Single zone Art Cool™ Mirror WALL Mounted Engineering Manual 3/4, 1, and 1-1/2 Tons Models: LA090HSV4 LA120HSV4 LA180HSV4
Proprietary Data Notice This document, as well as all reports, illustrations, data, information, and other materials are the property of LG Electronics U.S.A., Inc., and are disclosed by LG Electronics U.S.A., Inc. only in confidence. This document is for design purposes only. A summary list of safety precautions is on page 4. For more technical materials such as submittals, catalogs, installation, owner’s, and service manuals, visit www.lghvac.com. For continual product development, LG Electronics U.S.
About LG Electronics, Inc. LG Electronics, Inc. is a global leader and technology innovator in consumer electronics, mobile communications, and home appliances. LG Electronics, Inc. comprises five business units— Home Entertainment, Mobile Communications, Air Conditioning, Business Solutions, and Home Appliance. LG is one of the world’s leading producers of flat panel televisions, audio and video products, mobile handsets, air conditioners, and washing machines.
Table of Contents Introduction...................................................................................... 5 Accessories.......................................................................................... 26 Architectural Appeal................................................................... 6 Performance Data......................................................................... 31 Cooling Capacity................................................................................
Introduction “Architectural Appeal” on page 6
Architectural Appeal Convergence of Technological Innovation with Flexibility and Style Benefits of Single Zone Art Cool Mirror Wall-Mounted System • Available in 9,000 - 18,000 Btu/h • Inverter technology Art Cool™ Mirror Wall Mounted Engineering Manual • All-season use - heat pump models for both cooling and heating capabilities • Operating range for outdoor units of 14°F to 118°F (DB) in cooling and -4°F to 65°F (WB) in heating • Operating range for indoor units of 53°F to 75°F (WB) in cooling and 60°
Product data “Product Features and Benefits” on page 8 “Unit Nomenclature” on page 9 “General Data” on page 10 “Electrical Data” on page 11 “Outdoor Unit Dimensions” on page 14 “Indoor Unit Dimensions” on page 16 “Acoustic Data” on page 18 “Refrigerant Flow Diagram” on page 20 “Indoor Unit Wiring Diagram” on page 22 “Outdoor Unit Wiring Diagram” on page 24 “Accessories” on page 26
Product Features and Benefits Art Cool™ Mirror Wall Mounted Engineering Manual Single Zone Art Cool™ Mirror Wall Mount Single zone systems are equipped with inverter components that offer superior load matching and long piping installation. The product works for optimizing power consumption in residential and small office buildings. Utilizing multiple indoor wall mount units each with custom temperature controls allow for precise temperature settings in each zone of the building.
Unit Nomenclature Single Zone Wall Mount Indoor and Outdoor Units LA N 090 HSV 4 Family LA= Art Cool Premier / Gallery / Mirror LS= High Efficiency Wall Mount / Standard / Mega Type N = Indoor Wall Mount Unit U = Outdoor Heat Pump Unit Product Data Nominal Capacity (Nominal cooling capacity in Btu/h) 090/091 = 9,000 120/121 = 12,000 180/181 = 18,000 240 = 24,000 300/307 = 30,000 360 = 36,000 Indoor/Outdoor Product HEV = Mega HXV = Mega 115V HYV = Art Cool Premier HVP = Art Cool Gallery HSV = Art Coo
General Data Art Cool Mirror Pairing Table The following table shows the available outdoor and indoor units, along with the factory provided controller.
General Data Table 2: Single Zone Art Cool Mirror System Specifications. LA090HSV4 (LAN090HSV4/LSU090HSV4) LA120HSV4 (LAN120HSV4/LSU120HSV4) LA180HSV4 (LAN180HSV4/LSU180HSV4) 8,856 (82%) 7,452 (69%) 7,236 (67%) 13.29 21.5 10.8 10,906 (82%) 9,177 (69%) 8,911 (67%) 12.5 21.5 11.0 208-230/60/1 18,040 (82%) 15,180 (69%) 14,740 (67%) 12.58 20.5 9.7 1,023 ~ 9,000 ~ 12,625 0.68 1,023 ~ 10,800 ~ 17,061 0.70 4.51 1,023 ~ 11,200 ~ 13,785 0.90 1,023 ~ 13,300 ~ 22,178 1.0 3.90 3,070 ~ 18,200 ~ 29,515 1.
