MPS Variable Multi Split SYSTEM Free Joint, 50Hz, R410A LM50 2004-E1
General Description Thank you very much for your special patronage of LG air-conditioners. A high-grade, high-quality, advanced individual air-conditioning system that is able to respond to expanding, more sophisticated housing environment needs. LG Electronics Inc., which has been a top air conditioner maker for the three consecutive years, has developed "MPS(Multi Power System) Variable Multi Split" system that can efficiently control air-conditioning in a better way.
2 MPS Variable Multi Split System(50Hz, R410A)
LG Airconditioners Product Data TABLE OF CONTENTS Table of contents Page Part 1 Features...............................................................................................7 Part 2 MPS Variable Multi-Split system (R410A).......................................
4 MPS Variable Multi Split System(50Hz, R410A)
Part 1 Features 2004 Product Data 5
Features & Benefit MPS(Multi Power System) Variable Control : (Except A2UC146FA0,A2UH146FA0) Big Energy Saving with MPS Variable Control • Basic Principle of MPS Variable Control MPS control provides comfortable and convenient environment as there are two compressors with 60&40% load sharing with on compressor of small capacity always working to maintain the set temperature conditions & meanwhile other compressor is at rest if the load is low whereas in conventional system the only compressor is working wi
Features & Benefit Air Purifying System - It not only removes microscopic contaminants & dust, but it also removes house mites, pollen, and pet fur to help prevent allergic diseases like asthma.It provides odor free, dust free and allergy free air. (ppm) 500 Normal Filter 400 + + + + 300 + + + + 200 + + + + + + + + 100 Nano Filter • Effect of carbon Nano Ball 0 30 60 90(Min) Deodorizing efficieny: 8~10times compared to conventional carbon filter.
Features & Benefit Ultra-Slim design(Depth 129mm) 129 mm Thinnest Turbo Fan 3-Dimensional Cooling System New Cube 3-Dimension cooling system of ART COOL has Indirect Cooling mode for sleep operation. Being in sleep operation, cool air is discharged only right/left side! Indirect cooling ensures you nice sleep.
Features & Benefit Environment Friendly Refrigerant : - LG Air conditioners uses environment friendly refrigerant. Which don't do any harm to the environment. Jet Cool: - In this mode very quick and fast cooling is done. The unit will continue to supply high velocity air for 30 minutes, untill the room temperature reaches 18°C. After 30 minutes, unit will supply air at the set fan speed whether indoor temperature has reached 18°C or not.
10 MPS Variable Multi Split System(50Hz, R410A)
Part 2 MPS Variable Multi-Split System R410A, Cooling Only/Heat Pump AMNC076LQL0 AMNC096AP*1 AMNC096LQL0 AMNC126AP*1 AMNC126LRL0 A4UC306FA0 AMNC246LTL0 AMNH076LQL0 AMNH096AP*1 AMNH096LQL0 AMNH126AP*1 AMNH186LTL0 AMNH246LTL0 A2UC186FA0 A3UC216FA0 AMNC186LTL0 AMNH126LRL0 A2UC146FA0 A2UH146FA0 A2UH186FA0 A3UH216FA0 A4UH306FA0 1. Power Supply .................................................................................................................12 2. Model Number Nomenclature ..........
1. Power Supply Type Cooling Only Heat Pump Outdoor Unit Power Supply A2UC146FA0 A2UC186FA0 A3UC216FA0 A4UC306FA0 A2UH146FA0 A2UH186FA0 A3UH216FA0 A4UH306FA0 1Ø, 220~240V, 50Hz Note : Power Supply Intake ; Outdoor Unit Only External wiring procedure - The power supply is needed only to the outdoor unit. The power supply to the indoor unit Is conducted through the transmission wiring. Therefore, the power supply can be given at just one place.
2. Model Number Nomenclature 2.1 Indoor Units AMN H 07 6 L Q L 0 Serial Number Combination of Functions L : Nano Plasma ART COOL Type Front Panel Color B : Blue, D : Wood, M : Metal Chassis Name Indoor Unit Type L : Wall Mounted A : ART COOL Electrical Ratings 6: 1ø, 220~240V, 50Hz Nominal Cooling Capacity in Btu/h Ex) 7,000 Btu/h ➞ ‘07’ , 18,000 Btu/h ➞ ‘18’ Model Type C: Cooling Only H: Heat Pump Multi Split System Indoor Unit 2.
