Measurement Guide
MINIMUM DIMENSIONS
*  30” (76.2 cm) minimum clearance 
between the top of the cooking 
surface and the bottom of an 
unprotected wood or metal cabinet; 
or 24” (60.9 cm) minimum when 
bottom of wood or metal cabinet 
is protected by not less than 
1/4”(6.4 cm) ame retardant 
millboard covered with not less than 
no. 28 MSG sheet steel, 0.015” 
(0.381 mm) stainless steel, 0.024” 
(0.610 mm) aluminum or 0.020” 
(0.508mm) copper.
** 15” (38.1 cm) minimum  
between countertop and  
adjacent cabinet bottom.
3" (7.6 cm)
24"
(60.9 cm)
24"
(60.9 cm)
36"
(91.4 cm)
29.8"
(75.7 cm)
25"
(63.5 cm)
36"
(91.4 cm)
3" (7.6 cm)
Acceptable 
electrical 
outlet area
Normal counter 
top depth
Counter 
top height
Cabinet 
opening
A
= 30" (76.2 cm) For U.S.A 
15" (38 cm)
11" (28 cm)
2.5" (6.3 cm)
2.5"
(6.3 cm)
9"
(23 cm)
4"
(10 cm)
9"
(23 cm)
4"
(10 cm)
6"
(15.2 cm)
5"
(13 cm)
6"
(15.2 cm)
Wall
Center
Cabinet
DIMENSIONS AND CLEARANCES
This appliance must be installed and 
grounded on a branch circuit by a qualied 
technician in accordance with the National 
Electrical code ANSI/NFPA NO. 70 - latest 
edition. 
All wiring should conform to Local and NEC 
codes. This range requires a single-phase, 3 
wire, A.C 120/208 V or 120/240 V 60 Hz 
electrical system. Use only a 3-conductor or 
a 4-conductor UL - listed range cord with 
closed-loop terminals, open-end spade lugs 
with upturned ends or similar termination. 
Do not install the power cord without a 
strain relief. 
A range cord rated at 40 amps with 
120/240 minimum volt range is required. 
If a 50 amp range cord is used, it should 
be marked for use with 13/8" diameter 
connection openings. This appliance may 
be connected by means of a conduit or 
power cord. If a conduit is being used, check 
the Owners Manual for 3 wire conduit 
connections or 4 wire conduit connections.
▲
! Warning
• Allow 2 to 3 ft (61.0 cm to 91.4 cm) of 
slack in the line so that the range can be 
moved if servicing is ever necessary.
• The power supply cord and plug should 
not be modied. If it will not t the 
outlet, have a proper outlet Installed by 
a qualied electrician.
• Using an extension cord to connect the 
power is prohibited. Connect the power 
cord and plug directly.
• Electrical ground is required on this 
appliance.
• Make sure that the power cord is not 
pinched by the range or heavy objects. 
Failure to do so can result in serious 
burns or electrical shock.
Specified power-supply-cord kit rating
Range rating, watts
Specified 
rating of 
power 
supply-
cord kit, 
amperes
Diameter (inches) 
of Range 
connection 
Opening
120/240 
volts
3-wire
120/208 
volts
3-wire
Power 
cord
Conduit
 8,750 - 
16,500
16,501 - 
22,500
 7,801 - 
12,500
12,501 - 
18,500
40 or 50A
50
1 
3
/
8
" 
1 
3
/
4
"
1 
1
/
8
" 
1 
3
/
8
"
4 Wire 
receptacle  
(14-50R)
3 Wire 
receptacle 
(10-50R)
ELECTRICAL REQUIREMENTS
30"
(76.2 cm)
36"
(91.4 cm)
**15"
(38.1 cm)
*30" (76.2 cm)
Minimum
LRE3193* 
QUICK INSTALL & 
CLEARANCES
For full installation directions/clearances 
please refer to the corresponding 
User Manual and Installation Guide.
DIMENSIONS/CLEARANCES/WEIGHT
Product Weight  167 lbs
Shipping Weight  191 lbs
Product Dimensions  
(with backguard and handle)  29-7/8" x 47-1/8" x 28-1/4" 
(in) (W x H x D) 
Cabinet Dimensions (in) (W x H x D)   30" x 36" x 25"
Height to Cooking Surface (in)  36"
Upper Oven 
Interior Dimensions  24-13/16" x 22-1/4" x 19-11/16" 
(in) (W x H x D) 
Drawer Dimensions  
(in) (W x H x D)  22-3/16" x 4-1/2" x 16-3/8"
Carton Dimensions  
(in) (W x H x D)  33-11/16" x 50-7/8" x 30-9/16"
POWER/RATINGS
Amp Rating at 208V  40A
Amp Rating at 240V  40A
KW Rating at 208V  10.9kW
KW Rating at 240V  14.5kW
LG Brand_Electric Ranges Fin_1.indd 10 8/21/17 4:23 PM