Electrical Data Art Cool™ Mirror Wall Mounted Engineering Manual Table 3: Single-Zone Art Cool Mirror System Electrical Data Table. Model Number Nominal Tons Compressor Qty. Compressor (A) Cool/Heat Fan Qty. LA090HSV4 3/4 1 8.3/8.3 1 0.40 LA120HSV4 1 1 8.3/8.3 1 LA180HSV4 1-1/2 1 14.6/14.6 1 Voltage tolerance is ±10%. Maximum allowable voltage unbalance is 2%. MCA = Minimum Circuit Ampacity. 12 | Product Data ODU Fan (A) IDU Fan (A) MCA(A) MOP(A) 0.40 10 15 0.40 0.
Functions, Controls, Options Airflow Air Purifying Functions Controllers Other Special Function Kit 1 2 Thermistor Primary washable filters. Secondary filters.
Outdoor Unit Dimensions LSU090HSV4, LSU120HSV4 Discharge Air Grille 30-5/16 4-3/16 6-3/32 13-15/16 11-5/16 5-3/4 4 2-3/32 1 10-15/16 3 5 2-7/8 2 8-3/32 10-1/2 9-3/8 21-1/2 Ø18-5/16 20-7/8 Art Cool™ Mirror Wall Mounted Engineering Manual 22 Center of gravity [Unit : inch ] 19-15/16 14 | Product Data Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved.
Outdoor Unit Dimensions LSU180HSV4 34-1/4 6-5/16 14-3/16 12-19/32 21-1/2 Item No. 1 2 3 4 5 6 Part Name Discharge air grille 12-5/8 5-7/8 2-3/16 13-1/8 Product Data 21-1/8 3-1/8 2 15-7/16 13-3/4 31-1/2 30-7/8 Ø 20-7/8 Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp.
Indoor Unit Dimensions LAN090HSV4, LAN120HSV4 3 2 11-1/4 8-1/16 2-3/8 Art Cool™ Mirror Wall Mounted Engineering Manual 34-13/16 1-3/4 2-3/16 2 1 1-3/4 15/16 2-5/16 6-5/16 4 Place a level on raised tab Unit Outline 17-3/8 17-3/8 Return Air Grille for piping and cables Ø2-9/16 Ø2-9/16 Left rear piping 5-1/8 6-15/16 16 | Product Data 5 Right rear piping 3-11/16 8-1/2 [Unit : Inch] Due to our policy of continuous product innovation, some specifications may change without notification.
Indoor Unit Dimensions LAN180HSV4 40-9/16 3 2-1/16 2-1/16 12-3/4 9-11/16 1-13/16 2 1 Place a level on raised tab Unit Outline 18-1/8 Product Data 1-3/4 2-9/16 Return Air Grille 22-7/16 4 Ø2-9/16 Left rear piping Measuring Tape 2-1/8 4-1/8 2-11/16 Measuring Tape Hanger Right rear piping Ø2-9/16 8-1/8 Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved.
Outdoor Unit Acoustic Data • Measurements are taken 3.28 ft away from the front of the unit. • Sound pressure levels are measured in dB(A) with a tolerance of ±3. • Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745. • Sound level will vary depending on a range of factors including the construction (acoustic absorption coefficient) of a particular room in which the unit was installed.
Indoor Unit Acoustic Data Figure 3: Indoor Unit Sound Levels • • • • Measurements are taken 3.28 ft away from the front of the unit. Sound pressure levels are measured in dB(A) with a tolerance of ±3. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745. Sound level will vary depending on a range of factors including the construction (acoustic absorption coefficient) of a particular room in which the unit was installed.
Refrigerant Flow Diagrams LSU/LAN090HSV4, LSU/LAN120HSV4 Indoor Unit Outdoor Unit FIELD PIPI N G (Ø 1/ 4” Copper Tubing) 2-Way Valve Liquid Side Art Cool™ Mirror Wall Mounted Engineering Manual TH2 M TH1 He at Exchanger (Evaporator) TH4 EEV TH6 TH3 TH5 Heat Exchanger (Condenser) M FIELD PIPI N G (Ø 3/ 8” Copper Tubing) 3- Wa y Valve Reve rsing Valve TH7 Gas Side Accumulator TH8 Compressor 20 Thermistor Description TH1 Indoor air temperature thermistor TH2 Evaporator inlet temperat
Refrigerant Flow Diagrams LSU/LSN180HSV4 Indoor Unit Outdoor Unit FIELD PIPIN G (Ø 3/ 8” Copper Tubing) 2-Way Valve Liqui d Side TH2 M TH1 He at Exchanger (Ev aporator) TH4 EEV TH6 Heat Exchanger (Condenser) M TH3 TH5 FIEL D PIPI N G (Ø 5/ 8” Copper Tubing) 3- Way Valve Reve rsing Valve TH7 Accumulator TH8 Compresso r Thermistor Description TH1 Indoor air temperature thermistor TH2 Evaporator inlet temperature thermistor TH3 Evaporator middle temperature thermistor TH4 Evaporator ou
Wiring Diagram Art Cool™ Mirror Wall Mounted Engineering Manual LAN090HSV4, LAN120HSV4 Auxiliary heater relay kit is not available on single-zone wall-mounted models. 22 | Product Data Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp.