3. Outline of System The system has number of indoor units attached to an outdoor unit which saves energy while in operation. This system can be installed in small space and cooling can be controlled in each room individually. 3.1 Example of System [A4UH306FA0] 3.2 Combination of Indoor and Outdoor Unit Indoor Units Outdoor Unit A2UC146FA0 A2UC186FA0 A3UC216FA0 A4UC306FA0 A2UH146FA0 A2UH186FA0 A3UH216FA0 A4UH306FA0 Capacity Model Type Wall Mounted ART COOL 14 Index kW Btu/h 7 2.1 9 No.
3. Outline of System 3.
4. List of Functions Model Features Airflow Direction Control(Left & Right) Airflow Direction Control(Up & Down) Airflow Outlet Airflow Steps(Fan / Cool / Heat) Auto Changeover(Operation) Auto Cleaning Auto Restart Operation Central Control CHAOS Wind(Auto Wind) Child Lock Function Cooling & Heating Fan Operation Deice Control Deodorizing Filter Drain Pump E.S.
5. Specifications 5.1 Indoor Units Cooling Only Indoor Unit Type Wall Mounted Model Nominal Cooling Capacity ★ Nominal Heating Capacity ★ Air Circulation H/M/L Setting temperature range Fan motor Output Model No. of Poles Input Running Current Capacitor Fan Type No. Used / Diameter Fan RPM Cooling(H/M/L) Heating(H/M/L) Noise Level(Sound Press,1m) H/M/L Temperature controller Coil Tube Size (OD) Fins per inch No.
5. Specifications Heat Pump Indoor Unit Type Wall Mounted Model Nominal Cooling Capacity ★ Nominal Heating Capacity ★ Air Circulation H/M/L Setting temperature range Fan motor Output Model No. of Poles Input Running Current Capacitor Fan Type No. Used / Diameter Fan RPM Cooling(H/M/L) Heating(H/M/L) Noise Level(Sound Press,1m) H/M/L Temperature controller Coil Tube Size (OD) Fins per inch No.
5. Specifications 5.2 Outdoor Units Cooling Only A2UC146FA0 Model Cooling Capacity ★ Heating Capacity ★ Input ★ Running Current ★ Starting Current Power Supply Power Factor Compressor A Compressor B Refrigerant Coil Fan Motor Fan Cooling/Heating Cooling/Heating Cooling/Heating Locked Rotor Amp. Type Quantity Model Maker Capacity Motor Type Motor Input Oil Type Oil Charge O.L.P Type(model name) Locked Rotor Amp. Type Quantity Model Maker Capacity Motor Type Motor Input Oil Type Oil Charge O.L.
5. Specifications Heat Pump A2UH146FA0 Model Cooling Capacity ★ Heating Capacity ★ Input ★ Running Current ★ Starting Current Power Supply Power Factor Compressor A Compressor B Refrigerant Coil Fan Motor Fan Cooling/Heating Cooling/Heating Cooling/Heating Locked Rotor Amp. Type Quantity Model Maker Capacity Motor Type Motor Input Oil Type Oil Charge O.L.P Type(model name) Locked Rotor Amp. Type Quantity Model Maker Capacity Motor Type Motor Input Oil Type Oil Charge O.L.
6. Combination Table 6.1 Cooling Only 6.1.1 A2UC146FA0 Cooling Combination(k Btu) Operation 1 UNIT 2 UNIT A B C D 7 7 7 - - Total Unit-A 7 14 9000 7500 Cooling Capacity (Btu/h) Unit-B Unit-C Unit-D Total 7500 - - 7000 15000 Input (W) 1300 1400 Current EER (A) (Btu/h.W) 6.1 6.7 6.9 10.7 6.1.
6. Combination Table 6.1.
6. Combination Table 6.2 Heat Pump 6.2.1 A2UH146FA0 Cooling Operation 1 UNIT 2 UNIT Cooling Combination(k Btu) A B C D 7 7 7 - - Total Unit-A 7 14 9400 7200 Capacity (Btu/h) Unit-B Unit-C Unit-D 7200 - - Total Input (W) 9400 14400 1350 1450 Current EER (A) (Btu/h.W) 6.1 6.6 7.0 9.
6. Combination Table 6.2.
6. Combination Table 6.2.
6.
