High Efciency
Single Zone Inverter
Electrical & Refrigeration
Quick Reference
*Minimum Circuit Ampacity
**Maximum Overcurrent Protection
All equipment single phase.
NOTE: Please see local electrical codes for proper wire specifications.
PQRCVSL0 PQRCVSL0QW
Wired Wall Thermostat for Single Zone Inverter.
(Applicable to LS307HV2, LS360HV2, LXXXXHSV2 and LSXXXHYV
models only)
*** Each system is pre-charged with enough refrigerant to charge 25 ft. (41 ft. for LA090HSV2,
LA120HSV2, LS091HSV2, LS121HSV2) of line and the interior unit.
Please choose a proper wire size based on local and state code
Electrical Specifications
Type Model BTUs Voltage Rated MCA* MOP**
Zone Indoor Outdoor Amps
High Efciency
Art Cool™
Mirror
Single Zone
H/P LA090HSV2 9,000 230/208 230/208 8.5 10 15
H/P LA120HSV2 11,200 230/208 230/208 8.5 10 15
H/P LA180HSV2 18,200 230/208 230/208 17.0 19 30
H/P LA240HSV2 22,000 230/208 230/208 17.0 19 30
High Efciency
Single Zone
H/P LS091HSV2 9,000 230/208 230/208 8.1 10 15
H/P LS121HSV2 11,200 230/208 230/208 8.1 10 15
H/P LS181HSV2 18,200 230/208 230/208 15.4 19 30
H/P LS240HSV2 22,000 230/208 230/208 15.4 19 30
Refrigerant Line Specifications***
Type Model BTUs Pipe Size Additional Max. Pipe Max.
Zone Liquid Suction Refrigerant Length Elevation
High Efciency
Art Cool™ Mirror
Single Zone
H/P LA090HSV2 9,000 1/4” 3/8” 0.22 oz./ft. 65’ 32’
H/P LA120HSV2 11,200 1/4” 3/8” 0.22 oz./ft. 65’ 32’
H/P LA180HSV2 18,200 3/8” 5/8” 0.38 oz./ft. 98’ 49’
H/P LA240HSV2 22,000 3/8” 5/8” 0.38 oz./ft. 98’ 49’
High Efciency
Single Zone
H/P LS091HSV2 9,000 1/4” 3/8” 0.22 oz./ft. 65’ 32’
H/P LS121HSV2 11,200 1/4” 3/8” 0.22 oz./ft. 65’ 32’
H/P LS181HSV2 18,200 3/8” 5/8” 0.38 oz./ft. 98’ 49’
H/P LS240HSV2 22,000 3/8” 5/8” 0.38 oz./ft. 98’ 49’
Accessory