Mega 115V Installation Manual
6LQJOH=RQH0HJDDQG0HJD9:DOO0RXQWHG,QVWDOODWLRQ0DQXDO
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
6$)(7<,16758&7,216
,167$//$7,21&217,18('
'RQ¶WLQVWDOOWKHXQLWZKHUHLW¶VGLUHFWO\H[SRVHGWRRFHDQ
ZLQGV
Ocean winds will cause corrosion, particularly on the condenser and
HYDSRUDWRU¿QVZKLFK LQ WXUQ FRXOG FDXVH SURGXFW PDOIXQFWLRQ RULQHI-
¿FLHQWSHUIRUPDQFH
:KHQLQVWDOOLQJWKHXQLWLQDORZO\LQJDUHDRUDORFDWLRQWKDW
LVQRWOHYHOXVHDUDLVHGFRQFUHWHSDGRUFRQFUHWHEORFNVWR
SURYLGHDVROLGOHYHOIRXQGDWLRQ
This will prevent water damage and reduce abnormal vibration.
3URSHUO\LQVXODWHDOOFROGVXUIDFHVWRSUHYHQW³VZHDWLQJ´
Cold surfaces such as uninsulated piping can generate condensate that
will drip and cause a slippery surface condition and/or water damage to
walls.
:KHQLQVWDOOLQJWKHXQLWLQDKRVSLWDOPHFKDQLFDOURRPRU
VLPLODUHOHFWURPDJQHWLF¿HOG(0)VHQVLWLYHHQYLURQPHQW
SURYLGHVXႈFLHQWSURWHFWLRQDJDLQVWHOHFWULFDOQRLVH
Inverter equipment, power generators, high-frequency medical equipment,
or radio communication equipment will cause the air conditioner to operate
improperly. The unit will also affect such equipment by creating electrical
noise that disturbs medical treatment or image broadcasting.
'RQRWXVHWKHSURGXFWIRUVSHFLDOSXUSRVHVVXFKDV
SUHVHUYLQJIRRGVZRUNVRIDUWZLQHFRROHUVRURWKHU
SUHFLVLRQDLUFRQGLWLRQLQJDSSOLFDWLRQV7KHHTXLSPHQWLV
GHVLJQHGWRSURYLGHFRPIRUWFRROLQJDQGKHDWLQJ
There is risk of property damage.
'RQRWPDNHUHIULJHUDQWVXEVWLWXWLRQV8VH5$RQO\
If a different refrigerant is used, or air mixes with original refrigerant, the
unit will malfunction and be damaged.
.HHSWKHXQLWXSULJKWGXULQJLQVWDOODWLRQWRDYRLGYLEUDWLRQRU
ZDWHUOHDNDJH
'RQRWLQVWDOOWKHXQLWLQDQRLVHVHQVLWLYHDUHD
:KHQFRQQHFWLQJUHIULJHUDQWWXELQJUHPHPEHUWRDOORZIRU
SLSHH[SDQVLRQ
Improper piping will cause refrigerant leaks and system malfunction.
7DNHDSSURSULDWHDFWLRQVDWWKHHQGRI+9$&HTXLSPHQWOLIH
WRUHFRYHUUHF\FOHUHFODLPRUGHVWUR\5$UHIULJHUDQW
DFFRUGLQJWRDSSOLFDEOH86(QYLURQPHQWDO3URWHFWLRQ
$JHQF\(3$UXOHV
3HULRGLFDOO\FKHFNWKDWWKHRXWGRRUIUDPHLVQRWGDPDJHG
There is a risk of equipment damage.
,QVWDOOWKHXQLWLQDVDIHORFDWLRQZKHUHQRERG\FDQVWHSRQRU
IDOORQWRLW
'RQRWLQVWDOOWKHXQLWRQDGHIHFWLYHVWDQG
There is risk of unit and property damage.
,QVWDOOWKHGUDLQKRVHWRHQVXUHDGHTXDWHGUDLQDJH
There is a risk of water leakage and property damage.
'RQ¶WVWRUHRUXVHÀDPPDEOHJDVFRPEXVWLEOHVQHDUWKH
XQLW
There is risk of product failure.
$OZD\VFKHFNIRUV\VWHPUHIULJHUDQWOHDNVDIWHUWKHXQLWKDV
EHHQLQVWDOOHGRUVHUYLFHG
Low refrigerant levels will cause product failure
7KHXQLWLVVKLSSHGZLWKUHIULJHUDQWDQGWKHVHUYLFHYDOYHV
FORVHG
'RQRWRSHQVHUYLFHYDOYHVRQWKHXQLWXQWLODOO
QRQFRQGHQVLEOHVKDYHEHHQUHPRYHGIURPWKHSLSLQJV\VWHP
DQGDXWKRUL]DWLRQWRGRVRKDVEHHQREWDLQHGIURPWKHFRP
PLVVLRQLQJDJHQW
There is a risk of refrigerant contamination, refrigerant loss and equip-
ment damage.
'RQRWUXQWKHFRPSUHVVRUZLWKWKHVHUYLFHYDOYHVFORVHG
There is a risk of equipment damage.
%HYHU\FDUHIXOZKHQWUDQVSRUWLQJWKHSURGXFW)DLOXUHWRIROORZWKHVHGLUHFWLRQVZLOOUHVXOWLQPLQRURUPRGHUDWHSK\VLFDOLQMXU\
• Do not attempt to carry the product without assistance.
• Some products use polypropylene bands for packaging. Do not use polypropylene bands to lift the unit.
• Suspend the unit from the base at specified positions.
• Support the unit a minimum of four points to avoid slippage from rigging apparatus.
,IWKHDLUFRQGLWLRQHULVLQVWDOOHGLQDVPDOOVSDFHWDNH
PHDVXUHVWRSUHYHQWWKHUHIULJHUDQWFRQFHQWUDWLRQIURP
H[FHHGLQJVDIHW\OLPLWVLQWKHHYHQWRIDUHIULJHUDQWOHDN
Consult the latest edition of ASHRAE (American Society of Heating,
Refrigerating, and Air Conditioning Engineers) Standard 15. If the
refrigerant leaks and safety limits are exceeded, it could result in personal
injuries or death from oxygen depletion.
,QVWDOOWKHXQLWLQDVDIHORFDWLRQZKHUHQRERG\FDQVWHSRQRU
IDOORQWRLW
There is risk of physical injury or death.
3URSHUO\LQVXODWHDOOFROGVXUIDFHVWRSUHYHQW³VZHDWLQJ´
Cold surfaces such as uninsulated piping can generate condensate that
could drip, causing a slippery surface that creates a risk of slipping, falling,