Datasheet

Outdoor unit
P18EL UL2
D18RL UL2
Indoor unit
/ P18EL NS2
/ D18RL NS2
Function (indicate if present)
If function includes heating: Indicate the heating
season the information relates to. Indicated values
should relate to one heating season at a time. Include
at least the heating season 'Average'.
cooling Y Average (mandatory) Y
heating Y Warmer (if designated) N
Colder (if designated) N
Item symbol value valueunit Item symbol unit
Design load Seasonal efficiency
cooling Pdesignc
5.0
kW cooling SEER 6.1 -
heating / Average Pdesignh
4.1
kW heating / Average SCOP/A 4.0 -
heating / Warmer Pdesignh x,x kW heating / Warmer SCOP/W x,x -
heating / Colder Pdesignh x,x kW heating / Colder SCOP/C x,x -
Declared capacity* for cooling, at indoor temperature
27(19)ºC and outdoor temperature Tj
Declared Energy efficiency ratio* for cooling, at indoor
temperature 27(19)ºC and outdoor temperature Tj
Tj=35ºC Pdc
5.0
kW Tj=35ºC EERd
3.1
-
Tj=30ºC Pdc
3.7
kW Tj=30ºC EERd
5.0
-
Tj=25ºC Pdc
2.4
kW Tj=25ºC EERd
7.4
-
Tj=20ºC Pdc
1.1
kW Tj=20ºC EERd
9.2
-
Declared capacity* for heating / Average climate, at indoor
temperature 20ºC and outdoor temperature Tj
Declared Coefficient of performance* for heating /
Average climate, at indoor temperature 20ºC and outdoor
temperature Tj
Tj=-7ºC Pdh
4.1
kW Tj=-7ºC COPd
2.6
-
Tj=2ºC Pdh
2.5
kW Tj=2ºC COPd
3.8
-
Tj=7ºC Pdh
1.6
kW Tj=7ºC COPd
4.7
-
Tj=12ºC Pdh
0.7
kW Tj=12ºC COPd
5.4
-
Tj=bivalent temperature Pdh
4.6
kW Tj=bivalent temperature COPd
2.5
-
Tj=operating limit Pdh
4.1
kW Tj=operating limit COPd
2.6
-
Declared capacity* for heating / Warmer climate, at indoor
temperature 20ºC and outdoor temperature Tj
Declared Coefficient of performance* / Warmer climate,
at indoor temperature 20ºC and outdoor temperature Tj
Tj=2ºC Pdh x,x kW Tj=2ºC COPd x,x -
Tj=7ºC Pdh x,x kW Tj=7ºC COPd x,x -
Tj=12ºC Pdh x,x kW Tj=12ºC COPd x,x -
Tj=bivalent temperature Pdh x,x kW Tj=bivalent temperature COPd x,x -
Tj=operating limit Pdh x,x kW Tj=operating limit COPd x,x -
Declared capacity* for heating / Colder climate, at indoor
temperature 20ºC and outdoor temperature Tj
Declared Coefficient of performance* / Colder climate, at
indoor temperature 20ºC and outdoor temperature Tj
Tj=-7ºC Pdh x,x kW Tj=-7ºC COPd x,x -
Tj=2ºC Pdh x,x kW Tj=2ºC COPd x,x -
Tj=7ºC Pdh x,x kW Tj=7ºC COPd x,x -
Tj=12ºC Pdh x,x kW Tj=12ºC COPd x,x -
Tj=bivalent temperature Pdh x,x kW Tj=bivalent temperature COPd x,x -
Tj=operating limit Pdh x,x kW Tj=operating limit COPd x,x -
Tj=-15ºC Pdh x,x kW Tj=-15ºC COPd x,x -
Bivalent temperature Operating limit temperature
heating / Average Tbiv -7 ºC heating / Average Tol -10 ºC
heating / Warmer Tbiv x ºC heating / Warmer Tol x ºC
heating / Colder Tbiv x ºC heating / Colder Tol x ºC
Cycling interval capacity Cycling interval efficiency
for cooling Pcycc x,x kW for cooling EERcyc x,x -
for heating Pcych x,x kW for heating COPcyc
x,x
-
Degradation co-efficient
cooling**
Cdc 0.25 -
Degradation co-efficient
heating**
Cdh 0.25 -
Electric power input in power modes other than 'active
mode'
Annual electricity consumption
off mode P
OFF
0.002 kW cooling Q
CE
287
kWh/a
standby mode P
SB
0.002 kW heating / Average Q
HE
1435
kWh/a
thermostat-off mode P
TO
0.035 kW heating / Warmer Q
HE
x
kWh/a
crankcase heater mode P
CK
0 kW heating / Colder Q
HE
x
kWh/a
Capacity control (indicate one of three options) Other items
fixed N
Sound power level
(indoor/outdoor)
L
WA
60/
65
dB(A)
staged N Global warming potential GWP 1975
kgCO2 eq.
variable Y Rated air flow (indoor/outdoor) -
1084/
1528
m3/h
Contact details for obtaining
more information
Christianna PAPAZAHARIOU
Internal communicator - Energy & environment regulations expert
,LGElectronics
Paris Nord II – 117 avenue des Nations
BP 59372 Villepinte – 95942 Roissy CDG Cedex
chris.papazahariou@lge.com
Tel. +33 1 49 89 57 41 , +33 6 83 077 455
*= For staged capacity units, two values divided by a slash (‘/’) will be declared in each box in the section “Declared
capacity of the unit” and "declared EER/COP" of the unit.
**= If default Cd=0,25 is chosen then (results from) cycling tests are not required. Otherwise either the heating or cooling
cycling test value is required.
Models : AS-W1862WR0(D18RL), AS-W1862EF0(P18EL)
Inverter Single
161