Datasheet

Installation5RMI0-02A
115
Inverter Single
The wall you select should be strong and solid enough
to prevent vibration
1. Mount the installation plate on the wall with type "A"
screws. If mounting the unit on a concrete wall, use
anchor bolts.
- Mount the installation plate horizontally by aligning
the centerline using Horizontal meter .
2. Measure the wall and mark the centerline. It is also
important to use caution concerning the location of the
installation plate. Routing of the wiring to power
outlets is through the walls typically. Drilling the hole
through the wall for piping connections must be done
safely.
Installation Plate
Chassis Hook
Type "A" Screws
Fixing Installation Plate
• Drill the piping hole with a ø65mm hole core drill. Drill
the piping hole at either the right or the left with the hole
slightly slanted to the outdoor side.
5-7mm
(3/16"~5/16")
Indoor
WALL
Outdoor
Drill a Hole in the Wall