User guide
Installation
19
3
Installation
Connecting power source
Connect a AC 24 V power source to the power input jack.
(Recommended power adaptor is AC 24 V/2 A or above.)
Protocol and baud rate settings
The camera has one 8-bit DIP switch blocks that determine
the protocol and baud rate of the data communication.
Settings are loaded when the camera boots up. Be sure to
turn the camera off, change the DIP switch settings, and
then power the camera back up to load the changes.
1. Turn off the camera.
2. Remove the dome cover.
3. Remove the camera assembly cover.
4. Set the DIP switches.
DIP switch locations
5. Assemble the dome cover and the camera assembly
cover in the reverse order.
6. Power up the camera to load the changes.
Baud Rate setting
ON
OFF
ON
DIP switch position
BAUD RATE
(BPS)
SW1 SW2 SW3 SW4
OFF OFF OFF OFF 9 600
OFF OFF OFF ON 2 400
OFF OFF ON OFF 4 800
OFF ON OFF OFF 19 200
ON OFF OFF OFF 38 400
ON ON ON ON OSD Set
Protocol setting
ON
ON
OFF
DIP switch position
Protocol
SW5 SW6 SW7 SW8
OFF OFF OFF OFF LG Multix
OFF ON OFF OFF Pelco C
OFF OFF OFF ON Pelco D
OFF OFF ON OFF Pelco P
ON ON ON ON OSD Set
If you are not using the controller with LG Multix
protocol, there may be some limitation of function
control.
,
Note