Mega Engineering Manual

Due to our policy of continuous product innovation, some specications may change without notication.
© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp.
54 | PERFORMANCE DATA
Single Zone Mega, Standard E󰀩ciency, and Mega 115V Wall Mounted Engineering Manual
Table 18: LSN180HEV2 / LSU180HEV2 Cooling Capacities.
Outdoor
Air
Temp.
(°F DB)
Indoor Air Temperature (°F DB / °F WB)
64 / 53 68 / 57 72 / 61 77 / 64 80 / 67 86 / 72 90 / 75
TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14 11.02 8.76 0.64 13.78 9.32 0.76 16.54 9.89 0.87 19.99 10.60 1.02 22.06 11.03 1.11 18.41 12.03 0.90 15.97 12.69 0.77
23 11.83 9.40 0.63 14.23 10.01 0.76 16.63 10.62 0.89 19.64 11.38 1.06 21.44 11.84 1.16 18.86 12.91 0.92 17.15 13.63 0.77
25 12.02 9.55 0.65 14.37 10.14 0.78 16.72 10.73 0.91 19.65 11.47 1.07 21.42 11.91 1.16 19.07 13.05 0.94 17.51 13.81 0.79
30 12.48 9.92 0.70 14.70 10.47 0.82 16.92 11.01 0.93 19.70 11.69 1.08 21.37 12.10 1.17 19.59 13.40 0.98 18.41 14.26 0.85
35 12.95 10.29 0.74 15.04 10.79 0.85 17.13 11.29 0.96 19.75 11.92 1.10 21.31 12.29 1.18 20.11 13.74 1.01 19.31 14.71 0.90
40 13.41 10.66 0.79 15.37 11.12 0.89 17.34 11.57 0.99 19.79 12.14 1.12 21.26 12.49 1.19 20.63 14.09 1.05 20.21 15.16 0.96
45 13.87 11.03 0.84 15.71 11.44 0.93 17.54 11.85 1.02 19.84 12.37 1.13 21.21 12.68 1.20 21.15 14.44 1.09 21.10 15.61 1.02
50 14.34 11.40 0.89 16.04 11.76 0.97 17.75 12.13 1.05 19.88 12.59 1.15 21.16 12.87 1.21 21.67 14.79 1.13 22.00 16.06 1.07
55 14.80 11.77 0.93 16.38 12.09 1.00 17.96 12.41 1.08 19.93 12.82 1.16 21.11 13.06 1.22 22.19 15.13 1.16 22.90 16.51 1.13
60 15.27 12.13 0.98 16.72 12.41 1.04 18.16 12.69 1.10 19.97 13.04 1.18 21.06 13.25 1.23 22.70 15.48 1.20 23.80 16.97 1.18
65 15.13 12.02 1.03 16.50 12.36 1.09 17.88 12.70 1.15 19.59 13.12 1.22 20.62 13.38 1.27 22.27 15.49 1.25 23.36 16.90 1.25
70 14.99 11.92 1.08 16.29 12.31 1.14 17.59 12.71 1.19 19.21 13.21 1.26 20.19 13.51 1.31 21.83 15.50 1.31 22.92 16.82 1.31
75 14.85 11.81 1.13 16.07 12.26 1.18 17.30 12.72 1.24 18.83 13.29 1.30 19.75 13.63 1.34 21.39 15.51 1.36 22.48 16.75 1.37
80 14.71 11.70 1.18 15.86 12.21 1.23 17.01 12.73 1.28 18.45 13.37 1.34 19.31 13.76 1.38 20.95 15.52 1.41 22.04 16.68 1.43
85 14.57 11.59 1.23 15.65 12.16 1.28 16.72 12.74 1.33 18.07 13.46 1.39 18.87 13.89 1.42 20.51 15.52 1.46 21.60 16.61 1.49
90 14.43 11.48 1.28 15.43 12.11 1.32 16.43 12.75 1.37 17.69 13.54 1.43 18.44 14.02 1.46 20.07 15.53 1.51 21.16 16.54 1.55
95 14.29 11.37 1.33 15.22 12.06 1.37 16.15 12.76 1.41 17.31 13.62 1.47 18.00 14�15 1.50 19.63 15.54 1.57 20.72 16.47 1.61
100 13.92 11.07 1.35 14.87 11.80 1.39 15.82 12.52 1.44 17.01 13.43 1.49 17.72 13.98 1.52 19.30 15.29 1.59 20.35 16.17 1.63
105 13.55 10.77 1.37 14.52 11.53 1.41 15.49 12.29 1.46 16.71 13.24 1.51 17.44 13.81 1.55 18.96 15.05 1.61 19.97 15.87 1.66
110 13.17 10.47 1.39 14.17 11.26 1.43 15.17 12.05 1.48 16.41 13.04 1.53 17.16 13.64 1.57 18.62 14.80 1.63 19.60 15.58 1.68
115 12.70 10.10 1.41 13.67 10.87 1.45 14.63 11.64 1.49 15.84 12.60 1.55 16.56 13.18 1.58 17.99 14.30 1.65 18.94 15.05 1.70
118 12.42 9.87 1.41 13.37 10.63 1.46 14.31 11.39 1.50 15.49 12.33 1.56 16.20 12.90 1.59 17.60 14.00 1.67 18.54 14.74 1.71
122 12.05 10.07 1.43 12.96 10.84 1.47 13.88 11.61 1.52 15.03 12.58 1.58 15.71 13.16 1.61 17.08 14.28 1.68 17.98 15.03 1.73
Cooling Capacity Table for LS180HEV2 (LSU180HEV2 + LSN180HEV2)
DB: Dry Bulb Temperature (°F) WB: Wet Bulb Temperature (°F) TC: Total Capacity (kBtu/h)
SHC: Sensible Capacity (kBtu/h) PI: Power Input (kW) (includes compressor, indoor fan motor and
outdoor fan motor)
1. All capacities are net, evaporator fan motor heat is deducted.
2. Grey shading indicates reference data. When operating at this temperature, these values can be
different if the system is not running consistently..
3. Direct interpolation is permissible. Do not extrapolate.
Capacity as rated: 0 ft. above sea level with 24.6 ft. of refrigerant piping. 0 ft. level difference between
outdoor and indoor units.
Cooling capacity rating obtained with air entering the indoor unit at 80ºF dry bulb (DB) and 67ºF wet
bulb (WB), and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB).
PERFORMANCE DATA
Cooling Capacity