User guide
14
Installation
3
Installation
PORT A
Description Color
RS-485 + Red/White
RS-485 - Black/White
NC
ALARM IN COM Red
ALARM IN 1
White
ALARM IN 2
Light Green
ALARM IN 3 Yellow
ALARM IN 4 Pink
For LCP2850-AN/AP
1. Connect the Adaptor cable to the Alarm In Data
Terminal of the camera.
2. Connect the alarm device to the Adaptor cable.
When connecting lines, check and connect the color
lines of the each device correctly. Refer to the below
tables for color line information.
Do not connect one alarm sensor to the several
camera’s alarm input connector.
>
Caution
Alarm input connection
E
D
C
B
A
Alarm device
Alarm In Data Terminal
Alarm device
Alarm device
Alarm device
Adaptor Cable
Adaptor cable
No
Description
A
ALARM IN 1
B
ALARM IN 2
C
ALARM IN COM
D
ALARM IN 3
E
ALARM IN 4
Alarm In Data Terminal
Description Color
ALARM IN 1 Pink
ALARM IN 2 Gray