Datasheet
5RMI0-02A
18
Inverter Single
Note :
1. Capacities are based on the following conditions :
Cooling : - Indoor Temperature 27°C DB/19°C WB
- Outdoor Temperature 35°C DB/24°C WB
Heating: - Indoor Temperature 20°C DB/15°C WB
- Outdoor Temperature 7°C DB/6°C WB
Piping Length - Interconnecting Piping Length 7.5m
- Level Difference of Zero
2. Wiring cable size must comply with the applicable local and national code.
3. The specification may be subject to change without prior notice for purpose of improvement
Models
AS-W1862WR0(D18RL)
AS-W1862EF0(P18EL)
Heat transfer (sorce / sink) -
Air to Air
Type of appliance -
Cooling/Heating (Inverter heatpump)
Cooling Capacity kW
5.0
Heating Capacity kW
5.8
Low Temp. Heating Capacity (-7°C) kW
3.8
Power Input Cooling/Heating W
1,562 / 1,611
Running Current Cooling/Heating A
7.2 / 7.5
Starting Current Cooling/Heating A
7.2 / 7.5
Max Current Cooling/Heating A
9.0 / 9.5
SEER W/W
6.1
SCOP W/W
4.0
Energy efficiency class*
Cooling/Heating -
A++ / A+*A(more efficient),
G(less efficient)
Annual energy consumption Cooling/Heating kWh
287 / 1,435
Power Supply Ø / V / Hz
1 / 220-240 / 50
Air Flow Rate
Indoor,Max m³/min
19
Outdoor,Max m³/min
32
Moisture Removal l/h
1.8
Sound Pressure Level
Indoor,H/M/L/Sleep* dB(A)±3
42 / 40 / 35 / 29
Outdoor,Max dB(A)±3
51
Sound Power Level
Indoor,Max dB(A)±3
60
Outdoor,Max dB(A)±3
65
Refrigerant & Charge (at 7.5 m) g
R410A, 1,150
Additional Refrigerant charge g/m
20
Compressor
Model -
5RS132XCA21
Motor Type -
Brushless DC Motor
O.L.P. name -
-
Fan(Indoor)
Type -
Cross Flow Fan
Motor Type -
BLDC
Motor Output W
20
Fan(Outdoor)
Type -
Propeller, Fan
Motor Type -
BLDC
Motor Output W
43
Circuit Breaker A
20
Power Supply Cable N x mm²
3*1.5
Power and Transmission Cable N x mm² N x mm²
4*1.0
Piping Connextions
Liquid Side mm
6.35
Gas Side mm
12.7
Drain Hose(O.D, I.D) mm
21.5, 16.0
Dimensions
Indoor (WⅹHⅹD) mm
1090*330*248
Outdoor (WⅹHⅹD) mm
770*545*288
Net Weight
Indoor kg
14.5
Outdoor kg
34
Operation Range
Cooling(Outdoor) °C
-10 ~ 48
Heating(Outdoor) °C
-10 ~ 24
Piping Length (Min / Max) m
- / 20
Max Elevation Difference m
10
Conversion Formula
kW = Btu/h x 0.0002931
cfm = CMM x 35.3