7. Dimensional Drawings 7.1 Indoor Units AMNC-LQ/LR/LT, AMNH-LQ/LR/LT H More than 5cm More than 5cm D W More than 5cm More than 2.3m Installation plate C B D Installation plate Ø70mm Left rear piping A Note: 1. Pipe Specification(mm) Model Liquid Gas 7, 9, 12k Ø 6.35 Ø 9.52 18, 24k Ø 6.35 Ø 12.
7. Dimensional Drawings AMNC-AP, AMNH-AP Hanger Hole W D H Fix Hole Pipe Hole (Unit: mm) Note: 1. Pipe Specification(mm) More than 10cm Model Liquid Gas 9, 12k Ø 6.35 Ø 9.
7. Dimensional Drawings 7.2 Outdoor Units A2UC146FA0, A2UH146FA0 L5 L1 L10 L11 L12 L13 H L4 L3 D L2 W L7 L6 L8 Gas side 3-way valve Liquid side 2-way valve L9 Model A2UC146FA0, A2UH146FA0 Dimensions W mm 801 H mm 555 D mm 262 L1 mm 339 L2 mm 300 L3 mm 37 L4 mm 543.6 L5 mm 11.4 L6 mm 591 L7 mm 105 L8 mm 105 L9 mm 72.5 L10 mm 74.
7. Dimensional Drawings A2UC186FA0, A2UH186FA0 L2 D L1 W L9 L10 L10L10 L3 H L4 Gas side 3-Way valve L6 L5 L7 Liquid side 2-Way valve L8 Model A2UC186FA0, A2UH186FA0 Dimensions 30 W mm 870 H mm 655 D mm 320 L1 mm 370 L2 mm 25 L3 mm 630 L4 mm 25 L5 mm 546 L6 mm 160 L7 mm 160 L8 mm 64 L9 mm 76.
7. Dimensional Drawings A3UC216FA0, A3UH216FA0 L4 H L3 L9 L10 L10 L10 L10 L10 L2 D L1 W L6 L5 L7 Gas side 3-way valve Liquid side 2-way valve L8 Model A3UC216FA0, A3UH216FA0 Dimensions W mm 870 H mm 655 D mm 320 L1 mm 370 L2 mm 25 L3 mm 630 L4 mm 25 L5 mm 546 L6 mm 160 L7 mm 160 L8 mm 64 L9 mm 76.
7. Dimensional Drawings A4UC306FA0, A4UH306FA0 320 340 360 4-holes for anchor bolts 1030 3 160 Number 32 550 870 76.5 50 50 50 50 50 50 1060 4 2 1 160 Name 64 320 Descripition 1 Liquid side service valve(mm) Ø6.35 2 Gas side service valve(mm) Ø9.
8. Wiring Diagrams 8.
8. Wiring Diagrams CN-ACDC2 ZNR CN-ACDC1 FAN MOTOR CN-MOTOR1 WH BK YL RD DC PWB ASM CN-GND1 AC PWB ASM 1(L) 2(N) CN-POWER RD BL GN/YL BR Z 3 FUSE 250V 3.
8. Wiring Diagrams 8.2 Outdoor Unit A2UC146FA0 OUTDOOR WIRING DIAGRAM BK CN-COMP 1(L) 2(N) F C CM BL MAIN PCB ASSY BR BL BK BK (BK) BK BL BK A S/V BK B S/V BK B/P S/V (BL) BL RD (RD) BK CN-POWER (WH) B-UNIT T/B1 RD YL RD FUSE 250V T3.
8. Wiring Diagrams A2UC186FA0 OUTDOOR WIRING DIAGRAM BK OR YL TB1 TM LEV B BL Co F BK CN-LEV2 CN-LEV1 (WH) (BL) 2(N) BR BK H RD RD OR CN-COMP (RD) BK Co TO INDOOR UNIT-B COMP-A C C S COMP-B R MAIN PWB ASSY 2(N) BK CN-COM (WH) 1(L) GN/YL MAIN POWER YL BR YL 3 R S BL OLP RD BL C OLP BL 3 GN/YL FMo (WH) LEV A 1(L) TO INDOOR UNIT-A BK BL OR BR YL CN-FAN1 (WH) BL BR 1(L) FUSE T3.
