ENGLISH РУССКИЙ ЯЗЫК OWNER’S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. TYPE : Floor Standing Type KZ.O.02.0561 The equipment complies with requirements of the Technical Regulation, in terms of restrictions for the use of certain dangerous substances in electrical and electronic equipment. www.lg.
Floor Standing Type Air Conditioner Ownerʼs Manual TABLE OF CONTENTS Safety Precautions................................................................................................................3 Operating Instructions..........................................................................................................7 - Features and Specifications ..............................................................................................7 - Indoor Unit Controls and Indicators.................
Safety Precautions Safety Precautions WARNING This symbol indicates the possibility of death or serious injury. CAUTION This symbol indicates the possibility of injury or damage. n Meanings of symbols used in this manual are as shown below. Be sure not to do. Be sure to follow the instruction. WARNING n Installation Do not use a defective or underrated circuit breaker. Use this appliance on a dedicated circuit. • There is risk of fire or electric shock.
Safety Precautions For installation, always contact the dealer or an Authorized Service Center. • There is risk of fire, electric shock, explosion, or injury. Do not install the product on a defective installation stand. • It may cause injury, accident, or damage to the product. Be sure the installation area does not deteriorate with age. • If the base collapses, the air conditioner could fall with it, causing property damage, product failure, and personal injury.
Safety Precautions Ventilate the product from time to time when operating it together with a stove, etc. ENGLISH • There is risk of fire or electric shock. Turn the main power off when cleaning or maintaining the product. • There is risk of electric shock. When the product is not be used for a long time, disconnect the power supply plug or turn off the breaker. • There is risk of product damage or failure, or unintended operation.
Safety Precautions Do not step on or put anyting on the product. (outdoor units) • There is risk of personal injury and failure of product. Do not drink the water drained from the product. • It is not sanitary and could cause serious health issues. Always insert the filter securely. Clean the filter every two weeks or more often if necessary. Do not insert hands or other objects through the air inlet or outlet while the product is operated.
Operating Instructions Operating Instructions 1. Design for cooling and heating 5. 2 cooling/heating speeds 2. Super energy efficiency 6. Removable air filter 3. Micom control 7. Anti-Bacteria filter 4. Whisper quiet operation 8.
Operating Instructions Indoor Unit Controls and Indicators 12 7 5 6 13 10 14 ROOM TEMP. SET TEMP. DUCT L H OUT DOOR MODE 15 8 9 2 3 4 11 1 (Heat Pump & Electric Heater Model) 1. START/STOP BUTTON Operation starts when this button is pressed and stops when the button is pressed again. 2. OPERATION MODE SELECTION BUTTON Used to select the operation Mode. 3. ROOM TEMPERATURE SETTING BUTTONS Used to select the room temperature. 4.
Operating Instructions • Each time the Operation Mode Selection Button is pressed, the Operation Mode is shifted in the arrow direction. MODE ROOM TEMP. ROOM TEMP. SET TEMP. A/CL L H L OUT DOOR Fan Operation ROOM TEMP. SET TEMP. A/CL ROOM TEMP. SET TEMP. A/CL H A/CL L OUT DOOR L H OUT DOOR Cooling Operation OUT DOOR Soft Dry Operation Heating Operation How to use the Fan speed Button • Each time the Fan speed Button is pressed, the Fan speed is shifted in the arrow direction.
Operating Instructions Cooling Operation Mode 1 Press the Start/Stop Button. 2 Select Cooling Operation. Press the Operation Mode Selection Button. MODE ROOM TEMP. SET TEMP. A/CL L H OUT DOOR 3 Set the temperature lower than the room temperature. The temperature can be set within a range of 18°C~30°C by 1°C. ROOM TEMP. SET TEMP. MODE A/CL L H OUT DOOR • Press the 4 or button To raise the temperature. To lower the temperature. Set the Fan Speed.
Operating Instructions ENGLISH Soft Dry Operation 1 Press the Start/Stop Button. 2 Select Soft Dry Operation. Press the Operation Mode Selection Button. ROOM TEMP. SET TEMP. A/CL L OUT DOOR 3 Set the temperature lower than the room temperature. The temperature can be set within a range of 18°C~30°C by 1°C. ROOM TEMP. SET TEMP. A/CL L OUT DOOR • Press the or button To raise the temperature. To lower the temperature.
Operating Instructions Heating Operation Mode 1 Press the Start/Stop Button. 2 Select heating Operation. Press the Operation Mode Selection Button. MODE ROOM TEMP. SET TEMP. A/CL L H OUT DOOR 3 Set the temperature upper than the room temperature. The temperature can be set within a range of 16°C~30°C by 1°C. ROOM TEMP. SET TEMP. MODE A/CL L H OUT DOOR • Press the 4 or button Set the Fan Speed. MODE • Each time the Button is pressed, the Fan Speed mode is shifted.
Operating Instructions ENGLISH Electric Heater Operation Mode 1 Press the Start/Stop Button. 2 Select heating+ E/heater Operation. ∂ Press the Operation Mode Selection Button to select heating Operation. ∑ Press the E/Heater Operation Button. (When the unit operates in heating mode). ROOM TEMP. SET TEMP. A/CL L H OUT DOOR 3 Set the temperature upper than the room temperature. The temperature can be set within a range of 16°C~30°C by 1°C. ROOM TEMP. SET TEMP.
Operating Instructions OFF Timer Setting Procedure(OFF TIMER Setting, or CANCEL) 1 2 Press the Start/Stop Button. Press the Timer Button. ROOM TEMP. SET TEMP. L H L H OUT DOOR OUT DOOR • If you press the button, the selected off timer is displayed as follows;ʼ • If you select ʻ 3 ʼ, the Off Timer function will be cancelled. When you finish the Off Timer setting, the Timer indicator lights off. ROOM TEMP. SET TEMP.
Operating Instructions ENGLISH Fan Operation Mode 1 Press the Start/Stop Button. 2 Select Fan Operation. Press the Operation Mode Selection Button. MODE ROOM TEMP. A/CL L H OUT DOOR 3 Set the Fan Speed. MODE • Each time the Button is pressed, the Fan Speed mode is shifted. Airflow Direction Procedure Adjust air flow direction manually by moving the horizontal or vertical louvers with hand.
Operating Instructions Child Lock Operation Procedure 1 Press Temperature up and fan speed setting buttons simultaneously for 3 seconds, then unit will respond with beep sound. MODE ROOM TEMP. SET TEMP. ROOM TEMP. SET TEMP. A/CL L A/CL H L A/CL H L OUT DOOR OUT DOOR After 3 seconds, it will shift. After 3 seconds, it will shift.
Maintenance and Service Maintenance and Service ENGLISH CAUTION: Before performing any maintenance, turn off the main power to the system. During the season Cleaning of the air filters. Recommended about once every two weeks Cleaning of the air cleaner. Recommended about once every three months Remove the Air Filter. Take hold of the tab and pull slightly forward to remove the filter. Remove the Air Cleaner. Take hold of the tab and pull slightly forward to remove the air cleaner. Clean.
Maintenance and Service Troubleshooting Check the following points before requesting repairs or service.... If the malfunction persist, please contact your dealer. Case Does not operate. Explanation • Have you made a mistake in timer operation? • Has the fuse blown or has the circuit breaker been tripped? • Is the power Switch at Off? • Is the unit at the starting of Heating Operation? If yes, Hot-start is activating. • Is the unit in the Deicing? If yes, wait for finishing the Deicing.