LG VRF Systems
23 24
LG Air Conditioning Technologies
MULTI V S
Specifications Unit ARUN024GSS4 ARUN038GSS4 ARUN048GSS4 ARUN053GSS4 ARUB060GSS4
Tons 2 3 4 4.4 5
Nominal Capacity
Cooling
1
Btu/h 24,000 39,500 50,000 55,500 60,000
Heating
1
Btu/h 27,000 44,000 56,500 61,500 64,000
Rated Capacity
Cooling
2
Btu/h 24,000 38,000 48,000 53,000 60,000
Heating
2
Btu/h 27,000 42,000 54,500 59,000 64,000
Power Voltage V / Hz / ø 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1
Power/Communication Wiring No x AWG 2 x 18 2 x 18 2 x 18 2 x 18 2 x 18
Operating Range
Cooling ˚F 23 - 122 23 - 122 23 - 122 23 - 122 23 - 122
Heating ˚F -4 - 61 -4 - 61 -4 - 61 -4 - 61 -13 - 61
Dimensions (W×D×H) Body in 37-13/32 x 32-27/32 x 13 37-13/32 x 32-27/32 x 13 37-13/32 x 32-27/32 x 13 37-13/32 x 32-27/32 x 13 37-13/32 x 32-27/32 x 13
Weight
Net lbs 159 207 207 207 256
Shipping lbs 176 218 218 218 284
Sound Pressure
4
dB(A) 50 50 51 52 57
Fan (Axial Flow Fan) CFM 2,119 3,885 3,885 3,885 3,885
Compressor
Type DC Inverter DC Inverter DC Inverter DC Inverter DC Inverter
Oil Type PVE/FVC68D PVE/FVC68D PVE/FVC68D PVE/FVC68D PVE/FVC68D
Quantity 1 1 1 1 1
Heat Exhanger
Coating Gold Fin / Hydrophillic Gold Fin / Hydrophillic Gold Fin / Hydrophillic Gold Fin / Hydrophillic Gold Fin / Hydrophillic
Rows/Fins per Inch 2/14 2/14 2/14 2/14 3/14
Piping
Liquid Line in 3/8 3/8 3/8 3/8 3/8
H/P Vapor Line in - - - - 5/8
L/P Vapor Line in 5/8 5/8 5/8 3/4 3/4
Refrigerant
Type R410A R410A R410A R410A R410A
Charge lbs 4.0 6.6 6.6 6.6 8.8
Control EEV EEV EEV EEV EEV
Maximum Number of Indoor Units
3
4 6 8 9 12
1. Nominal capacity applied with non-ducted indoor units, and is rated 0 ft. above sea level with 25 ft. of refrigerant line per indoor unit
and a 0 ft. level difference between outdoor and indoor units. All capacities are net with a Combination Ratio between 95 and 105%.
Cooling: Indoor 80°F DB, 67°F WB; Outdoor 95°F DB, 75°F WB
Heating: Outdoor 70°F DB, 59°F WB; Outdoor 47°F DB, 43°F WB
2. Rated capacity is certified under AHRI Standard 1230. See www.ahrinet.org for information.
3. The System Combination Ratio must be between 50 and 130%.
4. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745.
5. Due to our commitment to continued innovation, some specications may be changed without notification.
1. Nominal capacity applied with non-ducted indoor units, and is rated 0 ft. above sea level with 25 ft. of refrigerant line per indoor unit
and a 0 ft. level difference between outdoor and indoor units. All capacities are net with a Combination Ratio between 95 and 105%.
Cooling: Indoor 80°F DB, 67°F WB; Outdoor 95°F DB, 75°F WB
Heating: Outdoor 70°F DB, 59°F WB; Outdoor 47°F DB, 43°F WB
2. Rated capacity is certified under AHRI Standard 1230. See www.ahrinet.org for information.
3. The System Combination Ratio must be between 50 and 130%.
4. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745.
5. Due to our commitment to continued innovation, some specications may be changed without notification.
ARU*****GSS4
MULTI V S
MULTI V SPACE II
Specifications Unit ARUN053GF2
Tons 4.4
Nominal Capacity
Cooling
1
Btu/h 53,000
Heating
1
Btu/h 59,000
Rated Capacity
Cooling
2
Btu/h 54,000
Heating
2
Btu/h 60,000
Power Voltage V / Hz / ø 208-230/60/1
Power/Communication Wiring No x AWG 2 x 18
Operating Range
Cooling ˚F 23 - 118
Heating ˚F -4 - +60
Dimensions (W×D×H) Body in 29-1/2 x 70-1/2 x 25-1/2
Weight
Net lbs 320
Shipping lbs 346
Sound Pressure
4
dB(A) 68.3 / 52.7
Fan (Propeller) CFM 3,532
Compressor (DC Inverter)
Oil Type PVE/FVC68D
Quantity 1
Heat Exhanger
Coating Gold Fin
Rows/Fins per Inch 2/14
Piping
Liquid Line in 3/8
Vapor Line in 3/4
Refrigerant
Type R410A
Charge lbs 7.7
Control EEV
Maximum Number of Indoor Units
3
9
ARUN053GF2
MULTI V SPACE II