8. Wiring Diagrams A3UC216FA0 OUTDOOR WIRING DIAGRAM BK OR YL GN/YL TB1 GN/YL TM LEV C BL LEV B LEV A BK BL OR BR YL FMo (WH) Co F 1(L) TO INDOOR UNIT-A BK CN-LEV3 CN-LEV2 CN-LEV1 (YL) (BL) (WH) 2(N) C BK H RD OLP BL BL R S COMP-A C BR 3 BL CN-COMP (RD) BK Co YL BR YL C S COMP-B R RD MAIN PWB ASSY 2(N) 1(L) TO INDOOR UNIT-C BR CN-FAN1 (WH) BL GN/YL BK CN-COM (WH) 3 GN/YL POWER SUPPLY RD OR 3 TO INDOOR UNIT-B OLP RD FUSE T3.
8. Wiring Diagrams A4UC306FA0 GN/YL OUTDOOR WIRING DIAGRAM GN/YL BK BL OR BR YL BL TO INDOOR UNIT-A TB1 TM LEV D BL LEV C LEV B BK BL OR BR YL LEV A FMo1 (WH) Co F 3 TO INDOOR UNIT-B 2(N) RD 3 YL BR BK FUSE T3.
8. Wiring Diagrams A2UH146FA0 OUTDOOR WIRING DIAGRAM BK CN-COMP 1(L) 2(N) BK BR C CM BL BK (WH) CN-COM BL BK BL BK BL CN-TH1 WH WH (WH) (RD) BK (BK) BK BK A S/V BK B S/V BK B/P S/V BK 4WV (BL) BL RD (RD) CN-POWER (WH) BK T/B1 RD YL RD FUSE 250V T3.
8. Wiring Diagrams A2UH186FA0 OUTDOOR WIRING DIAGRAM BK OR YL TB1 TM LEV B BL Co F BK CN-LEV2 CN-LEV1 (BL) (WH) 2(N) BL 3 RD C BK H RD OLP BK BL CN-COMP (RD) BR OLP TB2 YL 3 TO INDOOR UNIT-B COMP-A RD YL Co BK BR C C S COMP-B R MAIN PWB ASSY 2(N) BK BK CN-COM (WH) 1(L) GN/YL MAIN POWER R S BL OR GN/YL FMo (WH) LEV A 1(L) TO INDOOR UNIT-A BK BL OR BR YL CN-FAN1 (WH) BL BR 1(L) FUSE T3.
8. Wiring Diagrams A3UH216FA0 OUTDOOR WIRING DIAGRAM GN/YL BK OR YL TB1 GN/YL TM LEV C BL LEV B LEV A BK BL OR BR YL FMo (WH) Co F 1(L) TO INDOOR UNIT-A BK CN-LEV3 CN-LEV2 CN-LEV1 (YL) (BL) (WH) 2(N) C BK H RD OLP BL BL R S COMP-A C BR BK 3 RD BL CN-COMP (RD) TB2 YL YL Co BR BK C S COMP-B R RD 2(N) MAIN PWB ASSY 1(L) TO INDOOR UNIT-C BK BR CN-FAN1 (WH) BL GN/YL BK CN-COM (WH) 3 GN/YL POWER SUPPLY RD OR 3 TO INDOOR UNIT-B OLP FUSE T3.
8. Wiring Diagrams A4UH306FA0 GN/YL OUTDOOR WIRING DIAGRAM GN/YL TB1 TM LEV D BL LEV C LEV B BK BL OR BR YL BK BL OR BR YL BL TO INDOOR UNIT-A LEV A FMo1 (WH) Co F 3 TO INDOOR UNIT-B 2(N) RD 3 YL BR BK CN-FAN2 (WH) BR 3 FUSE T3.
9. Piping Diagrams 9.1 Indoor Unit 9.1.1 Cooling Only Wall Mounted Heat Exchanger :Cooling Refrigerant pipe connection port diameter C.F.F [unit:mm(inch)] Model AMNC076LQL0 AMNC096LQL0 AMNC126LRL0 AMNC186LTL0 AMNC246LTL0 lndoor unit Gas Liquid Ø9.52(3/8) Ø6.35(1/4) Ø12.7(1/2) : Thermistor ART COOL Heat Exchanger Turbo Fan :Cooling Refrigerant pipe connection port diameter [unit:mm(inch)] lndoor unit Model AMNC096AP*1 AMNC126AP*1 Gas Liquid Ø9.52(3/8) Ø6.
