Datasheet

RESU16H Prime
Product Specification (1/2)
Electrical Characteristics
Usable Energy
1)
16.0 kWh @77
°F (25°C)
Voltage Range
Charge
420 ~ 450
V
DC
Discharge
350 ~ 410
V
DC
Max. Charge/Discharge Current
16.6A@420V/
20A@350V
Max. Charge/Discharge
Power
7 kW
Peak
Power (only discharging)
2)
11 kW for 10 sec.
Peak Current (only discharging)
32.8A
for 10 sec.
Communication Interface
RS485/CAN
DC
Protection
Circuit Breaker, Fuse, DCDC
converter
Connection Method
Spring Type Connector
User interface
LEDs for Normal and Fault operation
Protection Features
Over Voltage / Over Current /
short
circuit / Reverse Polarity
Scalability
(Total Energy, Max. Charge/Discharge Power)
Max. 2 in parallel
(32.0 kWh @77
°F (25°C), 14kW)
Operating Conditions
Installation Location
Indoor / Outdoor, Stand only
Operating Temperature
14 ~
122°F (-10 ~ 50°C)
Operating
Temperature (Recommended)
59 ~ 86
°F (15 ~ 30°C)
Storage
Temperature (At shipping state)
-
22 to 140°F (-30 to 60°
C), acceptable
for 7 days in total
-
4 to 113°F (-20 to 45°C), acceptable
for the first 6 months
-
4 to 86°F (-20 to 30°C), acceptable
for 7th month~12th month
Humidity
5%~95%
Altitude
Max. 6,562ft (2,000m)
Cooling Strategy
Natural Convection
Certification
Safety
Cell
UL1642
Battery Pack
UL1973 / CE / RCM /
IEC 62619
Emissions
FCC
Hazardous Materials Classification
Class 9
Transportation
UN38.3 (UNDOT)
Ingress Rating
IP55
Test Conditions - Temperature 77°F (25°C), at the beginning of life
Usable Energy is measured under specific condition from LGC(0.3CCCV/0.3CC)
Product specification may change without notice
1) DOD 100%. DC/DC converter one way efficiency 97.5%. Ambient 77°F (25°C)
2) Peak Current excludes repeated short duration (less than 10 sec. of current pattern).