Single Zone Submittal Sheet

Date:
JobName/Location:
PONo.:
Architect:
Engr:
GC:
Rep:
For:
File
A
pp
roval
Mech:
Resubmit
Other
Tag#:
(Company)
(ProjectManager)
ArtCool™SingleZoneInverter
LA120HSV4
Page1of3
SBArtCoolMirrorLA120HSV40215
Forcontinualproductdevelopment,LGreservestherighttochangespecificationswithoutnotice.
©LGElectronicsU.S.A.,Inc.,EnglewoodCliffs,NJ.Allrightsreserved.“LGLife’sGood”isaregisteredtrademarkofLGCorp./www.lghvac.com
Performan ce:
Capacity(Btu/h)
11,200
SEER
21.5
EER
12.5
Cooling:
Heating:
Capacity(Btu/h)
13,300
HSPF
11.0
CoolingNominalTestConditions: HeatingNominalTestConditions:
Indoor:
80°FDB/67°FWB
Indoor:
70°FDB/60°FWB
Outdoor:
95°FDB/75°FWB
Outdoor:
47°FDB/43°FWB
Electrical:
MCA(A )
10
MOP(A)
15
FanMotor(A)
0.40
OutdoorUnit:
CoolingRatedAmps(A)
8.7
HeatingRatedAmps(A)
8.7
IndoorUnit:
CoolingPowerInput(kW)
0.90
HeatingPowerInput(kW)
1.00
Piping:
LiquidLine(in,OD)
1/4
AdditionalRefrigerant(oz/ft)
0.22
MaxElevation(ft)
32.8
PipingLengt h(noadd'lrefrigerant,ft)
41.0
PowerSupply(V¹/H z/Ø)
208230/60/1
Min/MaxPipeLength(ft)²
6.6/65.6
Compressor(A)
8.3
VaporLine(in,OD)
3/8
Features:
OperatingRange:
OutdoorUnit:
IndoorUnit:
UnitData:
RefrigerantType
R410A
RefrigerantCha rge(lbs)
2.21
Fan:
Notes:
1.Acceptableoperangvoltage:187V‐253V.
2.Pipinglengthsareequivalent.
3.SoundPressurelevelsaretestedinananechoicchamberunderISOStandard1996.
4.Allcommunicaon/powercabletobeminimum18AWG,4conductor,stranded,shieldedandmust
complywithapplicablelocalandnationalcode.
5.SeeEngineeringManualforsensible
andlatentcapacies.
6.Powerwiringcablesizemustcomplywiththeapplicablelocalandnaonalcode.
7.Theindoorunitcomeswithadryheliumcharge.
8.Thisdataisrated0abovesealevel,with24.6ofrefrigerantlineanda0leveldierence
betweenoutdoorandindoorunits.

9.MustfollowinstallaoninstruconsintheapplicableLGinstallaonmanual.
ODUType
Propeller
IDUType
CrossFlow
Motor/Drive
BrushlessDigitallyControlled/Direct
Dehumidification(pts/hr)
2.3
RefrigerantControl
EEV
HeatExchangerCoating
GoldFin™
ODUNetUnitWeight(lbs)
75
ODUShippingWeight(lbs)
79
IDUNetUnitWeight(lbs)
24
IDUShippingWeight(lbs)
29
FanSpeeds(Fan/Cooling/Heating)
6/6/6
Quantity(ODU+IDU)
1+1
IDUAirFlowH/M/L(CFM)
353/272/191
ODUMaxAirFlowRate(CFM )
1,165
Cooling(°FDB)
14118
Heating(°FWB)
465
Cooling(°FWB)
5365
Heating(°FDB)
6086
ODUSoundPressureMax(±3dB(A)) ³
45
IDUSoundPressure(H/M/L/Sleep)(±3dB(A))³
39/33/23/19
PowerSupply(V¹/Hz/Ø)
208230/60/1
OptionalAccessories(soldseparately):
LGProgrammableThermostat‐PREMTB10U
IndoorUnit(IDU)LAN120HSV4OutdoorUnit(ODU)LSU120HSV4
SEER‐SeasonalEnergyEfficiencyRatioEER‐EnergyEfficiencyRatio
HSPF‐HeatingSeasonalPerformanceFactor
MOP‐MaximumO vercurrentProtection MCA‐MinimumCircuitAmpacity
•4Wayautoswing
•24Houron/offmer
•Autorestart
•Autochangeover
•Builtinlowambient
standard,downto14°F
(coolingmode)
•Jetcool/Jetheat
•3MMicroProtectionFilter
•Selfcleaningindoorcoil
•Sleepmode
•Ultraquietoperaon
•Coolingonlyfunction
•Chaoswind
•CondensateSensor
Connection
•Energysaving
•Inverter(variablespeed
compressor)
•IDUcompatiblewithMultiF
ODUs
DryCon tactforthirdpartythermostat‐PDRYCB 300
PI485‐PMNFP14A0
Foracompletelistofavailableaccessories,contactyourLGrepresentative.

Summary of content (3 pages)