Datasheet
Installation 5RMI0-02A
104
Inverter Single
Indoor
Connect the cable to the indoor unit by connecting the
wires to the terminals on the control board individually
according to the outdoor unit connection. (Ensure that the
color of the wires of the outdoor unit and the terminal No.
are the same as those of the indoor unit.)
The power connecting cable with indoor and
outdoor unit should be selected according to the
following national wiring regulations.
The supply cords of parts of appliances for outdoor
use shall not be lighter than polychloroprene
sheathed flexible cord.
(code designation 60245 IEC 57, H05RN-F)
Indoor
- Connect the wires to the terminals on the control board
individually.
- Secure the cable onto the control board with the cord
clamp.
- Use a recognized circuit breaker between the power
source and the unit.
A disconnecting device to adequately disconnect all
supply lines must be fitted.
- The circuit diagram is a subject to change without
notice.
- The earth wire should be longer than the common
wires.
- When installing, refer to the circuit diagram on the
chassis cover.
- Connect the wires firmly so that they may not be pulled
out easily.
- Connect the wires according to color codes, referring to
the wiring diagram.
The power cord connected to unit should be
selected according to the following national wiring
regulations.
The supply cords of parts of appliances for outdoor
use shall not be lighter than polychloroprene
sheathed flexible cord.
(code designation 60245 IEC 57, H05RN-F)
CAUTION
CAUTION
35±5mm
GN/YL
20mm
10±3mm
45±5mm
GN/YL
20mm
10±3mm
Connecting the Cables
(mm
2
)
NOMINAL CROSS -
SECTIONAL AREA
Grade
2.5kW~3.5kW
1.0
(mm
2
)
NOMINAL CROSS
-SECTIONAL AREA
Grade
2.5kW~3.5kW
1.0
Circuit Breaker(A)
Grade
2.5kW~3.5kW
15