User guide
14
Installation
3
Installation
ALARM output connections
Connect the alarm device to the alarm output data port.
Alarm signal output at an event occurrence. You can set the
Alarm Output to the normal open or normal close mode.
1. Connect the adaptor cable to the Alarm Out Data
Terminal of the camera.
2. Connect the alarm device to the adaptor cable.
When connecting lines, check and connect the color
lines of the each device correctly. Refer to the below
tables for color line information.
Alarm Out connection
D
C
B
A
F
E
Alarm device
Alarm device
Alarm device
Alarm device
Alarm device
Adaptor Cable
Alarm Out Data Terminal
Alarm device
Alarm device
Alarm device
Adaptor cable
No Description
A
ALARM OUT [NO1]
B
ALARM OUT [COM1]
C
ALARM OUT [NC1]
D
NC
E
ALARM OUT [NO2]
F
ALARM OUT [COM2]
G
ALARM OUT [NC2]
H
NC
Alarm Out Data Terminal
Description Color
ALARM OUT [NO1] White Blue
ALARM OUT [COM1] Beige
ALARM OUT [NC1] Black
ALARM OUT [NO2] Brown
ALARM OUT [COM2] Red
ALARM OUT [NC2] Orange