Owner's Manual
11
INSTALLATION
Installation of the Unit
Space for Outside Air Flow
NOTE
bottom of the unit is well supported,
the top has minimum clearace and the
air inlet louveres have clearance as
shown. Holes from the outside through
to the cavity should be sealed. The
unit should slope down towards
the rear by about 10~15 mm to allow
water formed during operation to drain.
1
Prepare the hole in the wall so that the
Ensure the foam seals are not damaged.
Flash, seal or fill gaps around the inside
and outside to provide satisfactory
appearance and protection against the
weather, insects and rodents.
2
Install the unit into the wall and secure.
●Unit may be supported by a solid frame from
below or by a hanger from a solid overhead
support.
FLASH OR SEAL AROUND EXTERNAL
WALL FRAME OR ARCHITRAVE
STURDY TIMBER
FRAME ALL ROUND
UNIT
DRAIN PIPE
EXTERNAL SUPPORT
FRAME AT BALANCE
POINT OF RAC
Preferred method of installation into
a timber framed wall, partition or window.
ALTERNATIVELY, BRACKETS
AS ILLUSTRATED BELOW
MAY BE USED.
TIMBER FRAMED
WALL OR PARTITION
100 mm minimum
AIR IN
AIR IN
AIR OUT
OPTION A
100mm
100mm
LOUVRE
FRONT
45° BRICK CUT AWAY
TO CLEAR LOUVRES
45° BRICK CUT AWAY
TO CLEAR LOUVRES
BRICK
WALL
AIR INAIR IN
BRICK
WALL
AIR OUT
TOP
VIEW
OPTION B
The Foam
(Around the unit)
CAUTION
●Use an assistant to help lift the unit and set
it in place. Lifting and maneuvering the unit
by yourself could result injury.