9. Piping Diagrams 9.1.2 Heat Pump Wall Mounted Heat Exchanger :Cooling :Heating Refrigerant pipe connection port diameter C.F.F [unit:mm(inch)] lndoor unit Model AMNH076LQL0 AMNH096LQL0 AMNH126LRL0 AMNH186LTL0 AMNH246LTL0 Gas Liquid Ø9.52(3/8) Ø6.35(1/4) Ø12.
9. Piping Diagrams 9.2 Outdoor Unit 9.2.
9.
9. Piping Diagrams 9.2.
9.
10. Capacity Table Cooling Only 10.1 A2UC146FA0 [Cooling Capacity] Combination Capacity Index (kBtu/h) 7 7+7 Outdoor Air Temp.: °CDB 21 24 29 35 41 46 21 24 29 35 41 46 14 TC kW 16 PI kW 2.52 2.48 2.39 2.28 2.16 2.02 4.19 4.13 3.98 3.80 3.60 3.36 0.89 0.98 1.12 1.24 1.33 1.40 0.96 1.05 1.21 1.33 1.43 1.51 TC kW PI kW 2.69 2.66 2.56 2.45 2.31 2.16 4.49 4.43 4.27 4.08 3.86 3.60 0.90 0.99 1.14 1.26 1.35 1.43 0.97 1.07 1.23 1.36 1.45 1.54 Indoor Air Temp.: °CWB 18 19 TC PI TC PI kW kW kW kW 2.
10. Capacity Table Cooling Only 10.3 A3UC216FA0 [Cooling Capacity] Combination Capacity Index (kBtu/h) 7 9 12(ART COOL) 12 7+7 7+9 9+9 7+12(ART COOL) 7+12 9+12 7+7+7 7+7+9 Outdoor Air Temp.: °CDB 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 14 TC kW 2.24 2.20 2.12 2.03 1.92 1.79 2.66 2.62 2.52 2.41 2.28 2.13 3.07 3.03 2.
10. Capacity Table Cooling Only 10.4 A4UC306FA0 [Cooling Capacity] Combination Capacity Index (kBtu/h) 7 9 12 18 24 7+7 7+9 7+12 7+18 7+24 9+9 9+12 Outdoor Air Temp.: °CDB 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 14 TC kW 2.52 2.48 2.39 2.28 2.16 2.02 2.80 2.76 2.66 2.54 2.40 2.24 3.35 3.31 3.19 3.04 2.88 2.69 5.03 4.
10. Capacity Table Combination Capacity Index (kBtu/h) 9+18 9+24 12+12 12+18 7+7+7 7+7+9 7+7+12 7+7+18 7+9+9 7+9+12 7+12+12 9+9+9 52 Outdoor Air Temp.: °CDB 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 14 TC kW 7.83 7.72 7.44 7.10 6.72 6.28 8.39 8.27 7.97 7.61 7.20 6.73 7.27 7.16 6.90 6.59 6.24 5.83 8.39 8.27 7.97 7.61 7.
10. Capacity Table Combination Capacity Index (kBtu/h) 9+9+12 9+12+12 7+7+7+7 7+7+7+9 7+7+7+12 7+7+9+9 Outdoor Air Temp.: °CDB 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 Cooling Only 14 TC kW 8.39 8.27 7.97 7.61 7.20 6.73 8.39 8.27 7.97 7.61 7.20 6.73 8.39 8.27 7.97 7.61 7.20 6.73 8.39 8.27 7.97 7.61 7.20 6.73 8.39 8.27 7.97 7.61 7.20 6.73 8.39 8.27 7.97 7.61 7.20 6.73 16 PI kW 2.22 2.44 2.80 3.10 3.32 3.51 2.22 2.44 2.80 3.10 3.
10. Capacity Table Heat Pump 10.5 A2UH146FA0 [Cooling Capacity] Combination Capacity Index (kBtu/h) 7 7+7 Outdoor Air Temp.: °CDB 21 24 29 35 41 46 21 24 29 35 41 46 14 TC kW 16 PI kW 2.63 2.59 2.50 2.38 2.26 2.11 4.03 3.97 3.82 3.65 3.46 3.23 0.92 1.01 1.16 1.29 1.38 1.46 0.99 1.09 1.25 1.38 1.48 1.56 TC kW PI kW 2.81 2.77 2.67 2.55 2.42 2.26 4.31 4.25 4.10 3.91 3.70 3.46 0.94 1.03 1.18 1.31 1.40 1.48 1.01 1.11 1.27 1.41 1.50 1.59 Notes: 1. Capacities are based on the following conditions.
