ELECTRICAL CONNECTIONS
3-WIRE CONNECTION WITH 
A POWER SUPPLY CORD
•  The middle (neutral or ground) wire, which 
is white, of a 3 wire power cord or  a 3 wire 
conduit has to  be connected to  the middle 
post of the main terminal block. The remaining 
two wires of the power cord or conduit have to 
be connected to the outside posts of the main 
terminal connection block.
-   Failure to do so can result in electrical shock, 
severe personal injury or death.
 WARNING
Install the power cord as follows:
For power cord installations, Hook  the strain relief  over 
the power cord hole (1
3
/
8
”) located below the rear of 
oven. Insert the power cord through the strain relief and 
tighten it. (Refer to Figure 7.)
DO NOT install the power cord without a strain relief.
1. Remove the lower 3 screws from the terminal block 
and retain them. (Refer to Figure 8.)
2. Insert the 3 screws through each power cord terminal 
ring and into the lower terminals of the terminal block. 
Make sure that the center (neutral) wire, which is 
white, is connected to the center lower position of the 
terminal block.
3.  Tighten 3 screws securely into the terminal block. Do 
not remove the ground strap connections.
4. Refer to page 13
Cord strain relief
Power cord
Conduit
connection
plate
Separate Strain Relief 
before installation
Assemble the strain relief 
to the 1
 3
/
8
” opening in 
Conduit connection plate
FIGURE 7
3-wire connection
Terminal 
block
Conduit
connection plate
Black White Red
FIGURE 8
* If screws are not tightened securely, it can result in 
electrical spark and severe personal injury or death.