Installation Manual
Installation Manual 23
Installation
ENGLISH
Wall
Side
Wall
Side
Wall
Side
Wall
Side
<Connecting order>
<Separating order>
3. Please fix remote controller upper part into the
mounting plate attached to the surface of the
wall, as the picture on the right, and then,
connect with mounting plate by pressing lower
part.
- Please securely connect the remote controller to the
mounting plate.
- Before assembly with the mounting plate, arrange the Cable
not to interfere with circuit parts.
The remote controller can be separated from
the mounting plate by inserting a screw driver
into the slots located at the base of the
controller.
- There are two slots for separating the controller from the
mounting plate. Please individually separate one at a time.
- Please be careful not to damage the inside
components when separating.
4. Please connect indoor unit and remote controller using connection cable.
5. Please use extension cable if the distance between wired remote controller and
indoor unit is more than 10 m(32.8 ft).
Terminal Block
Indoor
RDYL BK
WIRED REMOTE
CONTROLLER
12 V Red
Signal Yellow
GND Black
CAUTION
When installing the wired remote controller, do not bury it in the wall.
(It can cause damage in the temperature sensor.)
Do not install the cable to be 50 m(164 ft) or above.
(It can cause communication error.)
• When installing the extension cable, check the connecting direction of the connector of the remote
controller side and the product side for correct installation.
• If you install the extension cable in the opposite direction, the connector will not be connected.
• Specification of extension cable: 2547 1007 22# 2 core 3 shield 5 or above.
!