10. Capacity Table Heat Pump 10.6 A2UH186FA0 [Cooling Capacity] Combination Capacity Index (kBtu/h) 7 9 12 7+7 7+9 9+9 7+12 Outdoor Air Temp.: °CDB 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 14 TC kW 1.96 1.93 1.86 1.78 1.68 1.57 2.66 2.62 2.52 2.41 2.28 2.13 3.07 3.03 2.92 2.79 2.64 2.47 3.91 3.86 3.72 3.55 3.36 3.14 4.47 4.41 4.25 4.06 3.84 3.59 5.03 4.96 4.78 4.57 4.32 4.04 5.03 4.96 4.78 4.57 4.32 4.
10. Capacity Table Heat Pump [Heating Capacity] Combination Capacity Index (kBtu/h) 7 9 12 7+7 7+9 9+9 7+12 Indoor Air Temp.: °CDB 16 18 20 22 24 16 18 20 22 24 16 18 20 22 24 16 18 20 22 24 16 18 20 22 24 16 18 20 22 24 16 18 20 22 24 -10 TC kW 1.78 1.72 1.67 1.61 1.56 2.08 2.01 1.95 1.88 1.82 2.39 2.32 2.25 2.17 2.09 3.05 2.95 2.86 2.76 2.66 3.48 3.37 3.27 3.15 3.05 3.92 3.79 3.68 3.55 3.43 3.92 3.79 3.68 3.55 3.43 -5 PI kW 0.95 0.98 1.01 1.04 1.08 0.91 0.94 0.97 1.00 1.04 0.87 0.90 0.93 0.
Heat Pump 10. Capacity Table 10.7 A3UH216FA0 [Cooling Capacity] Combination Capacity Index (kBtu/h) 7 9 12(ART COOL) 12 7+7 7+9 9+9 7+12(ART COOL) 7+12 9+12 7+7+7 7+7+9 Outdoor Air Temp.: °CDB 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 14 TC kW 2.24 2.20 2.12 2.03 1.92 1.79 2.66 2.62 2.52 2.41 2.28 2.13 3.07 3.03 2.92 2.
10. Capacity Table Heat Pump [Heating Capacity] Combination Capacity Index (kBtu/h) 7 9 12(ART COOL) 12 7+7 7+9 9+9 7+12(ART COOL) 7+12 9+12 7+7+7 7+7+9 Indoor Air Temp.: °CDB 16 18 20 22 24 16 18 20 22 24 16 18 20 22 24 16 18 20 22 24 16 18 20 22 24 16 18 20 22 24 16 18 20 22 24 16 18 20 22 24 16 18 20 22 24 16 18 20 22 24 16 18 20 22 24 16 18 20 22 24 -10 TC kW 1.78 1.72 1.67 1.61 1.56 2.07 2.00 1.94 1.87 1.81 2.39 2.32 2.25 2.17 2.09 2.61 2.53 2.45 2.37 2.28 3.64 3.53 3.42 3.30 3.18 3.
Heat Pump 10. Capacity Table 10.8 A4UH306FA0 [Cooling Capacity] Combination Capacity Index (kBtu/h) 7 9 12 18 24 7+7 7+9 7+12 7+18 7+24 9+9 9+12 Outdoor Air Temp.: °CDB 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 14 TC kW 2.52 2.48 2.39 2.28 2.16 2.02 2.80 2.76 2.66 2.54 2.40 2.24 3.35 3.31 3.19 3.04 2.88 2.69 5.03 4.96 4.
10. Capacity Table Combination Capacity Index (kBtu/h) 9+18 9+24 12+12 12+18 7+7+7 7+7+9 7+7+12 7+7+18 7+9+9 7+9+12 7+12+12 9+9+9 60 Outdoor Air Temp.: °CDB 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 14 TC kW 7.83 7.72 7.44 7.10 6.72 6.28 8.39 8.27 7.97 7.61 7.20 6.73 7.27 7.16 6.90 6.59 6.24 5.83 8.39 8.27 7.97 7.61 7.
