User guide

Installation
17
3
Installation
Alarm Out Data Terminal
Description Color
ALARM OUT [NO1] White Blue
ALARM OUT [COM1] Beige
ALARM OUT [NC1] Black
ALARM OUT [NO2] Brown
ALARM OUT [COM2] Red
ALARM OUT [NC2]
Orange
Connecting LKD1000 controller
For LCP2850I-AN/AP
1. Connect the RJ-45 Adaptor cable to the PORT A (RJ-45)
cable of the camera.
2. Connect the LKD1000 controller to the RJ-45 Adaptor
cable. (Refer to the manuals of the LKD1000 controller
for more details.)
LKD1000 connection
E
D
C
B
A
G
F
H
PORT A
TX-
TX+
RJ-45 Adapter cable
E
D
C
B
A
G
F
H
PORT A
RJ-45 Adapter cable
RS-485 device
RJ-45 Adaptor cable
PORT A
RJ-45 Adaptor cable
No Description Color
A
RS-485 + White
B
RS-485 - Orange
For LCP2850-AN/AP
1. Connect the Adaptor cable to the RS-485 Data
Communication of the camera.
2. Connect the LKD1000 controller to the Adaptor cable.
(Refer to the manuals of the LKD1000 controller for
more details.)
LKD1000 connection
B
A
B
A
TX-
TX+
RS-485 device
Adaptor cable
RS-485 Data
Communication
Adaptor cable
No Description
A
RS-485 +
B
RS-485 -
Connecting RS-485 device
Use the cable that is described below for RS-485 site
communication.
• Shielded, twisted pair cable
• Low impedance
• Wire gauge size is thicker than AWG #22 (0.33 mm
2
).