24 | PRODUCT DATA
Single Zone Art Cool
TM
Mirror Wall Mount Engineering Manual
REFRIGERANT FLOW DIAGRAMS
Refrigerant Flow Diagram for LAN / LSU090, 120HSV5
Thermistor Description PCB Connector
TH1
Indoor air temperature thermistor
CN-TH1 (Indoor)
TH2
Evaporator inlet temperature thermistor
TH3
Evaporator middle temperature thermistor CN-TH3 (Indoor)
TH4
Evaporator outlet temperature thermistor
CN-TH2 (Indoor)
TH5
Water level sensor (optional)
TH6
Outdoor air temperature thermistor
C_PIPE/AIR (Outdoor)
TH7
Condensing temperature thermistor
TH8
Discharge pipe temperature thermistor D_PIPE (Outdoor)
Table 8: Single Zone Art Cool Mirror Wall Mount LA090HSV5, LA120HSV5 Thermistor Details.
Figure 23: Refrigerant Flow Diagram for LA090HSV5, LA120HSV5 Units.
Model Vapor (inch) Liquid (inch)
LA090HSV5, LA120HSV5
Ø 3/8 Ø 1/4
Refrigerant Pipe Connection Port Diameters for LA090HSV5, LA120HSV5.
Table 9: Refrigerant Pipe Connection Port Diameters for LA090HSV5, LA120HSV5.