Wiring Diagram LAN180HSV4 Product Data Auxiliary heater relay kit is not available on single-zone wall-mounted models. Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp.
Wiring Diagram Art Cool™ Mirror Wall Mounted Engineering Manual LSU090HSV4, LSU120HSV4 : Factory Wiring : Field Wiring : Optional 24 | Product Data Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp.
Wiring Diagram LSU180HSV4 Product Data Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp.
Accessories Table 7: Optional Zone Controllers. Zone Controller Name Art Cool™ Mirror Wall Mounted Engineering Manual Simple Controller with mode selection Simple Controller without mode selection Model No. PQRCVCL0Q Max Wire Case Color Length (ft) Black PQRCVCL0QW White PQRCHCA0Q Black PQRCHCA0QW Description 164 Allows control of indoor unit on/off, operation mode, fan speed, and temperature setpoint for up to 16 indoor units.
Accessories Table 9: Speciality Application Devices. Speciality Application Device Name Model No.
Accessories Table 10: Summary Data—Central Controllers (Connect to Optional PI-485 Terminals Internet A, Internet B). Art Cool™ Mirror Wall Mounted Engineering Manual Central Controller Name No. of Binary Devices Systems Devices Comm Power, per per Comm per Comm Bus Signals Input/ Conn Controller Bus Bus Ports Output Model No.
Accessories LG Monitoring View (LGMV) Diagnostic Software and Cable (PRCTSL1 and PRCTFE1) LGMV software allows the service technician or commissioning agent to connect a computer USB port to the outdoor unit main printed circuit board (PCB) using an accessory cable without the need for a separate interface device.
Art Cool™ Mirror Wall Mounted Engineering Manual 30 | Product Data Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp.
PERFORMANCE DATA “Cooling Capacity” on page 32 “Heating Capacity” on page 34 “Air Flow and Temperature Distributions Graphs” on page 35
Performance Data Cooling Capacity LA090HSV4, LA120HSV4 Table 12: LAN090HSV4/LSU090HSV4 Cooling Capacities. Art Cool™ Mirror Wall Mounted Engineering Manual Outdoor Air 64 / 53 Temp. (°F DB) TC SHC 14 23 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 118 122 5.51 5.92 6.00 6.23 6.47 6.70 6.93 7.17 7.40 7.63 7.87 8.10 8.00 7.79 7.58 7.37 7.15 6.96 6.77 6.59 6.40 6.21 5.92 4.44 4.76 4.83 5.02 5.21 5.39 5.58 5.77 5.96 6.14 6.33 6.52 6.44 6.27 6.10 5.93 5.75 5.60 5.45 5.30 5.15 5.00 4.76 PI 0.
Performance Data Cooling Capacity LA180HSV4 Table 14: LAN180HSV4/LSU180HSV4 Cooling Capacities. Outdoor Air 64 / 53 Temp. (°F DB) TC SHC 11.14 11.96 12.13 12.60 13.08 13.55 14.02 14.49 14.96 15.44 15.91 16.38 16.17 15.75 15.33 14.91 14.46 14.08 13.70 13.32 12.94 12.56 11.96 8.97 9.63 9.77 10.15 10.53 10.91 11.29 11.67 12.05 12.43 12.81 13.19 13.02 12.68 12.34 12.00 11.64 11.33 11.03 10.72 10.42 10.11 9.63 PI 0.61 0.61 0.62 0.67 0.72 0.76 0.81 0.85 0.90 0.95 0.99 1.04 1.07 1.11 1.19 1.24 1.28 1.30 1.32 1.
Performance Data Heating Capacity LA090HSV4, LA120HSV4, LA180HSV4 Table 15: LAN090HSV4/LSU090HSV4 Heating Capacities. Outdoor Air Temp. Art Cool™ Mirror Wall Mounted Engineering Manual °F DB °F WB -3 0 6 10 16 19 24 32 41 43 47 53 59 64 70 75 -4 -1 5 9 14 17 23 30 38 40 43 50 53 57 61 65 Indoor Air Temperature (°F DB/ °F WB) TC 60 5.51 6.00 6.35 6.62 6.83 6.97 7.65 9.17 10.52 10.86 11.36 11.48 11.74 11.99 12.22 12.39 PI 0.47 0.51 0.54 0.55 0.56 0.58 0.60 0.65 0.69 0.70 0.71 0.72 0.73 0.74 0.75 0.