10. Capacity Table Combination Capacity Index (kBtu/h) 9+9+12 9+12+12 7+7+7+7 7+7+7+9 7+7+7+12 7+7+9+9 Outdoor Air Temp.: °CDB 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 21 24 29 35 41 46 Heat Pump 14 TC kW 16 PI kW 8.39 8.27 7.97 7.61 7.20 6.73 8.39 8.27 7.97 7.61 7.20 6.73 8.39 8.27 7.97 7.61 7.20 6.73 8.39 8.27 7.97 7.61 7.20 6.73 8.39 8.27 7.97 7.61 7.20 6.73 8.39 8.27 7.97 7.61 7.20 6.73 2.22 2.44 2.80 3.10 3.32 3.51 2.22 2.44 2.80 3.10 3.32 3.
10. Capacity Table Combination Capacity Index (kBtu/h) 7+9 7+12 7+18 7+24 9+9 9+12 9+18 9+24 12+12 12+18 7+7+7 7+7+9 7+7+12 7+7+18 7+9+9 62 Indoor Air Temp.: °CDB "16 18 20 22 24 16 18 20 22 24 16 18 20 22 24 16 18 20 22 24 16 18 20 22 24 16 18 20 22 24 16 18 20 22 24 16 18 20 22 24 16 18 20 22 24 16 18 20 22 24 16 18 20 22 24 16 18 20 22 24 16 18 20 22 24 16 18 20 22 24 16 18 20 22 24 Heat Pump TC kW PI kW TC kW PI kW Outdoor Air Temp.: °CWB 0 6 TC PI TC PI kW kW kW kW "3.68 3.56 3.
10. Capacity Table Combination Capacity Index (kBtu/h) 7+9+12 7+12+12 9+9+9 9+9+12 9+12+12 7+7+7+7 7+7+7+9 7+7+7+12 7+7+9+9 Indoor Air Temp.: °CDB 16 18 20 22 24 16 18 20 22 24 16 18 20 22 24 16 18 20 22 24 16 18 20 22 24 16 18 20 22 24 16 18 20 22 24 16 18 20 22 24 16 18 20 22 24 Heat Pump -10 TC kW 6.29 6.09 5.91 5.70 5.50 6.51 6.30 6.12 5.90 5.69 6.53 6.32 6.13 5.91 5.71 6.53 6.32 6.13 5.91 5.71 6.53 6.32 6.13 5.91 5.71 6.49 6.28 6.10 5.88 5.68 6.53 6.32 6.13 5.91 5.71 6.61 6.40 6.21 5.99 5.
11. Operation Limits Inlet air temperature (Cooling) Range Outdoor air temperature °C D.B.(°F) Item 43(118.4) Standard operation 21(69.8) 15(59) 24(75.2) Inlet air temperature (Heating) Outdoor air temperature °C W.B.(°F) Indoor air temperature °C W.B.(°F) 18(64.4) Standard operation -7(14) 10(50) 24(75.2) Indoor air temperature °C D.B.(°F) Power source voltage Rating ±10% Voltage at starting Min.
12. Air Velocity and Temperature Distributions(Reference Data) 12.1 Wall Mounted Type 7k Btu/h Model Cooling Heating Discharge angle:45° Discharge angle:50° Air velocity [m/s] Air velocity [m/s] 2.7m 2.7m 2m 2m 0.5 1.5 1.5 1.0 1m 1m 1.0 0.5 5m 4m 3m 2m 0m 0m 1m Temperature [˚C] 5m 2.7m 4m 3m 2m 0m 0m 1m Temperature [˚C] 2.7m 2m 2m 21 18 20 4m 3m 33 30 1m 1m 27 22 24 5m 24 2m 0m 0m 1m 5m 4m 3m 2m 0m 0m 1m 12.
13. Sound Levels 13.1 Indoor Unit Wall Mounted Overall Notes: - Sound measured at 1m away from the center of the unit. - Data is valid at free field condition. - Data is valid at nominal operation condition. - Reference accoustic pressure 0dB=20µPa. - Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient) of particular room in which the equipment is installed. - The operating conditions are assumed to be standard(KS conditions). 1m 0.
13. Sound Levels ART COOL Overall Notes: - Sound measured at 1m away from the center of the unit. - Data is valid at free field condition - Data is valid at nominal operation condition - Reference accoustic pressure OdB = 20µPa - Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient) of particular room in which the equipment is installed. - The operating conditions are assumed to be standard(KS conditions) 1m 0.
