ACOUSTIC DATA
Outdoor Units
Measurements are taken 3.3 ft away from the front of the unit.
Sound pressure levels are measured in dB(A) with a tolerance of
±1.
Data is valid at nominal operation conditions. Operating conditions
are assumed to be standard.
Reference acoustic pressure 0dB=20μPa
Sound pressure levels are tested in an anechoic chamber under
ISO Standard 3745, and may be different according to the test
condition or equipment.
Sound level will vary depending on a range of factors including the
construction (acoustic absorption coefficient) of a particular room in
which the unit was installed.
Figure 12: High Efciency Outdoor Unit Sound Level Measurement.
Table 7: High Efciency Wall Mount Outdoor Unit Acoustic Data.
3.3 ft. (1)
Center of
Outdoor Unit
Unit : ft. (m)
Model
Sound Pressure Levels (dB[A])
Cooling (Max.) Heating (Max.)
LSU090HSV5
47 51
LSU120HSV5
47 51
LSU181HSV5
55 55
Outdoor Unit Sound Pressure Measurement
Outdoor Unit Sound Pressure Levels
LSU090HSV5/ LSU120HSV5 Cooling and Heating Sound Pressure Diagrams
Figure 13: LSU090/120HSV5 Cooling Sound Pressure Level Diagram.
Figure 14: LSU090/120HSV5 Heating Sound Pressure Level Diagram.