FLEX MULTI-SPLIT •
DUAL-, TRI-, & QUAD ZONE
FLEX MULTI-SPLIT
SYSTEM
Accessory
Electrical & Refrigeration • Quick reference
Wired Wall Thermostat for Flex-Multi Split System
Zone Type Model Voltage Running Current MCA MOP
Indoor Outdoor
Flex Multi-Split
Indoor Units
H/P LMN096HVT 208/230 - 0.20 - -
H/P LMAN096HVT 208/230 - 0.15 - -
H/P LMDN095HV 208/230 - 0.25 - -
H/P LMN126HVT 208/230 - 0.20 - -
H/P LMAN126HVT 208/230 - 0.15 - -
H/P LMDN125HV 208/230 - 0.25 - -
H/P LMCN125HV 208/230 - 0.25 - -
H/P LMN186HVT 208/230 - 0.30 - -
H/P LMAN186HVT 208/230 - 0.15 - -
H/P LMDN185HV 208/230 - 0.25 - -
H/P LMCN185HV 208/230 - 0.25 - -
Outdoor Units
H/P LMU187HV - 208/230 - 15 15
H/P LMU247HV - 208/230 - 20 25
H/P LMU369HV - 208/230 - 30 35
System Combined With
Nominal
Cooling
Capacity
EER
Indoor
SEER
Nominal
Heating
Capacity
COP
Low
Heating
Capacity
COP HSPF
LMU187HV
Non-Ducted Indoor Unit 15,600 14.00 21.0 17,000 3.90 10,000 2.7 9.20 Yes
Ducted Indoor Unit 14,800 11.90 17.7 16,800 3.80 9,900 2.6 8.80
-
Mixed Ducted & Non-Ducted
15,200 12.95 19.4 16,900 3.85 9,950 2.7 9.00
-
LMU247HV
Non-Ducted Indoor Unit 19,200 13.40 21.7 26,400 3.50 16,500 2.6 9.40 Yes
Ducted Indoor Unit 18,000 11.80 16.4 26,200 3.40 16,400 2.6 8.50
-
Mixed Ducted & Non-Ducted
18,600 12.60 19.1 26,300 3.45 16,450 2.6 8.95
-
LMU369HV
Non-Ducted Indoor Unit 34,000 12.50 17.5 41,000 3.40 23,300 2.4 10.5 Ye s
Ducted Indoor Unit 34,000 12.00 16.5 41,000 3.20 25,300 2.6 9.5
-
Mixed Ducted & Non-Ducted
34,000 12.25 17.0 41,000 3.30 24,300 2.5 9.5
-
Type Model Pipe Size Additional Max. Length Max.
Liquid Suction Refrigerant Each Pipe Elevation
Flex Multi-Split
H/P LMN096HVT 1/4” 3/8” 0.22 oz./ft. 82’ 49’
H/P LMAN095HVT 1/4” 3/8” 0.22 oz./ft. 82’ 49’
H/P LMDN095HV 1/4” 3/8” 0.22 oz./ft. 82’ 49’
H/P LMN126HVT 1/4” 3/8” 0.22 oz./ft. 82’ 49’
H/P LMAN125HVT 1/4” 3/8” 0.22 oz./ft. 82’ 49’
H/P LMDN125HV 1/4” 3/8” 0.22 oz./ft. 82’ 49’
H/P LMCN125HV 1/4” 3/8” 0.22 oz./ft. 82’ 49’
H/P LMN186HVT 1/4” 1/2” 0.22 oz./ft. 82’ 49’
H/P LMAN185HVT 1/4” 1/2” 0.22 oz./ft. 82’ 49’
H/P LMDN185HV 1/4” 1/2” 0.22 oz./ft. 82’ 49’
H/P LMCN185HV 1/4” 1/2” 0.22 oz./ft. 82’ 49’
Electrical Specifications
Refrigerant Line & Formula Specifications
All equipment are single phase.
NOTE: Please see local electrical codes for proper wire specifications.
Please choose a proper wire size based on local and state code
* Non-Ducted Indoor Unit Test Condition : Standard Indoor Combination
* Low Heating Capacity : Outdoor Temperature 17
PI485 V-net control integration accessory.
Control integration to LG V-net controls
(AC Smart, ACP, BACnet, LonWorks, etc.)
Applied to Inverter Flex Multi (dual, tri, and quad zone) and
Single Inverter Ceiling Cassette.
Model # : PMNFP14A0
PQRCVSL0 PQRCVSL0QW