Instructions / Assembly
15
INSTALLATION
ENGLISH
WARNING
•
Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack 
in the line so that the range can be moved if 
servicing is ever necessary.
•
The power supply cord and plug should 
not be modified. If it will not fit the outlet, 
have a proper outlet Installed by a qualified 
electrician.
•
Using an extension cord to connect the 
power is prohibited. Connect the power 
cord and plug directly.
•
Electrical ground is required on this 
appliance.
•
Make sure that the power cord is not 
pinched by the range or heavy objects. 
Failure to do so can result in serious burns or 
electrical shock.
Specified power-supply-cord kit rating
Range rating, watts
Specified 
rating of 
power 
supply-
cord kit, 
amperes
Diameter (inches) 
of Range 
connection 
Opening
120/240 
volts
3-wire
120/208 
volts
3-wire
Power 
cord
Conduit
 8,750 - 
16,500
16,501 - 
22,500
 7,801 - 
12,500
12,501 - 
18,500
40 or 50A
50
1 
3
/
8
" 
1 
3
/
4
"
1 
1
/
8
" 
1 
3
/
8
"
3, 4 - Wire electrical wall Receptacle
4 Wire receptacle (14-50R)
3 Wire receptacle (10-50R)
Connecting the Power Cord
The rear access cover must be removed. Loosen the 
two screws with a screwdriver. The terminal block will 
then be accessible.
Access cover
Use the cord/conduit connection plate to install the 
power cord or conduit. Leave the connection plate 
as installed for power cord installations. Remove the 
connection plate for conduit installations and use the 
smaller 1
1
/
8
 in. (2.8 cm) conduit hole instead of the 
1
3
/
8
 in. (3.5 cm) power cord hole.
Remove the Conduit connection plate
1
1
/
8
"
 (2.8 cm) Conduit
1
3
/
8
"
 (3.5 cm) Cord
For power cord installations, hook the strain relief 
over the 1
3
/
8
 in. (3.5 cm) power cord hole located 
below the rear of the oven. Insert the power cord 
through the strain relief and tighten it.
Conduit 
connection 
plate
Power cord
Assembling power cord strain relief at the 1
3
/
8
" opening
For conduit installations, insert the conduit strain 
relief in the 1
1
/
8
 in. (2.8 cm) conduit hole. Then install 
the conduit through the body of the strain relief and 
fasten the strain relief with its ring.
Cord/
Conduit 
connection 
plate
Conduit
Ring
Body
Assembling conduit cord strain relief at the 1
1
/
8
" opening