The wall you select should be strong and solid enough
to prevent vibration.
1 Mount the installation plate on the wall with type "A"
screws. If mounting the unit on a concrete wall, use
anchor bolts.
- Mount the installation plate horizontally by aligning
the centerline using Horizontal meter .
2 Measure the wall and mark the centerline.
It is also important to use caution concerning the
location of the installation plate. Routing of the wiring
to power outlets is through the walls typically. Drilling
the hole through the wall for piping connections must
be done safely.
Installation Plate
Chassis
hook
Type “A” Screws
Fixing installation Plate
• Drill the piping hole with a Ø55mm hole core drill. Drill
the piping hole at either the right or the left with the hole
slightly slanted to the outdoor side.
5-7mm
(3/16"~5/16")
Indoor
WALL
Outdoor
Drill a Hole in the Wall