(user-configurable); ±3%
200/208/220/230/240VAC
(user-configurable); ±3%
Waveform Sine wave Sine wave Sine wave Sine wave Sine wave
Utility (AC) Mode
Overload
>200% for 250ms; 150- 200% for 2
seconds; 125- 150% for 50
seconds; 105-125% 60 seconds
>200% for 250ms; 150- 200% for 2
seconds; 125- 150% for 50
seconds; 105-125% 60 seconds
>200% for 250ms; 150- 200% for 2
seconds; 125- 150% for 50
seconds; 105-125% 60 seconds
>200% for 250ms; 150- 200% for 2
seconds; 125- 150% for 50
seconds; 105-125% 60 seconds
>200% for 250ms; 150- 200% for 2
seconds; 125- 150% for 50
seconds; 105-125% 60 seconds
Battery
Typ e
Valve-regulated,
non-spillable, lead acid
Valve-regulated,
non-spillable, lead acid
Valve-regulated,
non-spillable, lead acid
Valve-regulated,
non-spillable, lead acid
Valve-regulated,
non-spillable, lead acid
Backup Time
(100% Load)
8.5 Minutes 6 Minutes 5 Minutes 3 Minutes 3 Minutes
Backup Time
(50% Load)
21.5 Minutes 15 Minutes 13 Minutes 9 Minutes 9 Minutes
+1 External Battery
Cabinet (100% Load)
41 Minutes 28.5 Minutes 25 Minutes 17 Minutes 17 Minutes
+1 External Battery
Cabinet (50% Load)
88 Minutes 65 Minutes 59 Minutes 42 Minutes 43.5 Minutes
Environmental Requirements
Operating Temperature,
°C
0 to 40 °C 0 to 40 °C 0 to 40 °C 0 to 40 °C 0 to 40 °C
Storage Temperature,
°C
-20 to 60 °C
contain batteries will be
from -15 to 40°C.
-20 to 60 °C
contain batteries will be
from -15 to 40°C.
-20 to 60 °C
contain batteries will be
from -15 to 40°C.
-20 to 60 °C
contain batteries will be
from -15 to 40°C.
-20 to 60 °C
contain batteries will be
from -15 to 40°C.
Relative Humidity
0% to 95%,
non-condensing
0% to 95%,
non-condensing
0% to 95%,
non-condensing
0% to 95%,
non-condensing
0% to 95%,
non-condensing
Operating Elevation
3,000m 3,000m 3,000m 3,000m 3,000m
Storage Elevation
15 000m 15 000m 15 000m 15 000m 15 000m
Audible Noise
<46dBA max at 1m front and sides
< 43dBA at 1m rear
<46dBA max at 1m front and sides
< 43dBA at 1m rear
<46dBA max at 1m front and sides
< 43dBA at 1m rear
<48dBA max at 1m front and side
<48dBA max at 1m rear
<48dBA max at 1m front and side
<48dBA max at 1m rear
Agency
Surge Immunity
ANSI C62.41 Category B ANSI C62.41 Category B ANSI C62.41 Category B ANSI C62.41 Category B ANSI C62.41 Category B
Transportation ISTA Procedure 1A ISTA Procedure 1A ISTA Procedure 1A ISTA Procedure 1A ISTA Procedure 1A
Safety EN 62040-1:2008+A1:2013 EN 62040-1:2008+A1:2013 EN 62040-1:2008+A1:2013 EN 62040-1:2008+A1:2013 EN 62040-1:2008+A1:2013
Emissions
EN 62040-2:2006
EN 61000-3-2:2014
EN 61000-3-3:2013
EN 62040-2:2006
EN 61000-3-2:2014
EN 61000-3-3:2013
EN 62040-2:2006
EN 61000-3-2:2014
EN 61000-3-3:2013
EN 62040-2:2006
EN 61000-3-2:2014
EN 61000-3-3:2013
EN 62040-2:2006
EN 61000-3-2:2014
EN 61000-3-3:2013
Environmental
WEEE and ROHS2
REACH
WEEE and ROHS2
REACH
WEEE and ROHS2
REACH
WEEE and ROHS2
REACH
WEEE and ROHS2
REACH
Warranty
Warranty