13. Sound Levels 13.2 Outdoor Unit Overall Notes: - Sound measured at 1m away from the center of the unit. - Data is valid at free field condition. - Data is valid at nominal operation condition. - Reference accoustic pressure 0dB=20µPa. - Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient) of particular room in which the equipment is installed. - The operating conditions are assumed to be standard(KS conditions).
14. Installation 14.1 Piping Length & Refrigerant Charge The maximun allowable level and piping length [Outdoor Unit] It does not matter which unit is higher. Indoor Unit A B 7.5m C 7.5m D Model [Outdoor Unit] Standard Length Max piping length each indoor unit A, B, C, D A B C D Max total piping length A2UC/H146FA0 7.5m 15m 15m - - 30m(A+B) A2UC/H186FA0 7.5m 15m 15m - - 30m(A+B) A3UC/H216FA0 7.5m 15m 15m 15m - 45m(A+B+C) A4UC/H306FA0 7.
14. Installation 14.2 Select the best location 14.2.1 Indoor Unit Install the air conditioner in the location that satisfies the following conditions. Wall Mounted Type • There should not be any heat source or steam near the unit. • There should not be any obstacles to prevent the air circulation. Lower than 2.3m More than 5 cm More than 5 cm • There should be easy provision of condensate drain age.
14. Installation 14.2.2 Outdoor Unit • If an awning or canopy is built over the unit to prevent direct sunlight or rain exposure, make sure that heat radiation from the condenser is not restricted. • Ensure that the space around the back is more than 20~30cm and sides is more than 20~30cm. The front of the unit should have more than 70cm of space. • Do not place animals and plants in the path of the warm air.
14. Installation 14.4 Connecting Pipings and the cable to Outdoor unit 14.4.1 Connecting the pipings to the Outdoor unit 1. While installing pipes, you must use the connector. Indoor Units Gas A 18k, 24k 2. Align the center of the pipings and tighten the flare nut by hand Liquid B Ø9.52→Ø12.7 A B Not necessary Connector A B 3. Finally, tighten the flare nut with torque wrench until the wrench clicks.
14. Installation CAUTION: Provide a circuit breaker between power source and the unit as shown below. Main power source Circuit Breaker Use a circuit breaker or time delay fuse. Air Conditioner CAUTION: The power cord connected to the outdoor unit should be complied with the following specifications (Cable type approved by HAR or SAA). (mm2) Grade NORMAL CROSS SECTIONAL AREA Cable Type 18k 24k 30k 40k 2.5 2.5 3.5 5.5 GN /YL 20 mm H05RN-F H05RN-F H05RN-F H05RN-F ø7.
14. Installation CAUTION After the confirmation of the above conditions, prepare the wiring as follows. 1. Never fail to have an individual power circuit specifically for the air conditioner. For wiring, methed take guidance from the circuit diagram posted on the inside of control cover. 2. Firmly tighten the terminal screws to prevent them loosening. After tightening, pull the wires lightly to confirm that they do not move.
14. Installation 14.5 Drain Pipe Work ❑ Drain pipe gradient and support 1) - The drain pipe must be fitted at a gradient of at least 1/100. - The drain pipe should be as short as possible and free from airlocks. Indoor unit Gradient of at least 1 / 100 (1cm/ 1m) 2) Suspension bolts should be used to support long stretches of drain pipe in order to ensure that a gradient of 1/100 is maintained.
15. Function of Remote Controller 15.1 Wireless LCD Remote Controller 1 Signal transmitter 2 3 4 5 5 1 6 6 3 7 4 2 7 11 8 13 14 10 CANCEL ON OFF SET AUTO CLEAN 9 8 17 18 9 12 10 16 15 11 12 Flip-up door (opened) 13 Operation Mode 14 Cooling Operation Auto Operation 15 Healthy Dehumidification Operation 16 Heating Operation 17 • Cooling Model( ), Heat Pump Model( ) 18 76 START/STOP BUTTON Operation starts when this button is pressed and stops when the button is pressed again.
20 Yoido-dong, Youngdungpo-gu, Yoido P.O.Box 355 Seoul 150-721, Korea Phone: 3777-7969 Fax: 3777-5137/8 http://www.lge.com http://biz.lgservice.com P/No.: 3828A20428F For continual product development, LG reserves the right to change specifications without notice ©LG Electronics INC. Printed in Korea.