Install the air conditioner in the location that satisfies the following conditions.
The place shall easily bear a load exceeding four times the indoor units weight.
The place shall be able to inspect the unit as the figure.
The place where the unit shall be leveled.
The place shall allow easy water drainage.(Suitable dimension H is necessary to get a slope to drain as figure.)
The place shall easily connect with the outdoor unit.
The place where the unit is not affected by an electrical noise.
The place where air circulation in the room will be good .
There should not be any heat source or steam near the unit.
Read completely, then follow step by step.
Top view
(unit: mm)
H
Front view
600600
Front
Inspection hole
(600X600)
1000
Control box
Installation
Selection of the best location
CAUTION : In case that the unit is installed near the sea, the installation parts
may be corroded by salt, The installation parts (and the unit) should be taken
appropriate anti-corrosion measures.