http://us.lgservice.com IORO INSTALLATION INSTRUCTIONS PLEASE READ AND SAVE THESE INSTALLATION INSTRUCTIONS. P/NO.
YOUR SAFETY FIRST BEFORE YOU START • Proper installation is the installer's responsibility! - Read the entire manual before you begin. - The Model number label is located on the front of oven, behind door. See Figure - Mounting plate is located on back side of microwave oven. See Figure 2. BE SURE TO READ THE FOLLOWING SAFETY 1. iNSTRUCTiONS: Mounting Plate Model Number Plate Figure 1 Figure 2 WARNING For Your Safety = You will need TWO people to install this oven.
YOUR SAFETY FIRST • THIS APPLIANCE MUST BE GROUNDED! If there is an electrical short circuit, grounding reduces the risk of electrical shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug. • Place the plug into a properly installed and grounded outlet. See Figure 3. • Do not use an extension cord. PROPERLY POLARIZED AND • Keep the power cord dry and do not pinch or crush it.
YOUR SAFETY FIRST • MAKE SURE YOU HAVE ENOUGH SPACE AND SUPPORT. - Mount the oven against a flat, vertical wall, so that it is supported by the wall. The wall should be constructed of minimum 2" x 4" wood studding and 3/8" thick drywall or plaster/lath. - ATTACH AT LEAST ONE of the two lag screws supporting the oven to a vertical, 2" x 4" wall stud. - DO NOT mount the microwave oven to an island or peninsula cabinet. - BE SURE the upper cabinet and rear wall structures are able to support 150 Ibs.
PARTS, TOOLS, MATERIALS THE FOLLOWING PARTS ARE SUPPLIED WITH THE OVEN: NOTE: Depending on your ventilation requirements, you may not use all of these parts. Damper/duct connector (for roof venting or wall venting installation) Not Actual Size (2 pieces must be assembled as shown) One power cord clamp and One dark-colored mounting screw_ (to hold the power cord) Actual Size 1 | ....................
PARTS, TOOLS, MATERIALS You will need the following tools and materials for the installation: Carton or other heavy material for covering the counter top.
STEP 1: PREPARE CONNECTIONS THE ELECTRICAL WARNING AVOID ELECTRICAL SHOCKt THiS APPLIANCE MUST BE GROUNDED! 1. Locate the grounded electric outlet for this oven in the cabinet above the oven, as shown in Figure 5. Upper NOTE: The outlet should be on a circuit dedicated to the microwave oven (120V, 60 Hz., AC only) with a 15 or 20A fused electrical supply. i net IMPORTANT: If you do not have the proper wall outlet, you MUST have one installed by a qualified electrician. 2.
STEP 2: PREPARE THE VENTING SYSTEM NOTE: The ductwork you need for outside ventilation is not included with your oven. The standard ductwork fittings and length are shown in Figure 10, page 9. WARNING THIS OVEN MUST BE PROPERLY VENTED! You may vent your oven in one of three ways. Do NOT vent into a wall cavity, an attic, or an unused area. • Roof-venting If your oven is located on an outside wall near the roof, as in Figures 7 (3 1/4" x 10" duct) and Figure 9.
Standard Fittings NOTE: If the existing duct is round, you must use a rectangular-to-round adapter, with a rectangular 3" extension duct installed between the damper assembly and the adapter to prevent the exhaust damper's sticking. Duct Length The total length of the duct system, including straight duct, elbows, transitions, and wall or roof caps must not exceed the equivalent of 140 feet. For best performance, do not use more than three 90 degree elbows, and keep length as short as possible.
STEP 3: PREPARE BLOWER THE VENTING WARNING + To avoid risk of property damage, unplug the microwave source by removing fuse or throwing circuit breaker. +To avoid risk of personal injury, wear protective gloves oven or disconnect when handling power at mounting plate. DO NOT PULL OR STRETCH THE BLOWER WIRING! Pulling and stretching the blower wiring could result in electrical shock. • Your microwave oven is shipped with the blower assembled for room venting.
3.Reassemble theblower wire.SeeFigure 14. 4.Rotate theunitsothattheexhaust portsfacetherearofthecabinet. SeeFigure 16.Whenyouinsertblower unit, blower wiremustbelikefigure15. 5.Place blower unitbackintocabinet. Check thattheexhaust portsfacetowards therearofthecabinet. SeeFigure 16. 6.Reattach theblower platetocabinet sotheexhaust portsandblower plateopening arealigned. Attach withone blower unitmounting screw andthenoneortwoblower platemounting screw. SeeFigure 17.
STEP 4: PREPARE CABINET THE WALL & UPPER WARNING To avoid personal injury or property oven if you cannot find a wall stud, Measure And Tack/Tape damage, do not attempt to install this microwave Up The Templates 1. Using a plumb line and measuring tape, find and mark the vertical center line on the back wall, as in Figure 23. 0 2. Find and mark one or two points where the studs are on the wall. Then measure and mark the stud locations.
WARNING To avoid risk of personal o Note where • Locate electrical and disconnect installing injury, electrical outlets shock or death: and electrical wires power to any electrical are before circuits you drill into the wall. that could be affected by this oven. WARNING To avoid risk of personal injury, electrical shock or death, cover supply cord hole with the power supply cord bushing. the edge of the power Drill The Holes In The Wall And Upper Cabinet. 1. Drill holes on the circles.
STEP 5: INSTALL THE MOUNTING The Oven Must Be Connected To At Least One 3/16 Hole on Studs 5/8 Hole on Dry wall Only Wall Stud. 1. Draw a vertical line on the wall at the center of the space. Use the mounting plate as the template for wall. Place the mounting plate on the wall, making that the tabs are against the bottom of the cabinet. the notch and center line on the mounting plate to center line on the wall.
For Wall-Vented • Make the box cutout for the rear wall duct. II Use the wall template to determine the location and size of the box cutout for the rear wall duct. • Attach the exhaust adapter to the rear plate. See Figure 30. Push in securely until it is past the top locking tabs and in the lower locking tabs. Take care to assure the damper hinge is installed so that it is at the top and that the damper swings freely.
STEP 6: ATTACH THE OVEN TO THE WALL WARNING To avoid risk of personal injury or property install this microwave oven. 1. Carefully lift microwave oven and hang it on support tabs (See Figure 27) at the bottom of the mounting plate. Reaching through upper cabinet, thread power supply cord through the power supply cord hole in the bottom of the upper cabinet. See Figure 31. damage, use will need two people to power cord hole \ 2.
STEP 6: ATTACH THE OVEN TO THE WALL 5. Roof venting installation: See Figure 33. Install ductwork through the vent opening in the upper cabinet. Complete the venting system through the roof according to the method needed. See "Prepare The Venting System" STEP 2. Use caulking gun to seal the exterior roof opening around the exhaust cap. See Figure 7 on page 8. 6. Use the power supply cord clamp to bundle the power supply cord.