Install Manual
14
6HUYHU&RQQHFWLRQDQG%DWWHU\6WDWXV&KHFN
IoT Hub Connection String: Enter the unique string provided to you in order to access the
Azure IoT Hub (cloud server).
The string format is as follows:
HostName=emashub.azure-devices.net;DeviceId=XXXX;SharedAccessKey=OOOO=
* For more information on how to obtain strings, refer to Section 3.2.1.2 Obtaining IoT Hub
String.
Server Connection Check: Check the server connection.
Battery Status: Check if the product has diagnosed any issues.
When the server connection is complete, click the “Next” button.
50':L)L'LVFRQQHFWLRQ
Disable Wi-Fi in the same way that you connected Wi-Fi in Section 50':L)L'LUHFW
Connection
Disconnect Wi-Fi
When the server connection is complete, click the “Complete” button.
3.2.2.10 Connect to RESU Monitor to Check Product Registration
After product installation via RMD is complete, check if the product has been registered on the
server by selecting “RESU Monitor” below. (https://resumonitor.lgensol.com)
When you log-in, you can check
the product registration as shown
in the picture.
3.3 Cable Connections
1
2
3
&DEOH&RQ¿JXUDWLRQ
Section A Section B Section D Section E
Section C
1. Section A: Inverter communication ports including CAN/RS485 and enable lines
2. Section B: DIP switch for setting communication termination resistor.
3. Section C: DIP switch for setting primary/secondary packs.
4. Section D: Do not connect the internal communication ports
5. Section E: Battery power ports including positive/negative pole and ground
(POS: power terminal plus, NEG: power terminal minus, GND: ground)
3.3.2 Guide for cable connection and setting the DIP switch
1 2 3 4 5 6
1. Section A: Inverter communication
ports
a) First, connect the enable ground
wire to Terminal 2.
b) Connect the enable 12V positive
line to Terminal 1.
c) Select the method that matches the
inverter communication method
in the part marked. If the inverter
uses RS485, connect the RS485
(A+, B-) lines to Terminals 3 and 4.
If inverter uses the CAN method,
connect the CAN (high, low) lines
to Terminals 5 and 6.
ဵ5HIHUWR6HFWLRQ3.3.3 Spring Terminal Blocks, when choosing the communication cable
and cable sheath for peeling.
2. Section B: DIP switch for setting
communication termination resistor
of primary/secondary packs
Lower the DIP switch (Communication
Termination resistor) all downwards for
single pack.
ဵ:KHQ\RXLQVWDOOWZRSDFNVUHIHU
to the appendix about setting for
communication termination resistor.
3. Section C: DIP switch for setting
primary/secondary packs
Raise all DIP switch upward when
you want to use as a primary pack.
And also, when you want to use as a
secondary pack, lower the switch on
the right side only when viewed from
the front