Datasheet
Refrigerant cycle diagram 5RMI0-02A
50
Inverter Single
Indoor Unit Outdoor Unit
Heat
Exchanger
(Evaporator)
Heat
Exchanger
(Condenser)
EEV
Compressor
Accumulator
Gas Side
3-Way Valve
2-Way Valve
Liquid Side
Cooling
Heating
Reversing Valve
Th2
Th1
Th5
Th4
Th3
* EEV : Electronic Expansion Valve.
LOC Description PCB Connector
Th1 Thermistor for indoor air temperature CH_TH1(INDOOR)
Th2 Thermistor for evaporating temperature CH_TH2(INDOOR)
Th3 Thermistor for discharge pipe temperature CN_TH2(OUTDOOR)
Th4 Thermistor for condensing temperature
CN_TH1(OUTDOOR)
Th5 Thermistor for outdoor air temperature
Models: AS-W0963WB0(G09WL), AS-W1263WB0(G12WL)
6. Refrigerant cycle diagram