Installation Manual
12
ELECTRICAL CONNECTIONS
4-WIRE CONNECTION: CONDUIT
-   Failure to do so can result in electrical shock, 
severe personal injury or death.
 WARNING
1. Follow the instructions  under “Install the conduit as 
follows” on page 11 to correctly install the strain relief. 
DO NOT install the conduit without a strain relief.
2. Loosen the 2 lower  left and right  screws from  the 
terminal block. (Refer to Figure 12.) Remove the lower 
2 center screws.
3. Remove ground strap and discard as shown in Figure 
12. Do not discard any screws.
4. Attach  the  ground bare wire (green) end to range 
frame and secure it in place with  the ground screw 
(Refer to figure 12.)
5. Insert the bare wire (white/neutral) end through the 
center terminal block opening.
6. Insert the two side bare wire ends into the left and the 
right terminal block opening. Tighten the 3 screws 
securely  into the  terminal  block.  (approximately  
35 - 50 IN-LB)
7. Refer to page 13.
4-wire connection
Remove 
ground
strap and 
discard
Terminal 
block
Wire 
ends
Conduit
connection plate
Black White Red
Ground 
strap
Ground 
Wire
Ground 
Screw
* If screws are not tightened securely, it can result in 
electrical spark and severe personal injury or death.
Replace the access cover on the  back of the range. To 
replace  the wire cover, insert  the two tabs into the 
openings located below the opening and tighten the 
three screws.
Access cover