Owner’s Manual
Table Of Contents
- IMPORTANT SAFETY INSTRUCTIONS
- PRODUCT OVERVIEW
- INSTALLATION
- Before Installing
- Installing the Cooktop
- Electrical Connections
- Important Safety Instructions
- Providing the Electrical Connection
- Electrical Requirements
- Electrical Connection
- Where Local Codes Permit Connecting the Appliance-Grounding Conductor to the Neutral (White) Wire
- If Cooktop is Used in a New Branch Circuit Installation (1996 NEC), Mobile Home, Recreational Vehicle, or where Local Codes Do Not Permit Grounding to the Neutral (White) Wire
- Installing the Cooktop Unit
- Final Check
- Electrical Connections
- OPERATION
- MAINTENANCE
- TROUBLESHOOTING
- LIMITED WARRANTY
12 INSTALLATION
Preparing the Installation Location
Important Installation Information
• All electric cooktops run off a single phase, three-wire or four-wire cable, 240/208 volt, 60 hertz, AC-only
electrical supply with ground.
• Minimum distance between cooktop and overhead cabinetry is 30" (762 mm).
• Make sure the cabinets and wall coverings around the cooktop can withstand the temperatures (up to 93
℃ [200 ℉]) generated by the cooktop.
Dimensions and Clearances
a Do not obstruct these areas.
b 4″ X 8″ (102 mm x 203 mm) opening to route armored cable if panel is present.
c Approximate location of junction box
- Dimension/Clearance LCE3010SBE LCE3610SBE
A Width of upper plate 30 3/4" (781 mm) 36 5/8" (930 mm)
B Depth of upper plate 21 7/16" (544.5
mm)
21 15/16" (557 mm)
C Height of cooktop base 3 3/4" (95 mm)
D Width of cooktop base 28 13/16" (732 mm) 33 27/32" (860 mm)
E Depth of cooktop base 19 5/8" (498 mm) 19 25/32" (502 mm)
F Width of cutout 29 3/8" (746 mm) 34 9/16" (878 mm)
G Depth of cutout 20 1/4" (515 mm) 20 3/8" (517 mm)