ENGLISH FRANCAIS ESPAÑOL OWNER’S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. TYPE : WALL MOUNTED Applied Models : AS-W243DGY9 AS-W303DGY9 AS-W363DGY9 P/NO : MFL39817422 http://www.lghvac.com www.lg.
Room Air Conditioner Owner’s Manual TABLE OF CONTENTS A. Safety Precautions ..............................3 B. Electrical Safety...................................6 Temporary Use of an Adapter ...............6 Symbols used in this Manual.................6 C. Product Introduction...........................7 Indoor Units ...........................................7 Operation Indication Lamps ..................7 Outdoor Unit ..........................................7 D. Operating Instructions................
Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. ■ Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications. This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage. ■ Meanings of symbols used in this manual are as shown below. Be sure not to do. Be sure to follow the instruction.
Safety Precautions Indoor/outdoor wiring connections must be secured tightly and the cable should be routed properly so that there is no force pulling the cable from the connection terminals. Safely dispose off the packing materials. Like screws, nails, batteries, broken things etc after installation or svc and then tear away and thraw away the plastic packaging bags. • Improper or loose connections can cause heat generation or fire. • Children may play with them and cause injury.
Safety Precautions • There is risk of damage or loss of property. Do not touch the metal parts of the product when removing the air filter. • There is risk of personal injury. Do not insert hands or other objects through the air inlet or outlet while the product is operating. • There are sharp and moving parts that could cause personal injury. Do not tilt the unit when removing or uninstalling it. • The condensed water inside can spill .
Electrical Safety Electrical Safety • This appliance must be properly grounded. To minimize the risk of electric shock, you must alway plug into a grounded oulet. • Do not cut or remove the grounding prong from the power plug. • Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal and not insulated, and the wall receptacle is grounded through the house wiring.
Product Introduction Here is a brief introduction of the indoor and outdoor units. Please see the information specific to your indoor unit type. Indoor Units Air Inlet Front Panel Air Filter Signal Receptor On/Off button Plasma filter Operation Indication Lamps On/Off : Lights up during the system operation, error code and auto restart setting. Sleep mode : Lights up during sleep mode auto operation.
Operating Instructions Operating Instructions How to insert the Batteries 1. Remove the battery cover by pulling it according to the arrow direction. 2. Insert new batteries making sure that the (+) and (-) of battery are installed correctly. 3. Reattach the cover by sliding it back into position. NOTE 1. Always use/replace both batteries of same type. 2. If the system is not to be used for a long time, remove the batteries to save their working life. 3.
Operating Instructions The controls will look like the following. Signal transmitter 5 1 6 3 4 10 2 7 11 8 13 CANCEL ON OFF 9 12 SET AUTO CLEAN 17 18 14 16 15 Flip-up door (opened) Operation Mode Cooling Operation Auto Operation or Auto Changeover Healthy Dehumidification Operation Heating Operation • Cooling Model( ), Heat Pump Model( ) 1. START/STOP BUTTON Used to turn off/on the unit. 2. OPERATION MODE SELECTION BUTTON Used to select the operation mode. 3.
Operating Instructions Operation Mode 1 3 1 Press the START/STOP BUTTON to turn the unit on. The unit will respond with a beep. 2 Open the door of the remote controller and press the operation mode button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow.
Operating Instructions Healthy Dehumidification During Healthy Dehumidification Operation ❏ If you select the dehumidification mode on the OPERATION MODE SELECTION BUTTON, the product starts to run the dehumidification function. It automatically sets the room temperature and airflow volume to the best condition for dehumidification, based on the sensed current room temperature.
Operating Instructions Jet Cool/Heat Operation Jet cool function can be used to cool the room quickly in hot summer. When this function is turned on, the air conditioner runs in cooling operation mode with super high fan speed and 18°C(64°F) setting temperature for 30 minutes for fast and effective cooling. Similarly, jet heat function (available only in some models) warms up the room quickly by operating at super high fan speed and 30°C(86°F) setting temperature for 60 minutes.
Operating Instructions Energy-saving cooling mode can save energy in cooling and healthy dehumidification operation, because it can operate efficiently by setting body-adaptation time according to the change of time and temperature and adjusting automatically desired temperature. 1. Press the START/STOP BUTTON to start the unit. 2. Open the door on the remote controller. Select cooling operation or healthy dehumidification operation. 3. Press the ENERGY-SAVING COOLING MODE BUTTON. 4.
Operating Instructions Sleep Mode 1. Press the SLEEP MODE AUTO BUTTON to set the time when you want the unit to stop automatically. 2. The timer is programmed in one-hour increments by pressing the SLEEP MODE AUTO BUTTON 1 to 7 times. The sleep mode is available for 1 to 7 times. To alter the time period in steps of 1 hour, press the SLEEP MODE AUTO BUTTON while aiming at air conditioner. 3. • (In case of non-Inverter Model) Make sure the sleep mode LED lights up.
Operating Instructions The up/down airflow (Vertical airflow) can be adjusted by using the remote controller. The left/right(Horizontal airflow) can be adjusted by using the remote control. 1. Press the START/STOP BUTTON to start the unit. 1. Press the START/STOP BUTTON to start the unit. 2. Press CHAOS SWING BUTTON. 2. Press the HORIZONTAL AIRFLOW DIRECTION BUTTON. 3. The louvers will swing up & down automatically. 4. To stop the louver at a desired angle, press again 3.
Maintenance and Service Maintenance and Service Before performing any maintenance, turn off the main power to the system, disconnect the circuit breaker and unplug the power cord. Indoor Unit Clean the unit with a soft dry cloth. Do not use bleach or abrasives. Never use any of these • Water hotter than 40°C(104°F). It may cause deformation and discoloration. • Volatile substances. They may damage the surface of the air conditioner.
Maintenance and Service The heat exchanger coils and panel vents of the outdoor unit should be checked regularly. If clogged with dirt or soot, the heat exchanger and panel vents may be professionally steam cleaned. NOTE Dirty or clogged coils will reduce the operating efficiency of the system and cause higher operating costs.
Maintenance and Service Troubleshooting Tips! Save time and money! The air conditioner may be operating abnormally when: Problem Air conditioner does not start Possible Causes n The air conditioner is unplugged. n The fuse is blown/circuit breaker is tripped. n Power failure. n High voltage. n Airflow is restricted. n The air filter is dirty. Air conditioner does not cool as it should n The room may have been hot. n Cold air is escaping. n Check the temperature settings.
LG Customer Information Center Applied Models : AS-W243DGY9 AS-W303DGY9 AS-W363DGY9 LGEUS LG Electronics, Air conditioning Division 1000 Sylvan Ave., Englewood Cliffs, NJ 07632 LGECI LG Electronics Canada Inc. 20 NORELCO DRIVE. NORTH YORK, ONTARIO M9L 2X6. US CANADA 888-865-3026 888-865-3026 1-888-LG-Canada USA, press #2 for PTAC, TTW USA, press #3 for DFS, Multi V CANADA Register your product Online! www.lg.com 1.