Installation Guide
16 INSTALLATION
Checking Adjustments
1 
Place the level diagonally on the oven rack, 
and check each direction for level.
a
. Then check 
direction 
b
.
2 
that the rack is level, 
adjust the leveling legs with a wrench.
Connecting Gas
Providing Adequate Gas Supply
to operate at a pressure 
of 5" of water column on natural gas or 10" of 
water column on LP.
type of gas for which it is configured.
gas. When using this range on LP gas, 
conversion must be made by a qualified LP 
installer before attempting to operate the range.
gas supplied to the regulator must be between 
5" and 13" of water column.
ssure supplied to the 
regulator must be between 10" and 13" of water 
column. When checking for correct operation of 
the regulator, the inlet pressure must be at least 
1" more than the operating (manifold) pressure 
as given above.
gulator located at the inlet of the 
range must remain in the supply line regardless 
of which type of gas is being used.
connect the range to the gas supply line should 
have an I.D. of 5/8" and a maximum length of 5 
feet. In Canada, flexible connectors must be 
single wall metal connectors less than 6 feet in 
length.
Connecting the Range to Gas
WARNING
the gas supply system by 
closing its individual shut-off valve during any 
pressure testing of the gas supply system at test 
pressures equal to or less than 1/2 psi (3.5 kPa).
must be disconnected from the gas supply 
piping system during any pressure testing of 
that system at test pressures in excess of 1/2 psi 
(3.5 kPa).
removing the old range and leave it off until the 
new hook-up has been completed.
stricts movement of the 
range, the use of a CSA International-certified 
flexible metal appliance connector should be 
used unless local codes require a hard-piped 
connection.
installed in an accessible 
location in the gas piping external to the 
appliance for the purpose of turning on or 
shutting off gas to the appliance.
ector when installing a 
new range.
joint sealant on all external threads.
1 
Install a male 1/2" or 3/4" flare union adapter 
to the NPT internal thread of the manual shut-
off valve, taking care to back-up the shut-off 
valve to keep it from turning.
2 
Install a male 1/2" flare union adapter to the 
1/2" NPT internal thread at the inlet of the 
pressure regulator. Use a backup wrench on 
the pressure regulator fitting to prevent 
damage.
is in the open position.
a
b