Performance Data Air Flow and Temperature Distributions Graphs LAN090HSV4 Cooling Heating Discharge angle:45° Discharge angle:50° Air velocity [ft/s] Air velocity [ft/s] 8.9ft 8.9ft 6.6ft 6.6ft 3.9 3.3 3.3 4.0ft 2.5 1.6 16.4ft 13.1ft 9.8ft 6.6ft 0ft 3.3ft Te mperature [˚F] 4.0ft 2.5 1.6 0ft 16.4ft 13.1ft 9.8ft 6.6ft 3.3ft 0ft Te mperature [˚F] 8.9ft 8.9ft 6.6ft 13.1ft 9.8ft 6.6ft 3.3ft 0ft 0ft 16.4ft 13.1ft Performance Data 16.4ft 4.0ft 82.4 84.2 75.2 77 6.
Performance Data Air Flow and Temperature Distributions Graphs LAN180HSV4 Cooling Heating Discharge angle:45° Discharge angle:50° Art Cool™ Mirror Wall Mounted Engineering Manual Air velocity [ft/s] Air velocity [ft/s] 4.9 1.6 26.2ft 23ft 19.7ft 16.4ft 13.1ft 9.8ft 3.3 2.5 6.6ft 8.9ft 6.6ft 6.6ft 4.9 4.0ft 4.1 3.3ft 8.9ft 0ft 0ft Te mperature [˚F] 8.9ft 1.6 26.2ft 23ft 19.7ft 16.4ft 13.1ft 3.3 2.5 9.8ft 6.6ft 4.0ft 4.1 3.3ft 0ft Te mperature [˚F] 8.9ft 6.6ft 26.
Application Guidelines “Equipment Selection Procedure” on page 38 “Building Ventilation Design Guide” on page 40 “Placement Considerations” on page 42
Equipment Selection Procedure Cooling/Heating Correction Factors For Single Zone Art Cool Mirror systems, calculate the equivalent length of the liquid line from the outdoor unit to the indoor unit. Also, determine the elevation difference of the indoor unit above or below the outdoor unit. Find corresponding cooling or heating capacity correction factors as shown in Figures 5 through 8.
Equipment Selection Procedure Figure 7: LA180HSV4 Cooling Coefficient Factor. Cooling Capacity(%) 100 95 18k 90 20(65.6) Application Guidelines 7.5(24.6) 30(98.4) To tal Pipe Length[m(ft)] Figure 8: LA180HSV4 Heating Coefficient Factor. Heating Capacity(%) 100 95 7.5(24.6) 18k 20(65.6) 30(98.4) To tal Pipe Length[m(ft)] Due to our policy of continuous product innovation, some specifications may change without notification. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ.
Building Ventilation Design Guide Building Ventilation Design Guide Art Cool™ Mirror Wall Mounted Engineering Manual ASHRAE 62.1 and local codes specify the minimum volume of outdoor air that must be provided to an occupied space. Outdoor air is required to minimize adverse health effects, and it provides acceptable indoor air quality for building occupants. The three methods of accomplishing this with single zone systems are summarized here.
Building Ventilation Design Guide Method 2: Unconditioned Outdoor Air (Non-Ducted, Natural Ventilation) Natural ventilation devices, such as operable windows or louvers may be used to ventilate the building when local code permits. The open area of a window or the free area of a louver must meet the minimum percentage of the net occupied floor area (Figure 10). Advantages • Occupants control the volume of the ventilation air manually.
Placement Considerations Selecting the Best Location DANGER To avoid the possibility of fire, do not install the unit in an area where combustible gas may generate, flow, stagnate, or leak. Failure to do so will cause serious bodily injury or death. Art Cool™ Mirror Wall Mounted Engineering Manual Install a fence to prevent vermin from crawling into the unit or unauthorized individuals from accessing it.
Placement Considerations Indoor Unit Clearance/Outdoor Unit Installation Indoor Unit Best Location Figure 12: Single Zone Indoor Unit Clearance Requirements. Follow recommended best practices when choosing an indoor location for the single zone indoor unit. • Use a metal detector to locate studs in the walls. Anchor unit following stud location, to prevent damage to the wall. • Clearance gap between any wall or enclosure and the left or right side of the unit must be greater than 4 inches (Figure 12).
