Datasheet

Installation5RMI0-02A
95
Inverter Single
Select the best Location
Outdoor unit
- If an awning is built over the unit to prevent
direct sunlight or rain exposure, make sure that heat
radiation from the condenser is not restricted.
- Ensure that the space around the back and sides is
more than 300mm. The space in front of the unit should
be more than 700mm of space.
- Do not place animals and plants in the path of the warm
air.
- Take the weight of the air conditioner into
account and select a place where noise and vibration
are minimum.
- Select a place where the warm air and noise from the
air conditioner do not disturb
neighbors.
Indoor unit
- There should not be any heat or steam near the unit.
- Select a place where there are no obstacles around of the unit.
- Make sure that condensation drainage can be conveniently routed away.
- Do not install near a doorway.
- Ensure that the interval between a wall and the left
(or right) of the unit is more than 500mm. The unit
should be installed as high as possible on the wall,
allowing a minimum of 200mm from ceiling.
- Use a metal detector to locate studs to prevent
unnecessary damage to the wall.
* The feature can be changed according to a type of
model.
More than 200
More than
500
More than 2,300
More than
500
(Unit : mm)
More than
300
More than
300
Sunroof
Fence or
obstacles
More than
700
More than
600
(Unit : mm)
• Install the indoor unit on the wall where the height from the floor is more than 2,300mm.
CAUTION
• Install the installation plate on a flat wall. If a wall is uneven, please make the surface of wall flat. Otherwise, it may
cause abnormal noise.
• Ensure that the interval between a wall and the left of the unit is more than 500mm. Otherwise. it may be difficult to
take out/in a air filter.
WARNING