Spec Sheet
Date:
JobName/Location:
PONo.:
Architect:
Engr:
GC:
Rep:
For:
File
A
pp
roval
Mech:
Resubmit
Other
Tag#:
(Company)
(ProjectManager)
Performance:
Cooling(Min‐Rated‐Max,Btu/h)
Heating(Min‐Rated‐Max,Btu/h)
SEER
EER
IDUAirCirculation(CFMH/M/L)
FanSpeeds(Fan/Cooling/Heating)
4/5/4
Dehumidification(pts/hr)
Electrical:
CoolingPowerInput(kW)
HeatingPowerInput(kW)
Features:
O
p
eratin
g
Ran
g
e:
OutdoorUnit:
Cooling(°FDB)
Heating(°FWB)
-4 ‐ 64
IndoorUnit:
Heating(°FDB)
59‐81
UnitData:
RefrigerantType
R410A
RefrigerantControl
EEV
Piping:
RefrigerantCharge(lbs)
IDUSoundPressure(H/M/L)±3dB(A)⁴
ODUSoundPressureMax(Cool/Heat)±3dB(A)⁴
ODUNetUnitWeight(lbs)
ODUShippingWeight(lbs)
IDUNetUnitWeight(lbs)
IDUShippingWeight(lbs)
GrilleWeight(lbs)
GrilleShippingWeight(lbs)
Notes:
1.Acceptableoperangvoltage:187V‐253V.
2.Pipinglengthsareequivalent.
3.Mustcomplywithapplicablecodesforfireisolaondampers.
4.SoundpressurelevelsaretestedinananechoicchamberunderISOStandard1996.
5.Allcommunicaon/powercabletobeminimum18Americanwiregauge(AWG),4‐
conductor,stranded,shieldedandmustcomplywithapplicablelocalandnationalcode.
6.Thisunitcomeswithadryheliumcharge.
7.Nominaldataisrated0abovesealevel,with25ofrefrigerantlineanda0level
differencebetweenoutdoorandindoorunits.
8.Powerwiringcablesizemustcomplywiththeapplicablelocalandnaonalcode.
9.MustfollowinstallaoninstruconsintheapplicableLGinstallaonmanual.
10.Multi-compatible IDUs include socket adapters for refrigerant pipe connection with
Single Zone systems.
Fan:
ODUType
Propeller
Cooling(°FWB)
57‐77
HSPF
• Autorestart
• Autochangeover
•Ultra‐quietturbofan
•Optional Wi-Fi control
Page1of3
Forcontinualproductdevelopment,LGreservestherighttochangespecificationswithoutnotice.
©LGElectronicsU.S.A.,Inc.,EnglewoodCliffs,NJ.Allrightsreserved.“LGLife’sGood”isaregistered trademarkofLGCorp./www.lghvac.com
SEER‐SeasonalEnergyEfficiencyRatioEER‐EnergyEfficiencyRatio
MOP‐MaximumOvercurrentProtection MCA‐MinimumCircuitAmpacity
Cooling:
Heating:
HSPF‐HeatingSeasonalPerformanceFactor
PowerSupply(V¹/Hz/Ø)
208‐230/60/1
MOP(A)
MCA(A)
CoolingRatedAmps(A)
HeatingRatedAmps(A)
Compressor(A)
Fan(IDU+ODU) (A)
• Inverter(Variablespeedcompressor)
• Internalcondensatepump
•SwirlWind
•
JetCool
•I
IDU compatible with Multi F ODUs
RequiredAccessories(soldseparately):
IDUFanType
Turbo
FanQuantity(ODU+IDU)
(1+1)
Motor/Drive BrushlessDigitallyControlled/Direct
ODUAirCirculation(CFM)
Liquid(in,OD, Connection Size/Pipe Size)
Vapor(in,OD, Connection Size/Pipe Size)
AdditionalRefrigerant(oz/ft)
MaxPipeLength(ft)²
PipeLength(noadd'lRefrigerant,ft) Max
Elevation(ft)
CassetteGrille- PT-QCHW0 or PT-UQC
OptionalAccessories(soldseparately):
Simple Controller with Mode (White) - PREMTC00U
MultiSITE CRC1/CRC1+Thermostat‐PREMTBVC0/PREMTBVC1
PI‐485‐PMNFP14A1
Ventilation³Kit‐PTVK430
Wi-FI Module - PWFMDD200
LowAmbientWindBaffle(Coolingoperationto-4°F)‐
49
89
2,800 ~ 14,000 ~ 15,500
10.05
9
12.6
2.43
0.88
LC128HV4
7
335 / 283 / 247
49/52
2.47
82
ZLABGP01A
15
12.3
0 - 118
10.4
1.05
36/35/32
10.05
25
19.4
988
0.22
Outdoor Unit (ODU) - LUU127HV Indoor Unit (IDU) - LCN128HV4
3,400 ~ 11,100 ~ 12,400
40
31
1.19
9.0
66
1/4 / 1/4
3/8 / 3/8
SB_SZ_Cassette_LC128HV4_2019_02_06_140520
Ceiling Cassette Single Zone