Owner's Manual

22 Ventilator
Maintenance and Service
Replacement of the Humidifier
1. Remove the maintenance cover.
Loosen the screw (8EA) and detach the
maintenance cover.
2. Prepare to replace the Humidifier.
• Uncork the Drain Cap to drain the remain-
ing water in the feed cistern.
• Loosen the screw (3EA) and detach the lid
of feed cistern.
• Loosen the screw (1EA) and Detach the
clamp.
3. Pull out the Humidifier (2EA)
• Uncork the Drain Cap to drain the remain-
ing water in the feed cistern.
• Loosen the screw (3EA) and detach the lid
of feed cistern.
• Loosen the screw (1EA) and Detach the
clamp.
4. Insert the new Humidifier (2EA)
Confirm that the edge of top panel of humidi-
fier element has been hooked securely on
the rail.
And assemble the lamp, rid of cistern
and drain cap.
WARNING: Turn the breaker off when
cleaning the product.
CAUTION: Gloves should be worn
when doing the maintenance work.
Screw
Maintenance
cover
Screw
Screw
Clamp
Drain Cap
Lid of feed
cistern
Humidifier
Rail