Placement Considerations Outdoor Unit Clearances Minimum Clearance Requirements for Single-Zone Art Cool Mirror Systems Proper clearance for the outdoor unit coil is critical for proper unit operation. When installing the outdoor unit, consider service, inlet and outlet and minimum allowable space requirements as illustrated in the diagrams below. Specific clearance requirements in the diagram below are for the single-zone Art Cool Mirror wall mount systems.
Refrigerant Piping Design & Layout Best Practices “Refrigerant Piping Design” on page 46 "Selecting Field-Supplied Copper Tubing" on page 47 "Refrigerant Piping System Layout" on page 48 “Piping Connections” on page 50 "Electrical Connections" on page 52 “Mechanical Specifications” on page 54 "Acronyms" on page 55
Refrigerant Piping Design Design Guideline Summary/Selecting Field-Supplied Copper Tubing Device Connection Limitations Figure 18: Art Cool Mirror System Layout. Unit = Feet Single-zone systems consist of one outdoor unit and one indoor unit. One of the most critical elements of a single zone system is the refrigerant piping. Table 19 lists pipe length limits that must be followed in the design of a Single Zone Art Cool Mirror refrigerant pipe system.
Refrigerant Piping Design Selecting Field-Supplied Copper Tubing Figure 19: Coiled Expansion Loops and Offsets. L L R L R Loop Small Tubing U-bend (<3/4 in.) Table 21: Radii of Coiled Expansion Loops and Developed Lengths of Expansion Offsets.
Installation & Layout Best Practices Refrigerant Piping System Layout Obstacles Figure 20: Installing Piping Above and Below an Obstacle. Art Cool™ Mirror Wall Mounted Engineering Manual When an obstacle, such as an I-beam or concrete T, is in the path of the planned refrigerant pipe run, it is best practice to route the pipe over the obstacle. If adequate space is not available to route the insulated pipe over the obstacle, then route the pipe under the obstacle.
Installation & Layout Best Practices Refrigerant Piping System Layout Pipe Sleeves at Penetrations LG requires that all pipe penetrations through walls, floors, and pipes buried underground be properly insulated and routed through an appropriate wall sleeve of sufficient size to prevent compression of refrigerant pipe insulation and free movement of the pipe within the sleeve. Underground refrigerant pipe shall be routed inside a protective sleeve to prevent insulation deterioration See Figure 24.
Installation & Layout Best Practices Refrigerant Piping System Layout Single Zone Art Cool Mirror Outdoor Unit Connections Art Cool™ Mirror Wall Mounted Engineering Manual 1. Remove the tubing cover from the unit by loosening the fastening screws (Figures 26 and 27). 2. Align the center of the refrigerant pipe and corresponding connection as shown in Figures 29 and 30. 3. Place a couple of drops of refrigerant oil on the opening rim of the flare before assembling. Ensure you do not add any contaminants.
Installation & Layout Best Practices Refrigerant Piping System Layout Installation of Refrigerant Piping / Brazing Practices It is imperative to keep the piping system free of contaminants and debris such as copper burrs, slag, or carbon dust during installation. Refrigerant Piping System Insulation All refrigerant piping, field-provided isolation ball valves, service valves, and long radius elbows shall be completely insulated using closed cell pipe insulation.
Electrical Connections Art Cool™ Mirror Wall Mounted Engineering Manual Outdoor Electrical Connection Figure 32: LSU090HSV4/LSU120HSV4 Outdoor Unit Electrical Connection. 1. Remove the control cover from the unit by loosening the fastening screw (Figures 32 and 33). 2. Take off the caps on the conduit panel. 3. Connect both the power supply and low voltage lines to the corresponding terminals on the terminal block (see Figure 35 and Figure 36). 4. Be sure to ground the unit by following local codes. 5.
Technical Data “Mechanical Specifications” on page 54 “Acronyms” on page 55
Mechanical Specifications Single Zone Art Cool Mirror Art Cool™ Mirror Wall Mounted Engineering Manual General LG Single Zone Art Cool Mirror systems are comprised of a single outdoor unit connected to a single indoor unit with a single refrigerant circuit. These single zone systems can operate in either cooling or heating mode. These systems are capable of changing mode within a maximum time of three (3) minutes to ensure indoor temperature can be properly maintained.
Acronyms Table 27: Table of Acronyms.
20001747 ISO 9001: 2008 LG ELECTRONICS INC. LG Electronics Commercial Air Conditioning Division 11405 Old Roswell Road Alpharetta, Georgia 30009 www.lg-vrf.com LG Electronics Commercial Products Support 1-888-865-3026 USA Follow the prompts for commercial A/C products.