Submittal Sheet
Table Of Contents
LowPro-Series_P5
R3/25/2019 © Copyright 2019 Liberty Pumps, Inc.
All rights reserved.
Specifications subject to change without notice.
9.01 CONTROLS
All units are supplied with CSA and UL approved float switches.
10.01 PAINT
The exterior of the pump casting shall be protected with powder coat paint.
11.01 SUPPORT
The pump shall have cast iron support legs, enabling it to be a free standing unit. The legs will be high enough to allow 2” solids to enter
the volute.
12.01 SERVICEABILITY
Components required for the repair of the pump shall be shipped within a period of 24 hours.
13.01 TESTING
The pump shall have a ground continuity check and the motor chamber shall be hi-potted to test for electrical integrity, moisture content,
and insulation defects. The motor and volute housing shall be pressurized and an air leak decay test performed to ensure integrity of the
motor housing. The pump shall be run, voltage current monitored, and checked for noise or other malfunction.
14.01 QUALITY CONTROL
The pump shall be manufactured in an ISO 9001 certified facility.
15.01 WARRANTY
Standard limited warranty shall be 3 years.